- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Starting Mininet Topology - PASS
- 7.12 Check whether the flow count is bigger than 74 - PASS
- 7.13 Check whether all flow status are ADDED - PASS
- 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.18 Stopping Mininet - PASS
- 7.19 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Starting Mininet Topology - PASS
- 8.12 Check whether the flow count is bigger than 212 - PASS
FAIL
- Flow count looks wrong: 102
- 8.13 Check whether all flow status are ADDED - PASS
- 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
FAIL
- Flow count looks wrong: 17
- 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
FAIL
- Flow count looks wrong: 17
- 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
FAIL
- Flow count looks wrong: 17
- 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
FAIL
- Flow count looks wrong: 17
- 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS
FAIL
- IP connectivity failed
- 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS
FAIL
- IP connectivity failed
- 8.20 Stopping Mininet - PASS
- 8.21 Copying karaf logs - PASS
...
- 76.1 Apply cell to environment - PASS
- 76.2 Uninstalling Atomix - PASS
- 76.3 Uninstalling ONOS package - PASS
- 76.4 Installing Atomix - PASS
- 76.5 Installing ONOS package - PASS
- 76.6 Set up ONOS secure SSH - PASS
- 76.7 Checking ONOS service - PASS
- 76.8 Starting ONOS CLI sessions - PASS
- 76.9 Checking ONOS nodes - PASS
- 76.10 Checking ONOS applications - PASS
- 76.11 Starting Mininet Topology - PASS
- 76.12 Check whether the flow count is bigger than 74 - PASS
- 76.13 Check whether all flow status are ADDED - PASS
- 76.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 76.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 76.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS
- 76.17 Stopping Mininet - PASS
- 76.18 Copying karaf logs - PASS
Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 77.1 Apply cell to environment - PASS
- 77.2 Uninstalling Atomix - PASS
- 77.3 Uninstalling ONOS package - PASS
- 77.4 Installing Atomix - PASS
- 77.5 Installing ONOS package - PASS
- 77.6 Set up ONOS secure SSH - PASS
- 77.7 Checking ONOS service - PASS
- 77.8 Starting ONOS CLI sessions - PASS
- 77.9 Checking ONOS nodes - PASS
- 77.10 Checking ONOS applications - PASS
- 77.11 Starting Mininet Topology - PASS
- 77.12 Check whether the flow count is bigger than 74 - PASS
- 77.13 Check whether all flow status are ADDED - PASS
- 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
FAIL
- Flow count looks wrong: 17
- 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS
- 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS
- 77.18 Stopping Mininet - PASS