...
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Starting Mininet Topology - PASS
- 36.12 Check whether the flow count is bigger than 74 - PASS
- 36.13 Check whether all flow status are ADDED - PASS
- 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS
- 36.17 Stopping Mininet - PASS
- 36.18 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Starting Mininet Topology - PASS
- 37.12 Check whether the flow count is bigger than 74 - PASS
- 37.13 Check whether all flow status are ADDED - PASS
- 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
FAIL
- Flow count looks wrong: 17
- 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS
- 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS
FAIL
- IP connectivity failed
- 37.18 Stopping Mininet - PASS
- 37.19 Copying karaf logs - PASS
...