If you want to get only the "<optical-channel>" of "<component>", the content of get-components-op-channel is:
Code Block |
---|
language | xml |
---|
linenumbers | true |
---|
|
<?xml version="1.0"?>
<get xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<filter>
<components xmlns="http://openconfig.net/yang/platform">
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device" />
</component>
</components>
</filter>
</get> |
The output is out-get-components-op-channel:
Code Block |
---|
language | xml |
---|
linenumbers | true |
---|
collapse | true |
---|
|
<rpc-reply xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" xmlns:nc="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="urn:uuid:c9220366-76bd-43ba-ad3c-13e1b7014e21">
<data>
<components xmlns="http://openconfig.net/yang/platform">
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>0</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe1</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>0</frequency>
<target-output-power>0.0</target-output-power>
<line-port>oe1</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194700000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe2</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>0</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe2</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>0</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe3</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>0</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe3</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194700000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe4</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194750000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe4</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194700000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe5</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194750000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe5</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194700000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe6</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194750000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe6</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194700000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe7</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194750000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe7</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194700000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe8</line-port>
</config>
</optical-channel>
</component>
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194750000</frequency>
<target-output-power>-10.0</target-output-power>
<line-port>oe8</line-port>
</config>
</optical-channel>
</component>
</components>
</data>
</rpc-reply> |
If you want to get the "<config>" nodes only where the frequency is 194750000 and the line-port is oe1, the content of get-config-nodes is:
Code Block |
---|
language | xml |
---|
linenumbers | true |
---|
|
<?xml version="1.0"?>
<get xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<filter>
<components xmlns="http://openconfig.net/yang/platform">
<component>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<line-port>oe1</line-port>
<frequency>194750000</frequency>
</config>
</optical-channel>
</component>
</components>
</filter>
</get>
</get> |
The output is is out-get-config-nodes:
Code Block |
---|
language | xml |
---|
linenumbers | true |
---|
|
<nc:rpc-reply xmlns:nc="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="urn:uuid:703f18cc-512f-411c-8b8d-f07a87b4797f">
<data xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<components xmlns="http://openconfig.net/yang/platform">
<component>
<name>oe1/2</name>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194750000</frequency>
<target-output-power>-5.1</target-output-power>
<line-port>oe1</line-port>
</config>
</optical-channel>
</component>
</components>
</data>
</nc:rpc-reply> |
...
If you want to change the target-output-power value as 0dBm instead of the default -5.1 dBm where "<name>" ID is "oe1/2", the content of file is set-target-output-power :
Code Block |
---|
language | xml |
---|
linenumbers | true |
---|
|
<?xml version="1.0"?>
<edit-config xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<target><running/></target>
<config>
<components xmlns="http://openconfig.net/yang/platform">
<component>
<name>oe1/2</name>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<target-output-power>0</target-output-power>
</config>
</optical-channel>
</component>
</components>
</config>
</edit-config>
|
...
Then we request the "<config>" nodes again to check this operation, where the frequency is 194750000 and the line-port is oe1 . The output is changed:using get-config-nodes:
As you the following output illustrates, the target-output-power is changed from -5.1 to 0.
Code Block |
---|
language | xml |
---|
linenumbers | true |
---|
|
<nc:rpc-reply xmlns:nc="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="urn:uuid:ca069e53-020a-4201-a9d3-53f4e5534bec">
<data xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<components xmlns="http://openconfig.net/yang/platform">
<component>
<name>oe1/2</name>
<optical-channel xmlns="http://openconfig.net/yang/terminal-device">
<config>
<frequency>194750000</frequency>
<target-output-power>0.0</target-output-power>
<line-port>oe1</line-port>
</config>
</optical-channel>
</component>
</components>
</data>
</nc:rpc-reply> |