Fix: resolve NPE caused by null portId of instancePort at two events

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spineand 1 nodes. - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling ONOS package - PASS (tick)
  • 1.4 Creating ONOS package - PASS (tick)
  • 1.5 Installing ONOS package - PASS (tick)
  • 1.6 Set up ONOS secure SSH - PASS (tick)
  • 1.7 Checking ONOS service - PASS (tick)
  • 1.8 Starting ONOS CLI sessions - PASS (tick)
  • 1.9 Starting Mininet Topology - PASS (tick)
  • 1.10 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.11 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.12 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.13 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.14 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.15 Pushing new configuration - No Result (warning)
  • 1.16 Pushing new configuration - No Result (warning)
  • 1.17 Check whether the flow count is bigger than 140 - PASS (tick)
  • 1.18 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.22 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE1 - PASS (tick)
  • 1.23 Stopping Mininet - PASS (tick)
  • 1.24 Copying karaf logs - PASS (tick)

Case 2: Bridging and Routing sanity test with 4x4 Leaf-spineand 1 nodes. - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling ONOS package - PASS (tick)
  • 2.3 Creating ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Set up ONOS secure SSH - PASS (tick)
  • 2.6 Checking ONOS service - PASS (tick)
  • 2.7 Starting ONOS CLI sessions - PASS (tick)
  • 2.8 Starting Mininet Topology - PASS (tick)
  • 2.9 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.10 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 2.11 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.12 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.13 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.14 Pushing new configuration - No Result (warning)
  • 2.15 Pushing new configuration - No Result (warning)
  • 2.16 Check whether the flow count is bigger than 380 - PASS (tick)
  • 2.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 2.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.21 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE2 - PASS (tick)
  • 2.22 Stopping Mininet - PASS (tick)
  • 2.23 Copying karaf logs - PASS (tick)

Case 3: Bridging and Routing sanity test with single switchand 1 nodes. - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling ONOS package - PASS (tick)
  • 3.3 Creating ONOS package - PASS (tick)
  • 3.4 Installing ONOS package - PASS (tick)
  • 3.5 Set up ONOS secure SSH - PASS (tick)
  • 3.6 Checking ONOS service - PASS (tick)
  • 3.7 Starting ONOS CLI sessions - PASS (tick)
  • 3.8 Starting Mininet Topology - PASS (tick)
  • 3.9 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.10 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 3.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.12 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.13 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.14 Pushing new configuration - No Result (warning)
  • 3.15 Pushing new configuration - No Result (warning)
  • 3.16 Check whether the flow count is bigger than 18 - PASS (tick)
  • 3.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 3.18 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.21 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE3 - PASS (tick)
  • 3.22 Stopping Mininet - PASS (tick)
  • 3.23 Copying karaf logs - PASS (tick)

Case 4: Bridging and Routing sanity test with 2x2 Leaf-spineand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling ONOS package - PASS (tick)
  • 4.3 Creating ONOS package - PASS (tick)
  • 4.4 Installing ONOS package - PASS (tick)
  • 4.5 Set up ONOS secure SSH - PASS (tick)
  • 4.6 Checking ONOS service - PASS (tick)
  • 4.7 Starting ONOS CLI sessions - PASS (tick)
  • 4.8 Starting Mininet Topology - PASS (tick)
  • 4.9 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 4.10 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 4.11 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.12 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.13 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.14 Pushing new configuration - No Result (warning)
  • 4.15 Pushing new configuration - No Result (warning)
  • 4.16 Check whether the flow count is bigger than 140 - FAIL (error)
    • Flow count looks wrong: False
  • 4.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 4.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.21 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE4 - PASS (tick)
  • 4.22 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 4.23 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.24 Removing host configuration - No Result (warning)
  • 4.25 Removing configuration - No Result (warning)
  • 4.26 Removing vlan configuration - No Result (warning)
  • 4.27 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 4.28 Check whether all flow status are ADDED - PASS (tick)
  • 4.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE4_After - PASS (tick)
  • 4.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_After - PASS (tick)
  • 4.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_After - PASS (tick)
  • 4.32 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE4_After - PASS (tick)
  • 4.33 Stopping Mininet - PASS (tick)
  • 4.34 Copying karaf logs - PASS (tick)

Case 5: Bridging and Routing sanity test with 4x4 Leaf-spineand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling ONOS package - PASS (tick)
  • 5.3 Creating ONOS package - PASS (tick)
  • 5.4 Installing ONOS package - PASS (tick)
  • 5.5 Set up ONOS secure SSH - PASS (tick)
  • 5.6 Checking ONOS service - PASS (tick)
  • 5.7 Starting ONOS CLI sessions - PASS (tick)
  • 5.8 Starting Mininet Topology - PASS (tick)
  • 5.9 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong: False
  • 5.10 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 5.11 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.12 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.13 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.14 Pushing new configuration - No Result (warning)
  • 5.15 Pushing new configuration - No Result (warning)
  • 5.16 Check whether the flow count is bigger than 380 - FAIL (error)
    • Flow count looks wrong: False
  • 5.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 5.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.21 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE5 - PASS (tick)
  • 5.22 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 5.23 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 5.24 Removing host configuration - No Result (warning)
  • 5.25 Removing configuration - No Result (warning)
  • 5.26 Removing vlan configuration - No Result (warning)
  • 5.27 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.28 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 5.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE5_After - PASS (tick)
  • 5.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_After - PASS (tick)
  • 5.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_After - PASS (tick)
  • 5.32 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE5_After - PASS (tick)
  • 5.33 Stopping Mininet - PASS (tick)
  • 5.34 Copying karaf logs - PASS (tick)

Case 6: Bridging and Routing sanity test with single switchand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling ONOS package - PASS (tick)
  • 6.3 Creating ONOS package - PASS (tick)
  • 6.4 Installing ONOS package - PASS (tick)
  • 6.5 Set up ONOS secure SSH - PASS (tick)
  • 6.6 Checking ONOS service - PASS (tick)
  • 6.7 Starting ONOS CLI sessions - PASS (tick)
  • 6.8 Starting Mininet Topology - PASS (tick)
  • 6.9 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong: False
  • 6.10 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 6.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.12 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - PASS (tick)
  • 6.13 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - PASS (tick)
  • 6.14 Pushing new configuration - No Result (warning)
  • 6.15 Pushing new configuration - No Result (warning)
  • 6.16 Check whether the flow count is bigger than 20 - FAIL (error)
    • Flow count looks wrong: False
  • 6.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 6.18 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - PASS (tick)
  • 6.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - PASS (tick)
  • 6.21 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE6 - PASS (tick)
  • 6.22 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 6.23 Check number of topology elements - PASS (tick)
  • 6.24 Removing host configuration - No Result (warning)
  • 6.25 Removing configuration - No Result (warning)
  • 6.26 Removing vlan configuration - No Result (warning)
  • 6.27 Check whether the flow count is bigger than 15 - PASS (tick)
  • 6.28 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 6.29 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE6_After - PASS (tick)
  • 6.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6_After - PASS (tick)
  • 6.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6_After - PASS (tick)
  • 6.32 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE6_After - PASS (tick)
  • 6.33 Stopping Mininet - PASS (tick)
  • 6.34 Copying karaf logs - PASS (tick)