SRSwitchFailure at 18 Jan 2020 01:58:50

SRSwitchFailure

commit bf9c996017a7bd2ebd5ffd0d9b15f6ba0f59a2b3 (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey [ray@opennetworking.org]
AuthorDate: Fri Jan 17 09:15:55 2020 -0800
Commit: Ray Milkey [ray@onlab.us]
CommitDate: Fri Jan 17 18:14:30 2020 +0000

bump development libgen version to new SNAPSHOT

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 1.24 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.25 Check whether all flow status are ADDED - PASS (tick)
  • 1.26 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.28 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.29 Stopping Mininet - PASS (tick)
  • 1.30 Copying karaf logs - PASS (tick)

Case 2: Switch Failure test with 4x4 Leaf-spine and 1 Onos - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 2.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 2.23 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.24 Check whether all flow status are ADDED - PASS (tick)
  • 2.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.28 Stopping Mininet - PASS (tick)
  • 2.29 Copying karaf logs - PASS (tick)

Case 4: Switch Failure test with 2x2 Leaf-spine and 3 Onos - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 4.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Failure - FAIL (error)
    • IP connectivity failed
  • 4.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Failure - FAIL (error)
    • IP connectivity failed
  • 4.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Failure - FAIL (error)
    • IP connectivity failed
  • 4.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 4.23 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.24 Check whether all flow status are ADDED - PASS (tick)
  • 4.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.28 Stopping Mininet - PASS (tick)
  • 4.29 Copying karaf logs - PASS (tick)

Case 5: Switch Failure test with 4x4 Leaf-spine and 3 Onos - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Starting Mininet Topology - PASS (tick)
  • 5.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.14 Check whether all flow status are ADDED - PASS (tick)
  • 5.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 5.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 5.23 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.24 Check whether all flow status are ADDED - PASS (tick)
  • 5.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.28 Stopping Mininet - PASS (tick)
  • 5.29 Copying karaf logs - PASS (tick)
  • No labels