FUNCnetCfg at 10 Jun 2016 05:33:49

commit 8e9f8d151070de13be4cb347efe4e4f2f33324a9 (HEAD, origin/master, origin/HEAD, master)
Author: Brian Stanke [bstanke@ciena.com]
AuthorDate: Wed Jun 8 14:48:33 2016 -0400
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Jun 9 17:10:35 2016 +0000

ONOS-2184 - Adding VirtualNetworkTopologyService using Virtual networks.

Case 1: Constructing test variables and building ONOS package - PASS

This test case is mainly for loading from params file, and pull and build the latest ONOS package

  • 1.1 Constructing test variables - PASS (tick)

Case 2: Starting up 7 node(s) ONOS cluster - PASS

Set up ONOS with 7 node(s) ONOS cluster

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Creating ONOS package - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Starting ONOS service - PASS (tick)

Case 20: Add Network configurations to the cluster - FAIL

Add Network Configurations for devices not discovered yet. One device is allowed, the other disallowed.

  • 20.1 Add Net Cfg for switch1 - PASS (tick)
  • 20.2 Add Net Cfg for switch3 - PASS (tick)
  • 20.3 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.

Case 11: Start Mininet topology with OF 1.3 switches - PASS

Start mininet topology with OF 1.3 switches to test intents, exits out if topology did not start correctly

  • 11.1 Starting Mininet topology with OF 1.3 switches - PASS (tick)

Case 21: Check Devices After they initially connect to ONOS - FAIL

  • 21.1 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.
  • 21.2 ONOS should only show devices S1, S2, and S4 - PASS (tick)
  • 21.3 Check device annotations - PASS (tick)

Case 22: Add Network configurations for connected devices to the cluster - FAIL

Add Network Configurations for discovered devices. One device is allowed, the other disallowed.

  • 22.1 Add Net Cfg for switch2 - FAIL (error)
    • Net Cfg for device s2 not correctly set
  • 22.2 Add Net Cfg for switch4 - PASS (tick)
  • 22.3 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.

Case 23: Check Devices after all configurations are set - FAIL

  • 23.1 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.
  • 23.2 ONOS should only show devices S1 and S2 - PASS (tick)
  • 23.3 Check device annotations - FAIL (error)
    • Incorrect annotations for configured devices.

Case 24: Testing removal of configurations - FAIL

  • 24.1 Remove 'allowed' configuration from all devices - FAIL (error)
    • Failed to remove the 'allowed' config key.
  • 24.2 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.
  • 24.3 Delete basic config for s1 and s2 - FAIL (error)
    • Failed to removed S1 and S2 basic config
  • 24.4 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.
  • 24.5 Delete the net config for S3 - PASS (tick)
  • 24.6 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.
  • 24.7 Delete the net config for all devices - PASS (tick)
  • 24.8 Check net config - FAIL (error)
    • Net Cfg is different on some nodes. Some nodes failed to GET netCfg.
  • 24.9 Assert the net config for devices is empty - PASS (tick)
  • No labels