Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 99 Next »

SROnosFailure at 21 Mar 2017 11:47:06

Case 1: ONOS Failure test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Create and Apply cell file - PASS (tick)
  • 1.3 Create and Install ONOS package - PASS (tick)
  • 1.4 Starting ONOS service - PASS (tick)
  • 1.5 Checking if ONOS CLI is ready - PASS (tick)
  • 1.6 Starting Mininet Topology - PASS (tick)
  • 1.7 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 1.8 Check whether all flow status are ADDED - PASS (tick)
  • 1.9 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.10 Connectivity for [u'olt10', u'vsg10'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.11 Connectivity for [u'olt5', u'vsg5'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.12 Killing ONOS instance - FAIL (error)
    • Failed to turn off ONOS Instance
  • 1.13 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.14 Connectivity for [u'olt10', u'vsg10'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.15 Connectivity for [u'olt5', u'vsg5'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.16 Recovering ONOS instance - PASS (tick)
  • 1.17 Checking if ONOS CLI is ready - PASS (tick)
  • 1.18 Checking ONOS nodes - PASS (tick)
  • 1.19 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 1.20 Check whether all flow status are ADDED - PASS (tick)
  • 1.21 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.22 Connectivity for [u'olt10', u'vsg10'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Connectivity for [u'olt5', u'vsg5'] CASE1_Failure - FAIL (error)
    • IP connectivity failed

Case 2: ONOS Failure test with 4x4 Leaf-spine - FAIL

  • 2.1 Create and Apply cell file - PASS (tick)
  • 2.2 Create and Install ONOS package - PASS (tick)
  • 2.3 Starting ONOS service - PASS (tick)
  • 2.4 Checking if ONOS CLI is ready - PASS (tick)
  • 2.5 Starting Mininet Topology - PASS (tick)
  • 2.6 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong: False
  • 2.7 Check whether all flow status are ADDED - PASS (tick)
  • 2.8 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.9 Connectivity for [u'olt10', u'vsg10'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.10 Connectivity for [u'olt5', u'vsg5'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.11 Killing ONOS instance - FAIL (error)
    • Failed to turn off ONOS Instance
  • 2.12 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.13 Connectivity for [u'olt10', u'vsg10'] CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.14 Connectivity for [u'olt5', u'vsg5'] CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.15 Recovering ONOS instance - PASS (tick)
  • 2.16 Checking if ONOS CLI is ready - PASS (tick)
  • 2.17 Checking ONOS nodes - PASS (tick)
  • 2.18 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong: False
  • 2.19 Check whether all flow status are ADDED - PASS (tick)
  • 2.20 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.21 Connectivity for [u'olt10', u'vsg10'] CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.22 Connectivity for [u'olt5', u'vsg5'] CASE3_Recovery - FAIL (error)
    • IP connectivity failed

Case 3: ONOS Failure test with single switch - FAIL

  • 3.1 Create and Apply cell file - PASS (tick)
  • 3.2 Create and Install ONOS package - PASS (tick)
  • 3.3 Starting ONOS service - PASS (tick)
  • 3.4 Checking if ONOS CLI is ready - PASS (tick)
  • 3.5 Starting Mininet Topology - PASS (tick)
  • 3.6 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong: False
  • 3.7 Check whether all flow status are ADDED - PASS (tick)
  • 3.8 Connectivity for [u'h1', u'h2'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.9 Connectivity for [u'olt10', u'vsg10'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.10 Connectivity for [u'olt5', u'vsg5'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.11 Killing ONOS instance - FAIL (error)
    • Failed to turn off ONOS Instance
  • 3.12 Connectivity for [u'h1', u'h2'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.13 Connectivity for [u'olt10', u'vsg10'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.14 Connectivity for [u'olt5', u'vsg5'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.15 Recovering ONOS instance - PASS (tick)
  • 3.16 Checking if ONOS CLI is ready - PASS (tick)
  • 3.17 Checking ONOS nodes - PASS (tick)
  • 3.18 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong: False
  • 3.19 Check whether all flow status are ADDED - PASS (tick)
  • 3.20 Connectivity for [u'h1', u'h2'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.21 Connectivity for [u'olt10', u'vsg10'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.22 Connectivity for [u'olt5', u'vsg5'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • No labels