VPLSBasic at 26 May 2017 00:32:03

commit 6440b09d323525b0392b1bc363da67fc9397466e (HEAD, origin/master, origin/HEAD, master)
Author: Jordan Halterman [jordan@onlab.us]
AuthorDate: Wed May 24 17:48:08 2017 -0700
Commit: Jordan Halterman [jordan@onlab.us]
CommitDate: Thu May 25 17:32:17 2017 -0700

Fix incorrectly spelled DEFAULT_OPERTATION_TIMEOUT_MILLIS constant... Driving me crazy!

Case 1: Setting up test environment - PASS

Setup the test environment including installing ONOS, starting Mininet and ONOScli sessions.

  • 1.1 Create cell file - No Result (warning)
  • 1.2 Applying cell variable to environment - No Result (warning)
  • 1.3 Starting Mininet - PASS (tick)
  • 1.4 Creating ONOS package - PASS (tick)
  • 1.5 Installing ONOS package - PASS (tick)
  • 1.6 Set up ONOS secure SSH - PASS (tick)
  • 1.7 Checking if ONOS is up yet - PASS (tick)
  • 1.8 Starting ONOS CLI sessions - PASS (tick)
  • 1.9 Activate apps defined in the params file - No Result (warning)
  • 1.10 Set ONOS configurations - No Result (warning)
  • 1.11 App Ids check - PASS (tick)

Case 2: - FAIL

  • 2.1 Discover hosts using pings - No Result (warning)
  • 2.2 Load VPLS configurations - PASS (tick)
  • 2.3 Check interface configurations - PASS (tick)
  • 2.4 Check network configurations for vpls application - FAIL (error)
    • Net Cfg not added for vpls
  • 2.5 Check vpls app configurations - FAIL (error)
    • VPLS not configured correctly
  • 2.6 Check connectivity - FAIL (error)
    • Connectivity is not as expected

Case 3: - FAIL

  • 3.1 Remove an interface from a vpls network - No Result (warning)
  • 3.2 Check network configurations for vpls application - FAIL (error)
    • Net Cfg not added for vpls
  • 3.3 Check vpls app configurations - FAIL (error)
    • VPLS not configured correctly
  • 3.4 Check connectivity - FAIL (error)
    • Connectivity is not as expected
  • 3.5 Clean all vpls configurations - No Result (warning)
  • 3.6 Check network configurations for vpls application - PASS (tick)
  • 3.7 Check vpls app configurations - PASS (tick)
  • 3.8 Check connectivity - PASS (tick)
  • 3.9 Create a new vpls network - No Result (warning)
  • 3.10 Check network configurations for vpls application - PASS (tick)
  • 3.11 Check vpls app configurations - PASS (tick)
  • 3.12 Check connectivity - PASS (tick)
  • 3.13 Add interfaces to the network - No Result (warning)
  • 3.14 Check network configurations for vpls application - PASS (tick)
  • 3.15 Check vpls app configurations - PASS (tick)
  • 3.16 Check connectivity - PASS (tick)
  • 3.17 Add MPLS encapsulation to a vpls network - No Result (warning)
  • 3.18 Check network configurations for vpls application - PASS (tick)
  • 3.19 Check vpls app configurations - PASS (tick)
  • 3.20 Check connectivity - FAIL (error)
    • Connectivity is not as expected
  • 3.21 Change an encapsulation type - No Result (warning)
  • 3.22 Check network configurations for vpls application - PASS (tick)
  • 3.23 Check vpls app configurations - PASS (tick)
  • 3.24 Check connectivity - PASS (tick)
  • 3.25 Remove encapsulation - No Result (warning)
  • 3.26 Check network configurations for vpls application - PASS (tick)
  • 3.27 Check vpls app configurations - PASS (tick)
  • 3.28 Check connectivity - PASS (tick)
  • 3.29 Clean all vpls configurations - No Result (warning)
  • 3.30 Check network configurations for vpls application - PASS (tick)
  • 3.31 Check vpls app configurations - PASS (tick)
  • 3.32 Check connectivity - PASS (tick)