Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 856 Next »

HAsanity at 13 Jul 2017 00:35:18

commit 8b1b51e4a509a304e04cc4825b4597c7abad5157 (HEAD, origin/master, origin/HEAD, master)
Author: Aaron Kruglikov [aaron@onlab.us]
AuthorDate: Wed Jul 12 17:26:16 2017 -0700
Commit: Ray Milkey [ray@opennetworking.org]
CommitDate: Thu Jul 13 01:46:39 2017 +0000

Adding a note that Application ID's must be non-negative, this constraint is already written into the default implementation.

Case 1: Setting up test environment - PASS

Setup the test environment including installing ONOS, starting Mininet and ONOScli sessions.

  • 1.1 Create cell file - No Result (warning)
  • 1.2 Applying cell variable to environment - No Result (warning)
  • 1.3 Starting Mininet - PASS (tick)
  • 1.4 Git checkout and pull master - No Result (warning)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing ONOS package - PASS (tick)
  • 1.7 Set up ONOS secure SSH - PASS (tick)
  • 1.8 Checking if ONOS is up yet - PASS (tick)
  • 1.9 Starting ONOS CLI sessions - PASS (tick)
  • 1.10 Checking ONOS nodes - PASS (tick)
  • 1.11 Activate apps defined in the params file - No Result (warning)
  • 1.12 Set ONOS configurations - PASS (tick)
  • 1.13 App Ids check - PASS (tick)

Case 2: Assigning devices to controllers - PASS

Assign switches to ONOS using 'ovs-vsctl' and check that an ONOS node becomes the master of the device.

  • 2.1 Assign switches to controllers - PASS (tick)

Case 8: Compare ONOS Topology view to Mininet topology - PASS

Compare topology objects between Mininet and ONOS

  • 8.1 Comparing ONOS topology to MN topology - PASS (tick)
  • 8.2 Hosts view is consistent across all ONOS nodes - PASS (tick)
  • 8.3 Hosts information is correct - PASS (tick)
  • 8.4 Host attachment points to the network - PASS (tick)
  • 8.5 Clusters view is consistent across all ONOS nodes - PASS (tick)
  • 8.6 There is only one SCC - PASS (tick)
  • 8.7 Device information is correct - PASS (tick)
  • 8.8 Links are correct - PASS (tick)
  • 8.9 Hosts are correct - PASS (tick)
  • 8.10 Checking ONOS nodes - PASS (tick)

Case 21: Assigning Controller roles for switches - PASS

Check that ONOS is connected to each device. Then manually assign mastership to specific ONOS nodes using 'device-role'

  • 21.1 Assign mastership of switches to specific controllers - PASS (tick)
  • 21.2 Check mastership was correctly assigned - PASS (tick)

Case 8: Compare ONOS Topology view to Mininet topology - PASS

Compare topology objects between Mininet and ONOS

  • 8.1 Comparing ONOS topology to MN topology - PASS (tick)
  • 8.2 Hosts view is consistent across all ONOS nodes - PASS (tick)
  • 8.3 Hosts information is correct - PASS (tick)
  • 8.4 Host attachment points to the network - PASS (tick)
  • 8.5 Clusters view is consistent across all ONOS nodes - PASS (tick)
  • 8.6 There is only one SCC - PASS (tick)
  • 8.7 Device information is correct - PASS (tick)
  • 8.8 Links are correct - PASS (tick)
  • 8.9 Hosts are correct - PASS (tick)
  • 8.10 Checking ONOS nodes - PASS (tick)

Case 3: Adding host Intents - PASS

Discover hosts by using pingall then assign predetermined host-to-host intents. After installation, check that the intent is distributed to all nodes and the state is INSTALLED

  • 3.1 Install reactive forwarding app - PASS (tick)
  • 3.2 Check app ids - PASS (tick)
  • 3.3 Discovering Hosts( Via pingall for now ) - PASS (tick)
  • 3.4 Uninstall reactive forwarding app - PASS (tick)
  • 3.5 Check app ids - PASS (tick)
  • 3.6 Add host intents via cli - PASS (tick)
  • 3.7 Intent Anti-Entropy dispersion - PASS (tick)

Case 4: Verify connectivity by sending traffic across Intents - PASS

Ping across added host intents to check functionality and check the state of the intent

  • 4.1 Check Intent state - PASS (tick)
  • 4.2 Ping across added host intents - PASS (tick)
  • 4.3 Check leadership of topics - PASS (tick)
  • 4.4 Wait a minute then ping again - PASS (tick)

Case 5: Setting up and gathering data for current state - PASS

  • 5.1 Check that each switch has a master - PASS (tick)
  • 5.2 Get the Mastership of each switch from each controller - PASS (tick)
  • 5.3 Check for consistency in roles from each controller - PASS (tick)
  • 5.4 Get the intents from each controller - PASS (tick)
  • 5.5 Check for consistency in Intents from each controller - PASS (tick)
  • 5.6 Get the flows from each controller - PASS (tick)
  • 5.7 Check for consistency in Flows from each controller - PASS (tick)
  • 5.8 Get the OF Table entries - No Result (warning)
  • 5.9 Start continuous pings - No Result (warning)
  • 5.10 Collecting topology information from ONOS - No Result (warning)
  • 5.11 Host view is consistent across ONOS nodes - PASS (tick)
  • 5.12 Each host has an IP address - PASS (tick)
  • 5.13 Cluster view is consistent across ONOS nodes - PASS (tick)
  • 5.14 Cluster view correct across ONOS nodes - PASS (tick)
  • 5.15 Comparing ONOS topology to MN - PASS (tick)
  • 5.16 Device information is correct - PASS (tick)
  • 5.17 Links are correct - PASS (tick)
  • 5.18 Hosts are correct - PASS (tick)

Case 14: Start Leadership Election app - PASS

  • 14.1 Install leadership election app - PASS (tick)
  • 14.2 Run for election on each node - PASS (tick)
  • 14.3 First node was elected leader - PASS (tick)

Case 16: Install Primitives app - PASS

  • 16.1 Install Primitives app - PASS (tick)

Case 17: Check for basic functionality with distributed primitives - FAIL

Test the methods of the distributed primitives (counters and sets) throught the cli

  • 17.1 Increment then get a default counter on each node - PASS (tick)
  • 17.2 Get then Increment a default counter on each node - PASS (tick)
  • 17.3 Counters we added have the correct values - PASS (tick)
  • 17.4 Add -8 to then get a default counter on each node - PASS (tick)
  • 17.5 Add 5 to then get a default counter on each node - PASS (tick)
  • 17.6 Get then add 5 to a default counter on each node - PASS (tick)
  • 17.7 Counters we added have the correct values - PASS (tick)
  • 17.8 Distributed Set get - PASS (tick)
  • 17.9 Distributed Set size - PASS (tick)
  • 17.10 Distributed Set add() - FAIL (error)
    • Set add was incorrect
  • 17.11 Distributed Set addAll() - FAIL (error)
    • Set addAll was incorrect
  • 17.12 Distributed Set contains() - FAIL (error)
    • Set contains failed
  • 17.13 Distributed Set containsAll() - PASS (tick)
  • 17.14 Distributed Set remove() - FAIL (error)
    • Set remove was incorrect
  • 17.15 Distributed Set removeAll() - FAIL (error)
    • Set removeAll was incorrect
  • 17.16 Distributed Set addAll() - FAIL (error)
    • Set addAll was incorrect
  • 17.17 Distributed Set clear() - FAIL (error)
    • Set clear was incorrect
  • 17.18 Distributed Set addAll() - FAIL (error)
    • Set addAll was incorrect
  • 17.19 Distributed Set retain() - FAIL (error)
    • Set retain was incorrect
  • 17.20 Partitioned Transactional maps put - PASS (tick)
  • 17.21 Partitioned Transactional maps get - FAIL (error)
    • Partitioned Transactional Map values incorrect
  • 17.22 Get the value of a new value - FAIL (error)
    • Error getting atomic Value None, found: ['null', 'null', 'null', None, 'null', 'null', 'null']
  • 17.23 Atomic Value set() - FAIL (error)
    • Error setting atomic Value[1, 1, 1, -1, 1, 1, 1]
  • 17.24 Get the value after set() - FAIL (error)
    • Error getting atomic Value foo, found: ['foo', 'foo', 'foo', None, 'foo', 'foo', 'foo']
  • 17.25 Atomic Value compareAndSet() - PASS (tick)
  • 17.26 Get the value after compareAndSet() - FAIL (error)
    • Error getting atomic Value bar, found: ['bar', 'bar', 'bar', None, 'bar', 'bar', 'bar']
  • 17.27 Atomic Value getAndSet() - PASS (tick)
  • 17.28 Get the value after getAndSet() - FAIL (error)
    • Error getting atomic Value: expected baz, found: ['baz', 'baz', 'baz', None, 'baz', 'baz', 'baz']
  • 17.29 Atomic Value destory() - PASS (tick)
  • 17.30 Get the value after destroy() - FAIL (error)
    • Error getting atomic Value None, found: ['null', 'null', 'null', None, 'null', 'null', 'null']
  • 17.31 Work Queue add() - PASS (tick)
  • 17.32 Check the work queue stats - No Result (warning)

Case 6: Wait 60 seconds instead of inducing a failure - PASS

Case 8: Compare ONOS Topology view to Mininet topology - PASS

  • 8.1 Comparing ONOS topology to MN topology - FAIL (error)
    • ONOS topology don't match Mininet
  • 8.2 Hosts view is consistent across all ONOS nodes - FAIL (error)
    • ONOS nodes have different views of hosts
  • 8.3 Hosts information is correct - FAIL (error)
    • Host information is incorrect
  • 8.4 Host attachment points to the network - PASS (tick)
  • No labels