Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 13 Current »

SRSanity at 20 Aug 2017 01:24:06

 

commit 247dfd82a5c5316fa4ea8a0147b401fd25a8796f (HEAD, origin/onos-1.9, onos-1.9)
Author: sivachidambaram subramanian [sisubram@partner.ciena.com]
AuthorDate: Wed Apr 12 11:36:12 2017 +0530
Commit: Thomas Vachuska [tom@opennetworking.org]
CommitDate: Mon Aug 14 20:50:16 2017 +0000

[ONOS-6266] 'garbageCollect' is not working for groups after ONOS restart

Case 1: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 1.1 Constructing test variables - No Result (warning)
  • 1.2 Constructing test variables - PASS (tick)
  • 1.3 Apply cell to environment - PASS (tick)
  • 1.4 Creating ONOS package - PASS (tick)
  • 1.5 Installing ONOS package - PASS (tick)
  • 1.6 Set up ONOS secure SSH - PASS (tick)
  • 1.7 Checking ONOS service - PASS (tick)
  • 1.8 Checking if ONOS CLI is ready - PASS (tick)
  • 1.9 Starting Mininet Topology - PASS (tick)
  • 1.10 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 1.11 Check whether all flow status are ADDED - PASS (tick)
  • 1.12 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.13 Connectivity for [u'olt10', u'vsg10'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.14 Connectivity for [u'olt5', u'vsg5'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.15 Stopping Mininet - PASS (tick)
  • 1.16 Copying karaf logs - PASS (tick)

Case 2: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Creating ONOS package - PASS (tick)
  • 2.3 Installing ONOS package - PASS (tick)
  • 2.4 Set up ONOS secure SSH - PASS (tick)
  • 2.5 Checking ONOS service - PASS (tick)
  • 2.6 Checking if ONOS CLI is ready - PASS (tick)
  • 2.7 Starting Mininet Topology - PASS (tick)
  • 2.8 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong: False
  • 2.9 Check whether all flow status are ADDED - PASS (tick)
  • 2.10 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.11 Connectivity for [u'olt10', u'vsg10'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.12 Connectivity for [u'olt5', u'vsg5'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.13 Stopping Mininet - PASS (tick)
  • 2.14 Copying karaf logs - PASS (tick)

Case 3: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Creating ONOS package - PASS (tick)
  • 3.3 Installing ONOS package - PASS (tick)
  • 3.4 Set up ONOS secure SSH - PASS (tick)
  • 3.5 Checking ONOS service - PASS (tick)
  • 3.6 Checking if ONOS CLI is ready - PASS (tick)
  • 3.7 Starting Mininet Topology - PASS (tick)
  • 3.8 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong: False
  • 3.9 Check whether all flow status are ADDED - PASS (tick)
  • 3.10 Connectivity for [u'h1', u'h2'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.11 Connectivity for [u'olt10', u'vsg10'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.12 Connectivity for [u'olt5', u'vsg5'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.13 Stopping Mininet - PASS (tick)
  • 3.14 Copying karaf logs - PASS (tick)

Case 4: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Creating ONOS package - PASS (tick)
  • 4.3 Installing ONOS package - PASS (tick)
  • 4.4 Set up ONOS secure SSH - PASS (tick)
  • 4.5 Checking ONOS service - PASS (tick)
  • 4.6 Checking if ONOS CLI is ready - PASS (tick)
  • 4.7 Starting Mininet Topology - PASS (tick)
  • 4.8 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 4.9 Check whether all flow status are ADDED - PASS (tick)
  • 4.10 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.11 Connectivity for [u'olt10', u'vsg10'] CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.12 Connectivity for [u'olt5', u'vsg5'] CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.13 Stopping Mininet - PASS (tick)
  • 4.14 Copying karaf logs - PASS (tick)

Case 5: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Creating ONOS package - PASS (tick)
  • 5.3 Installing ONOS package - PASS (tick)
  • 5.4 Set up ONOS secure SSH - PASS (tick)
  • 5.5 Checking ONOS service - PASS (tick)
  • 5.6 Checking if ONOS CLI is ready - PASS (tick)
  • 5.7 Starting Mininet Topology - PASS (tick)
  • 5.8 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong: False
  • 5.9 Check whether all flow status are ADDED - PASS (tick)
  • 5.10 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.11 Connectivity for [u'olt10', u'vsg10'] CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.12 Connectivity for [u'olt5', u'vsg5'] CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.13 Stopping Mininet - PASS (tick)
  • 5.14 Copying karaf logs - PASS (tick)

Case 6: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Creating ONOS package - PASS (tick)
  • 6.3 Installing ONOS package - PASS (tick)
  • 6.4 Set up ONOS secure SSH - PASS (tick)
  • 6.5 Checking ONOS service - PASS (tick)
  • 6.6 Checking if ONOS CLI is ready - PASS (tick)
  • 6.7 Starting Mininet Topology - PASS (tick)
  • 6.8 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong: False
  • 6.9 Check whether all flow status are ADDED - PASS (tick)
  • 6.10 Connectivity for [u'h1', u'h2'] CASE4 - FAIL (error)
    • IP connectivity failed
  • 6.11 Connectivity for [u'olt10', u'vsg10'] CASE4 - FAIL (error)
    • IP connectivity failed
  • 6.12 Connectivity for [u'olt5', u'vsg5'] CASE4 - FAIL (error)
    • IP connectivity failed
  • 6.13 Stopping Mininet - PASS (tick)
  • 6.14 Copying karaf logs - PASS (tick)
  • No labels