Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
SRBridging at 30 Jul 2020 19:58:22
commit c6ea647501cbeccb9ce02ce85860743b264636e9 (HEAD -] master, origin/master, origin/HEAD)
Author: Thomas Vachuska [tom@opennetworking.org]
AuthorDate: Thu Jul 30 20:49:37 2020 +0000
Commit: Thomas Vachuska [tom@opennetworking.org]
CommitDate: Thu Jul 30 23:24:24 2020 +0000
Revert "Introduced SetPackage and SwitchControlProcessor RPC to gNOI implementation."
--
This reverts commit 992bf52f25d491afec8d8e54efb5c3a8125b77bb.
Reason for revert: Broke the master build.
Change-Id: If47508a8cff95bd6e9c57f7234baa517879a54cf
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - PASS
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Set logging levels - PASS
- 5.14 Set ONOS configurations - PASS
- 5.15 Starting Mininet Topology - PASS
- 5.16 Check whether the flow count is bigger than 28 - PASS
- 5.17 Check whether all flow status are ADDED - PASS
- 5.18 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - PASS
- 5.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
- 5.20 Stopping Mininet - PASS
- 5.21 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, stratum switches and 3 ONOS instances - PASS
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Check whether the flow count is bigger than 74 - PASS
- 6.15 Check whether all flow status are ADDED - PASS
- 6.16 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS
- 6.17 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - PASS
- 6.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.19 Stopping Mininet - PASS
- 6.20 Copying karaf logs - PASS
Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, stratum switches and 3 ONOS instances - PASS
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Check whether the flow count is bigger than 64 - PASS
- 7.15 Check whether all flow status are ADDED - PASS
- 7.16 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS
- 7.17 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS
- 7.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.20 Stopping Mininet - PASS
- 7.21 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances - FAIL
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Set logging levels - PASS
- 8.12 Set ONOS configurations - PASS
- 8.13 Starting Mininet Topology - PASS
- 8.14 Check whether the flow count is bigger than 212 - PASS
- 8.15 Check whether all flow status are ADDED - PASS
- 8.16 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 8.17 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - FAIL
- Flow count looks wrong: 24
- 8.18 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS
- 8.19 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 8.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - FAIL
- IP connectivity failed
- 8.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS
- 8.22 Stopping Mininet - PASS
- 8.23 Copying karaf logs - PASS