Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 45 Next »

HAbackupRecover at 13 Aug 2020 00:06:20

HAbackupRecover

commit f198430fee8d188a8704f0cc06f403f10df70c3a (HEAD, origin/onos-2.2, onos-2.2)
Author: Andrea Campanella [andrea@opennetworking.org]
AuthorDate: Mon Aug 10 18:06:42 2020 +0200
Commit: Andrea Campanella [andrea@opennetworking.org]
CommitDate: Wed Aug 12 06:47:09 2020 +0000

Ports and port description are not cleared up properly upon removal

Case 1: Starting up 5 node(s) ONOS cluster - PASS

Set up ONOS with 5 node(s) ONOS cluster

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Starting Mininet - PASS (tick)
  • 1.6 Creating ONOS package - PASS (tick)
  • 1.7 Installing Atomix - PASS (tick)
  • 1.8 Installing ONOS package - PASS (tick)
  • 1.9 Set up ONOS secure SSH - PASS (tick)
  • 1.10 Checking ONOS service - PASS (tick)
  • 1.11 Starting ONOS CLI sessions - PASS (tick)
  • 1.12 Checking ONOS nodes - PASS (tick)
  • 1.13 Checking ONOS applications - PASS (tick)
  • 1.14 Checking ONOS nodes - PASS (tick)
  • 1.15 Activate apps defined in the params file - No Result (warning)
  • 1.16 Set ONOS configurations - PASS (tick)
  • 1.17 Check app ids - PASS (tick)
  • 1.18 Set logging levels - PASS (tick)

Case 2: Assigning devices to controllers - PASS

Assign switches to ONOS using 'ovs-vsctl' and check that an ONOS node becomes the master of the device.

  • 2.1 Assign switches to controllers - PASS (tick)

Case 8: Compare ONOS Topology view to Mininet topology - PASS

Compare topology objects between Mininet and ONOS

  • 8.1 Comparing ONOS topology to MN topology - PASS (tick)
  • 8.2 Hosts view is consistent across all ONOS nodes - PASS (tick)
  • 8.3 Hosts information is correct - PASS (tick)
  • 8.4 Host attachment points to the network - PASS (tick)
  • 8.5 Clusters view is consistent across all ONOS nodes - PASS (tick)
  • 8.6 There is only one SCC - PASS (tick)
  • 8.7 Device information is correct - PASS (tick)
  • 8.8 Links are correct - PASS (tick)
  • 8.9 Hosts are correct - PASS (tick)
  • 8.10 Checking ONOS nodes - PASS (tick)

Case 21: Assigning Controller roles for switches - PASS

Check that ONOS is connected to each device. Then manually assign mastership to specific ONOS nodes using 'device-role'

  • 21.1 Assign mastership of switches to specific controllers - PASS (tick)
  • 21.2 Check mastership was correctly assigned - PASS (tick)

Case 3: Adding host Intents - FAIL

  • No labels