SRClusterRestart at 01 Nov 2020 01:24:17

SRClusterRestart

commit 3433e31a961b0ce97cb731ceb67fcc7da0c854b5 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Tue Oct 27 16:08:48 2020 +0100
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Thu Oct 29 10:36:07 2020 +0000

[ONOS-8123] Fix an issue related to the component properties.

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong; found 12, expecting at least 116
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.21 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.25 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.26 Checking if ONOS CLI is ready - PASS (tick)
  • 1.27 Checking if ONOS CLI is ready - PASS (tick)
  • 1.28 Checking if ONOS CLI is ready - PASS (tick)
  • 1.29 Checking ONOS nodes - PASS (tick)
  • 1.30 Check number of topology elements - PASS (tick)
  • 1.31 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong; found 12, expecting at least 116
  • 1.32 Check whether all flow status are ADDED - PASS (tick)
  • 1.33 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.36 Stopping Mininet - PASS (tick)
  • 1.37 Copying karaf logs - PASS (tick)

Case 2: Cluster Restart test with 4x4 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Set logging levels - PASS (tick)
  • 2.13 Set ONOS configurations - PASS (tick)
  • 2.14 Starting Mininet Topology - PASS (tick)
  • 2.15 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong; found 24, expecting at least 350
  • 2.16 Check whether all flow status are ADDED - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.20 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.24 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.25 Checking if ONOS CLI is ready - PASS (tick)
  • 2.26 Checking if ONOS CLI is ready - PASS (tick)
  • 2.27 Checking if ONOS CLI is ready - PASS (tick)
  • 2.28 Checking ONOS nodes - PASS (tick)
  • 2.29 Check number of topology elements - PASS (tick)
  • 2.30 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong; found 24, expecting at least 350
  • 2.31 Check whether all flow status are ADDED - PASS (tick)
  • 2.32 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.33 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.34 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.35 Stopping Mininet - PASS (tick)
  • 2.36 Copying karaf logs - PASS (tick)

Case 3: Cluster Restart test with single switch - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Set logging levels - PASS (tick)
  • 3.13 Set ONOS configurations - PASS (tick)
  • 3.14 Starting Mininet Topology - PASS (tick)
  • 3.15 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong; found 3, expecting at least 15
  • 3.16 Check whether all flow status are ADDED - PASS (tick)
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.21 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.25 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.26 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.27 Checking if ONOS CLI is ready - PASS (tick)
  • 3.28 Checking if ONOS CLI is ready - PASS (tick)
  • 3.29 Checking if ONOS CLI is ready - PASS (tick)
  • 3.30 Checking ONOS nodes - PASS (tick)
  • 3.31 Check number of topology elements - PASS (tick)
  • 3.32 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong; found 3, expecting at least 15
  • 3.33 Check whether all flow status are ADDED - PASS (tick)
  • 3.34 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.37 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.38 Stopping Mininet - PASS (tick)
  • 3.39 Copying karaf logs - PASS (tick)
  • No labels