Jenkins test result for 18:45 on Dec 01, 2014.Test HATestSanity
************************************
Result summary for Testcase1
ONOS HA Sanity test - initialization
Removing raft logs
Uninstalling ONOS
commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Mon Dec 1 17:02:45 2014 -0800
Commit: Brian O'Connor [bocon@onlab.us]
CommitDate: Mon Dec 1 17:16:55 2014 -0800
Adding Leadership Listener to IntentBatchService
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.75712299347 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Error in getting ONOS intents
ONOS nodes have different views of intents
Flow count is consistent across all ONOS nodes
State check NOT successful
Result: Failed
Result summary for Testcase6
Wait 60 seconds instead of inducing a failure
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Error in getting ONOS intents
ONOS nodes have different views of intents
The Intents changed during failure
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73878097534 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.75174403191 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.58711504936 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.6993188858 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.77052402496 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestMinorityRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart minority of ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Mon Dec 1 17:02:45 2014 -0800
Commit: Brian O'Connor [bocon@onlab.us]
CommitDate: Mon Dec 1 17:16:55 2014 -0800
Adding Leadership Listener to IntentBatchService
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.94441199303 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Error in getting ONOS intents
ONOS nodes have different views of intents
Flow count is consistent across all ONOS nodes
State check NOT successful
Result: Failed
Result summary for Testcase6
Killing 3 ONOS nodes
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Error in getting ONOS intents
ONOS nodes have different views of intents
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.79420399666 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73914003372 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.82780599594 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.72420811653 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73126101494 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestClusterRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart all ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Mon Dec 1 17:02:45 2014 -0800
Commit: Brian O'Connor [bocon@onlab.us]
CommitDate: Mon Dec 1 17:16:55 2014 -0800
Adding Leadership Listener to IntentBatchService
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.74449014664 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Error in getting ONOS intents
ONOS nodes have different views of intents
Flow count is consistent across all ONOS nodes
State check NOT successful
Result: Failed
Result summary for Testcase6
Restart entire ONOS cluster
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Error in getting ONOS intents
ONOS nodes have different views of intents
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']
Switches in ONOS but not in MN:
[]
ONOS1 Switches view is incorrect
The list of ports for switch s3(0000000000003000) does not match:
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS1 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 39 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS1 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']
Switches in ONOS but not in MN:
[]
ONOS2 Switches view is incorrect
The list of ports for switch s3(0000000000003000) does not match:
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS2 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 40 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS2 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']
Switches in ONOS but not in MN:
[]
ONOS3 Switches view is incorrect
The list of ports for switch s3(0000000000003000) does not match:
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS3 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 40 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS3 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']
Switches in ONOS but not in MN:
[]
ONOS4 Switches view is incorrect
The list of ports for switch s3(0000000000003000) does not match:
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS4 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS4 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS5 Switches view is incorrect
The list of ports for switch s3(0000000000003000) does not match:
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS5 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS5 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS6 Switches view is incorrect
The list of ports for switch s3(0000000000003000) does not match:
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS6 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS6 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS7 Switches view is incorrect
The list of ports for switch s3(0000000000003000) does not match:
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS7 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS7 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS1 Switches view is incorrect
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS1 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 43 unidirectional links
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS1 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS2 Switches view is incorrect
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS2 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 43 unidirectional links
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS2 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS3 Switches view is incorrect
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS3 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS3 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS4 Switches view is incorrect
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS4 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS4 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS5 Switches view is incorrect
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS5 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS5 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS6 Switches view is incorrect
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS6 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS6 links view is incorrect
Switches in MN but not in ONOS:
['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']
Switches in ONOS but not in MN:
[]
ONOS7 Switches view is incorrect
The list of ports for switch s19(0000000000006019) does not match:
The list of ports for switch s18(0000000000006018) does not match:
The list of ports for switch s1(0000000000001000) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s21(0000000000006021) does not match:
The list of ports for switch s24(0000000000006024) does not match:
The list of ports for switch s28(0000000000002800) does not match:
ONOS7 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 41 unidirectional links
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS7 links view is incorrect
Switches in MN but not in ONOS:
['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023']
Switches in ONOS but not in MN:
[]
ONOS1 Switches view is incorrect
Switches in MN but not in ONOS:
['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021']
Switches in ONOS but not in MN:
[]
ONOS2 Switches view is incorrect
Switches in MN but not in ONOS:
['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021']
Switches in ONOS but not in MN:
[]
ONOS3 Switches view is incorrect
Switches in MN but not in ONOS:
['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021']
Switches in ONOS but not in MN:
[]
ONOS4 Switches view is incorrect
Switches in MN but not in ONOS:
['0000000000002800', '0000000000006019']
Switches in ONOS but not in MN:
[]
ONOS5 Switches view is incorrect
Switches in MN but not in ONOS:
['0000000000006019']
Switches in ONOS but not in MN:
[]
ONOS6 Switches view is incorrect
Switches in MN but not in ONOS:
['0000000000006019']
Switches in ONOS but not in MN:
[]
ONOS7 Switches view is incorrect
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 61.5588748455 seconds, 9 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.65032815933 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.66511106491 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.8058989048 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.65204310417 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test SingleInstanceHATestRestart
************************************
Result summary for Testcase1
ONOS Single node cluster restart HA test - initialization
Removing raft logs
Uninstalling ONOS
commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Mon Dec 1 17:02:45 2014 -0800
Commit: Brian O'Connor [bocon@onlab.us]
CommitDate: Mon Dec 1 17:16:55 2014 -0800
Adding Leadership Listener to IntentBatchService
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.959264993668 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase5
Setting up and gathering data for current state
Error in getting ONOS intents
State check NOT successful
Result: Failed
Result summary for Testcase6
Restart ONOS node
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Error in getting ONOS intents
ONOS nodes have different views of intents
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Mininet has 29 bidirectional links and ONOS has 15 unidirectional links
ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2
ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2
ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3
ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2
ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4
ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5
ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6
ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7
ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2
ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8
ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2
ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9
ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2
ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10
ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2
ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11
ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2
ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12
ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2
ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4
ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS1 links view is incorrect
Switches in MN but not in ONOS:
['0000000000006026']
Switches in ONOS but not in MN:
[]
ONOS1 Switches view is incorrect
The list of ports for switch s26(0000000000006026) does not match:
ONOS1 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 16 unidirectional links
ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2
ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3
ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4
ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2
ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5
ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2
ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6
ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2
ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7
ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8
ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9
ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10
ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2
ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11
ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12
ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2
ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2
ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4
ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS1 links view is incorrect
Switches in MN but not in ONOS:
['0000000000006007', '0000000000006020', '0000000000006023', '0000000000006026', '0000000000006027']
Switches in ONOS but not in MN:
[]
ONOS1 Switches view is incorrect
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s27(0000000000006027) does not match:
The list of ports for switch s23(0000000000006023) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s26(0000000000006026) does not match:
ONOS1 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 5 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2
ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2
ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2
ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2
ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3
ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2
ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4
ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5
ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2
ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6
ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7
ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2
ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2
ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10
ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2
ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11
ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2
ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12
ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2
ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4
ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2
ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4
ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS1 links view is incorrect
Switches in MN but not in ONOS:
['0000000000003004', '0000000000005000', '0000000000006007', '0000000000006020', '0000000000006026', '0000000000006027']
Switches in ONOS but not in MN:
[]
ONOS1 Switches view is incorrect
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s5(0000000000005000) does not match:
The list of ports for switch s4(0000000000003004) does not match:
The list of ports for switch s20(0000000000006020) does not match:
The list of ports for switch s26(0000000000006026) does not match:
The list of ports for switch s27(0000000000006027) does not match:
ONOS1 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 5 unidirectional links
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2
ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2
ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2
ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2
ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3
ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4
ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2
ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5
ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2
ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6
ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2
ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7
ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2
ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10
ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11
ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2
ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12
ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2
ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2
ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4
ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2
ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4
ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS1 links view is incorrect
Switches in MN but not in ONOS:
['0000000000003004', '0000000000006007', '0000000000006027']
Switches in ONOS but not in MN:
[]
ONOS1 Switches view is incorrect
The list of ports for switch s7(0000000000006007) does not match:
The list of ports for switch s4(0000000000003004) does not match:
The list of ports for switch s27(0000000000006027) does not match:
ONOS1 ports view is incorrect
Mininet has 29 bidirectional links and ONOS has 10 unidirectional links
ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2
ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5
ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2
ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6
ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2
ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7
ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2
ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8
ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2
ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9
ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2
ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10
ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2
ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11
ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2
ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12
ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3
ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3
ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2
ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3
ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2
ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3
ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2
ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7
ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2
ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5
ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2
ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4
ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2
ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4
ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6
ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9
ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2
ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8
ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2
ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2
ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11
ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12
ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2
ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4
ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2
ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3
ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2
ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4
ONOS1 links view is incorrect
Mininet has 29 bidirectional links and ONOS has 53 unidirectional links
ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2
ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2
ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3
ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4
ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3
ONOS1 links view is incorrect
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 64.1026730537 seconds, 6 tries
Giving up on topology convergence
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.03037691116 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.951661109924 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.959676027298 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.938219070435 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass