Jenkins test result for 18:45 on Dec 01, 2014.

Test Plan for HA Test Cases

  • HATestSanity - Results: 13 Passed, 10 Failed
  • HATestMinorityRestart - Results: 13 Passed, 10 Failed
  • HATestClusterRestart - Results: 19 Passed, 4 Failed
  • SingleInstanceHATestRestart - Results: 12 Passed, 11 Failed
  • Test HATestSanity

    ************************************

    Result summary for Testcase1

    ONOS HA Sanity test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Mon Dec 1 17:02:45 2014 -0800

    Commit: Brian O'Connor [bocon@onlab.us]

    CommitDate: Mon Dec 1 17:16:55 2014 -0800

    Adding Leadership Listener to IntentBatchService

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.75712299347 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Error in getting ONOS intents

    ONOS nodes have different views of intents

    Flow count is consistent across all ONOS nodes

    State check NOT successful

    Result: Failed

    Result summary for Testcase6

    Wait 60 seconds instead of inducing a failure

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Error in getting ONOS intents

    ONOS nodes have different views of intents

    The Intents changed during failure

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73878097534 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.75174403191 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.58711504936 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.6993188858 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.77052402496 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestMinorityRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart minority of ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Mon Dec 1 17:02:45 2014 -0800

    Commit: Brian O'Connor [bocon@onlab.us]

    CommitDate: Mon Dec 1 17:16:55 2014 -0800

    Adding Leadership Listener to IntentBatchService

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.94441199303 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Error in getting ONOS intents

    ONOS nodes have different views of intents

    Flow count is consistent across all ONOS nodes

    State check NOT successful

    Result: Failed

    Result summary for Testcase6

    Killing 3 ONOS nodes

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Error in getting ONOS intents

    ONOS nodes have different views of intents

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.79420399666 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73914003372 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.82780599594 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.72420811653 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73126101494 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestClusterRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart all ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Mon Dec 1 17:02:45 2014 -0800

    Commit: Brian O'Connor [bocon@onlab.us]

    CommitDate: Mon Dec 1 17:16:55 2014 -0800

    Adding Leadership Listener to IntentBatchService

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.74449014664 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Error in getting ONOS intents

    ONOS nodes have different views of intents

    Flow count is consistent across all ONOS nodes

    State check NOT successful

    Result: Failed

    Result summary for Testcase6

    Restart entire ONOS cluster

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Error in getting ONOS intents

    ONOS nodes have different views of intents

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 39 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']

    Switches in ONOS but not in MN:

    []

    ONOS2 Switches view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 40 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS2 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']

    Switches in ONOS but not in MN:

    []

    ONOS3 Switches view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 40 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS3 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024', '0000000000006027']

    Switches in ONOS but not in MN:

    []

    ONOS4 Switches view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS4 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS5 Switches view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS5 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000003004', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS6 Switches view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS6 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002000', '0000000000002800', '0000000000003000', '0000000000006007', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006022', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS7 Switches view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS7 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 43 unidirectional links

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS2 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 43 unidirectional links

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS2 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006020', '0000000000006021', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS3 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS3 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS4 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS4 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS5 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS5 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS6 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS6 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000001000', '0000000000002800', '0000000000003000', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023', '0000000000006024']

    Switches in ONOS but not in MN:

    []

    ONOS7 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 41 unidirectional links

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS7 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021', '0000000000006023']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021']

    Switches in ONOS but not in MN:

    []

    ONOS2 Switches view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021']

    Switches in ONOS but not in MN:

    []

    ONOS3 Switches view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000002800', '0000000000006018', '0000000000006019', '0000000000006021']

    Switches in ONOS but not in MN:

    []

    ONOS4 Switches view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000002800', '0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS5 Switches view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS6 Switches view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS7 Switches view is incorrect

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 61.5588748455 seconds, 9 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.65032815933 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.66511106491 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.8058989048 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.65204310417 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test SingleInstanceHATestRestart

    ************************************

    Result summary for Testcase1

    ONOS Single node cluster restart HA test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 86f6f7f01193e69c297d6cba14434dbc74d81c8d (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Mon Dec 1 17:02:45 2014 -0800

    Commit: Brian O'Connor [bocon@onlab.us]

    CommitDate: Mon Dec 1 17:16:55 2014 -0800

    Adding Leadership Listener to IntentBatchService

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.959264993668 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase5

    Setting up and gathering data for current state

    Error in getting ONOS intents

    State check NOT successful

    Result: Failed

    Result summary for Testcase6

    Restart ONOS node

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Error in getting ONOS intents

    ONOS nodes have different views of intents

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Mininet has 29 bidirectional links and ONOS has 15 unidirectional links

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006026']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s26(0000000000006026) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 16 unidirectional links

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006007', '0000000000006020', '0000000000006023', '0000000000006026', '0000000000006027']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s27(0000000000006027) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000005000', '0000000000006007', '0000000000006020', '0000000000006026', '0000000000006027']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s27(0000000000006027) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007', '0000000000006027']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s27(0000000000006027) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 10 unidirectional links

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006021/2 -> 0000000000006007/6

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS1 links view is incorrect

    Mininet has 29 bidirectional links and ONOS has 53 unidirectional links

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS1 links view is incorrect

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 64.1026730537 seconds, 6 tries

    Giving up on topology convergence

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.03037691116 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.951661109924 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.959676027298 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.938219070435 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass