Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 39 Next »

**************************************

Jenkins test result for 23:27 on Dec 01, 2014.

Test Plan for HA Test Cases

  • HATestSanity - Results: 23 Passed, 0 Failed
  • HATestMinorityRestart - Results: 18 Passed, 5 Failed
  • HATestClusterRestart - Results: 22 Passed, 1 Failed
  • SingleInstanceHATestRestart - Results: 23 Passed, 0 Failed
  • Test HATestSanity

    ************************************

    Result summary for Testcase1

    ONOS HA Sanity test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 8d21c790ee50878819caa13ca7f02df2420088f4 (HEAD, origin/master, origin/HEAD, master)

    Author: Madan Jampani [madan@onlab.us]

    AuthorDate: Mon Dec 1 16:31:07 2014 -0800

    Commit: Pavlin Radoslavov [pavlin@onlab.us]

    CommitDate: Tue Dec 2 04:55:15 2014 +0000

    LeadershipService API change: Using NodeId in place of ControllerNode.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.1754989624 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Wait 60 seconds instead of inducing a failure

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    Intents are consistent with before failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.70828008652 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.81139802933 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.92753887177 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.79923391342 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.79787898064 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestMinorityRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart minority of ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 8d21c790ee50878819caa13ca7f02df2420088f4 (HEAD, origin/master, origin/HEAD, master)

    Author: Madan Jampani [madan@onlab.us]

    AuthorDate: Mon Dec 1 16:31:07 2014 -0800

    Commit: Pavlin Radoslavov [pavlin@onlab.us]

    CommitDate: Tue Dec 2 04:55:15 2014 +0000

    LeadershipService API change: Using NodeId in place of ControllerNode.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.34068202972 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Killing 3 ONOS nodes

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.09202218056 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.86577391624 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.74817204475 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.80963993073 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.83258199692 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestClusterRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart all ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 8d21c790ee50878819caa13ca7f02df2420088f4 (HEAD, origin/master, origin/HEAD, master)

    Author: Madan Jampani [madan@onlab.us]

    AuthorDate: Mon Dec 1 16:31:07 2014 -0800

    Commit: Pavlin Radoslavov [pavlin@onlab.us]

    CommitDate: Tue Dec 2 04:55:15 2014 +0000

    LeadershipService API change: Using NodeId in place of ControllerNode.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.22663497925 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Restart entire ONOS cluster

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.89758300781 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.84576702118 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73991417885 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.92435193062 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.66662883759 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test SingleInstanceHATestRestart

    ************************************

    Result summary for Testcase1

    ONOS Single node cluster restart HA test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 8d21c790ee50878819caa13ca7f02df2420088f4 (HEAD, origin/master, origin/HEAD, master)

    Author: Madan Jampani [madan@onlab.us]

    AuthorDate: Mon Dec 1 16:31:07 2014 -0800

    Commit: Pavlin Radoslavov [pavlin@onlab.us]

    CommitDate: Tue Dec 2 04:55:15 2014 +0000

    LeadershipService API change: Using NodeId in place of ControllerNode.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.0554869175 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Result: Pass

    Result summary for Testcase6

    Restart ONOS node

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.934237003326 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.935700893402 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.935101985931 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.928394079208 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.941167831421 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    • No labels