Jenkins test result for 06:09 on Dec 02, 2014.Test HATestSanity
************************************
Result summary for Testcase1
ONOS HA Sanity test - initialization
Removing raft logs
Uninstalling ONOS
commit b2e74a0f108861ebca56d83c051ed491b699ada1 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Sun Nov 30 13:54:38 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Tue Dec 2 09:49:25 2014 +0000
Lazily compute SCC, etc. on demand
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.28388500214 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Wait 60 seconds instead of inducing a failure
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
Intents are consistent with before failure
No changes were found in the flow tables
No loss of dataplane connectivity
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.93398499489 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.82786989212 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.76873517036 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.74951910973 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.88004899025 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestMinorityRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart minority of ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit b2e74a0f108861ebca56d83c051ed491b699ada1 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Sun Nov 30 13:54:38 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Tue Dec 2 09:49:25 2014 +0000
Lazily compute SCC, etc. on demand
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.1264359951 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Killing 3 ONOS nodes
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.98613286018 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.80006980896 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.9099149704 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.85304498672 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.96336698532 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestClusterRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart all ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit b2e74a0f108861ebca56d83c051ed491b699ada1 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Sun Nov 30 13:54:38 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Tue Dec 2 09:49:25 2014 +0000
Lazily compute SCC, etc. on demand
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.33019804955 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Restart entire ONOS cluster
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 7.08688998222 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.76133799553 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.88748216629 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.73572206497 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 7 seconds to read the topology from ONOS): 6.56644296646 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test SingleInstanceHATestRestart
************************************
Result summary for Testcase1
ONOS Single node cluster restart HA test - initialization
Removing raft logs
Uninstalling ONOS
commit b2e74a0f108861ebca56d83c051ed491b699ada1 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Sun Nov 30 13:54:38 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Tue Dec 2 09:49:25 2014 +0000
Lazily compute SCC, etc. on demand
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.03971195221 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Result: Pass
Result summary for Testcase6
Restart ONOS node
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.947243928909 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.922338008881 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.930269956589 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.898078203201 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.917213916779 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass