Jenkins test result for 17:41 on Dec 03, 2014.Test HATestSanity
************************************
Result summary for Testcase1
ONOS HA Sanity test - initialization
Removing raft logs
Uninstalling ONOS
commit 351e2f63ef479c26e58fbca5f72546dd97dc8c56 (HEAD, origin/master, origin/HEAD, master)
Author: Sho SHIMIZU [sshimizu@us.fujitsu.com]
AuthorDate: Wed Dec 3 14:20:06 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 00:57:26 2014 +0000
Add ToDo comment
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7704119682 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Wait 60 seconds instead of inducing a failure
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
Intents are consistent with before failure
No changes were found in the flow tables
No loss of dataplane connectivity
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6920380592 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5365519524 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6785080433 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5863120556 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7730169296 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestMinorityRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart minority of ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 351e2f63ef479c26e58fbca5f72546dd97dc8c56 (HEAD, origin/master, origin/HEAD, master)
Author: Sho SHIMIZU [sshimizu@us.fujitsu.com]
AuthorDate: Wed Dec 3 14:20:06 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 00:57:26 2014 +0000
Add ToDo comment
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.926625967 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Killing 3 ONOS nodes
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.8607649803 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5186140537 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5552611351 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.4218640327 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5791399479 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestClusterRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart all ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 351e2f63ef479c26e58fbca5f72546dd97dc8c56 (HEAD, origin/master, origin/HEAD, master)
Author: Sho SHIMIZU [sshimizu@us.fujitsu.com]
AuthorDate: Wed Dec 3 14:20:06 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 00:57:26 2014 +0000
Add ToDo comment
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.1194951534 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Restart entire ONOS cluster
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.2976000309 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.481867075 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.3286459446 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 63.7424349785 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.3337318897 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test SingleInstanceHATestRestart
************************************
Result summary for Testcase1
ONOS Single node cluster restart HA test - initialization
Removing raft logs
Uninstalling ONOS
commit 351e2f63ef479c26e58fbca5f72546dd97dc8c56 (HEAD, origin/master, origin/HEAD, master)
Author: Sho SHIMIZU [sshimizu@us.fujitsu.com]
AuthorDate: Wed Dec 3 14:20:06 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 00:57:26 2014 +0000
Add ToDo comment
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.01564598083 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Result: Pass
Result summary for Testcase6
Restart ONOS node
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.959679841995 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.902799844742 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.927342891693 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.93318104744 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.927137851715 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass