Jenkins test result for 23:42 on Dec 03, 2014.Test HATestSanity
************************************
Result summary for Testcase1
ONOS HA Sanity test - initialization
Removing raft logs
Uninstalling ONOS
commit 0ad84ec76d0152c08d1a40352e334abe2c5e3d8e (HEAD, origin/master, origin/HEAD, master)
Author: alshabib [alshabibi.ali@gmail.com]
AuthorDate: Wed Dec 3 22:48:01 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 06:58:29 2014 +0000
setting periodic calls to reasonable intervals
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.9497690201 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Wait 60 seconds instead of inducing a failure
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
Intents are consistent with before failure
No changes were found in the flow tables
No loss of dataplane connectivity
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7168049812 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5463490486 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6344950199 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6773281097 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6022200584 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestMinorityRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart minority of ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 0ad84ec76d0152c08d1a40352e334abe2c5e3d8e (HEAD, origin/master, origin/HEAD, master)
Author: alshabib [alshabibi.ali@gmail.com]
AuthorDate: Wed Dec 3 22:48:01 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 06:58:29 2014 +0000
setting periodic calls to reasonable intervals
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.860311985 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Killing 3 ONOS nodes
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7526500225 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6413149834 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.4892890453 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6920700073 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5783560276 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestClusterRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart all ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 0ad84ec76d0152c08d1a40352e334abe2c5e3d8e (HEAD, origin/master, origin/HEAD, master)
Author: alshabib [alshabibi.ali@gmail.com]
AuthorDate: Wed Dec 3 22:48:01 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 06:58:29 2014 +0000
setting periodic calls to reasonable intervals
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.9308488369 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Restart entire ONOS cluster
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.824390173 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 65.1134359837 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.6174900532 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.6235849857 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 63.9758648872 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test SingleInstanceHATestRestart
************************************
Result summary for Testcase1
ONOS Single node cluster restart HA test - initialization
Removing raft logs
Uninstalling ONOS
commit 0ad84ec76d0152c08d1a40352e334abe2c5e3d8e (HEAD, origin/master, origin/HEAD, master)
Author: alshabib [alshabibi.ali@gmail.com]
AuthorDate: Wed Dec 3 22:48:01 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 06:58:29 2014 +0000
setting periodic calls to reasonable intervals
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.01480102539 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Result: Pass
Result summary for Testcase6
Restart ONOS node
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.983502149582 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.942887067795 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.933655977249 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.899029970169 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.927198171616 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass