**************************************
Jenkins test result for 01:05 on Dec 04, 2014.Test HATestSanity
************************************
Result summary for Testcase1
ONOS HA Sanity test - initialization
Removing raft logs
Uninstalling ONOS
commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Thu Dec 4 00:10:36 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 08:22:09 2014 +0000
tokenizing features.xml
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.721955061 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Wait 60 seconds instead of inducing a failure
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
Intents are consistent with before failure
No changes were found in the flow tables
No loss of dataplane connectivity
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5949239731 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6411590576 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6086530685 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6582510471 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5059599876 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestMinorityRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart minority of ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Thu Dec 4 00:10:36 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 08:22:09 2014 +0000
tokenizing features.xml
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.0776500702 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Killing 3 ONOS nodes
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
No loss of dataplane connectivity
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.824213028 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5722689629 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.8169460297 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6034600735 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.3972380161 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestClusterRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart all ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Thu Dec 4 00:10:36 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 08:22:09 2014 +0000
tokenizing features.xml
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.0313489437 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Restart entire ONOS cluster
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.6965811253 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 65.0904319286 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 65.0214569569 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.1237049103 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS2 is inconsistent with ONOS1
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.4085280895 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test SingleInstanceHATestRestart
************************************
Result summary for Testcase1
ONOS Single node cluster restart HA test - initialization
Removing raft logs
Uninstalling ONOS
commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Thu Dec 4 00:10:36 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Thu Dec 4 08:22:09 2014 +0000
tokenizing features.xml
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.10043597221 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Result: Pass
Result summary for Testcase6
Restart ONOS node
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant State Tests Passed
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.907227039337 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.898841142654 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.924551010132 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.919090986252 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.924685001373 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass