Jenkins test result for 01:05 on Dec 04, 2014.

Test Plan for HA Test Cases

  • HATestSanity - Results: 23 Passed, 0 Failed
  • HATestMinorityRestart - Results: 18 Passed, 5 Failed
  • HATestClusterRestart - Results: 17 Passed, 6 Failed
  • SingleInstanceHATestRestart - Results: 23 Passed, 0 Failed
  • Test HATestSanity

    ************************************

    Result summary for Testcase1

    ONOS HA Sanity test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Thu Dec 4 00:10:36 2014 -0800

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Dec 4 08:22:09 2014 +0000

    tokenizing features.xml

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.721955061 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Wait 60 seconds instead of inducing a failure

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    Intents are consistent with before failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5949239731 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6411590576 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6086530685 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6582510471 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5059599876 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestMinorityRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart minority of ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Thu Dec 4 00:10:36 2014 -0800

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Dec 4 08:22:09 2014 +0000

    tokenizing features.xml

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.0776500702 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Killing 3 ONOS nodes

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.824213028 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5722689629 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.8169460297 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6034600735 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.3972380161 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestClusterRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart all ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Thu Dec 4 00:10:36 2014 -0800

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Dec 4 08:22:09 2014 +0000

    tokenizing features.xml

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.0313489437 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Restart entire ONOS cluster

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.6965811253 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 65.0904319286 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 65.0214569569 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.1237049103 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.4085280895 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test SingleInstanceHATestRestart

    ************************************

    Result summary for Testcase1

    ONOS Single node cluster restart HA test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 992741f6b2ff9d1aad4c5419b9656b2d2f8a6228 (HEAD, origin/master, origin/HEAD, master)

    Author: Brian O'Connor [bocon@onlab.us]

    AuthorDate: Thu Dec 4 00:10:36 2014 -0800

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Dec 4 08:22:09 2014 +0000

    tokenizing features.xml

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.10043597221 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Result: Pass

    Result summary for Testcase6

    Restart ONOS node

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.907227039337 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.898841142654 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.924551010132 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.919090986252 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.924685001373 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass