Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 97 Next »

 

StartResults

**************************************

Jenkins test result for 15:29 on Dec 08, 2014.

Test Plan for HA Test Cases

  • HATestSanity - Results: 24 Passed, 0 Failed
  • HATestMinorityRestart - Results: 16 Passed, 7 Failed
  • HATestClusterRestart - Results: 23 Passed, 1 Failed
  • SingleInstanceHATestRestart - Results: 24 Passed, 0 Failed
  • Test HATestSanity

    ************************************

    Result summary for Testcase1

    ONOS HA Sanity test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit dec50095c6903f400c51b7b79bdbc681eafd601a (HEAD, origin/master, origin/HEAD, master)

    Author: Thomas Vachuska [tom@onlab.us]

    AuthorDate: Mon Dec 8 11:14:07 2014 -0800

    Commit: Ray Milkey [ray@onlab.us]

    CommitDate: Mon Dec 8 22:54:05 2014 +0000

    Fixed test cell definition files.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.9114480019 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase14

    Result: Pass

    Result summary for Testcase6

    Wait 60 seconds instead of inducing a failure

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6621460915 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    Intents are consistent with before failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5833990574 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.585960865 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6256248951 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6390621662 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestMinorityRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart minority of ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit aab51a3c2b032574973187f09069e4b2f93cfc5b (HEAD, origin/master, origin/HEAD, master)

    Author: Pavlin Radoslavov [pavlin@onlab.us]

    AuthorDate: Mon Dec 8 11:07:38 2014 -0800

    Commit: Pavlin Radoslavov [pavlin@onlab.us]

    CommitDate: Mon Dec 8 11:07:38 2014 -0800

    Added missing CLI output of HostToHostIntent-specific info

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.0619080067 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Killing 3 ONOS nodes

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 66.5153679848 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    Intents are consistent with before failure

    Changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.4646630287 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5074028969 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.3634331226 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5005068779 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestClusterRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart all ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit aab51a3c2b032574973187f09069e4b2f93cfc5b (HEAD, origin/master, origin/HEAD, master)

    Author: Pavlin Radoslavov [pavlin@onlab.us]

    AuthorDate: Mon Dec 8 11:07:38 2014 -0800

    Commit: Pavlin Radoslavov [pavlin@onlab.us]

    CommitDate: Mon Dec 8 11:07:38 2014 -0800

    Added missing CLI output of HostToHostIntent-specific info

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.2544438839 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Restart entire ONOS cluster

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.4692571163 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.8051791191 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6746020317 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5302841663 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.4736778736 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test SingleInstanceHATestRestart

    ************************************

    Result summary for Testcase1

    ONOS Single node cluster restart HA test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit aab51a3c2b032574973187f09069e4b2f93cfc5b (HEAD, origin/master, origin/HEAD, master)

    Author: Pavlin Radoslavov [pavlin@onlab.us]

    AuthorDate: Mon Dec 8 11:07:38 2014 -0800

    Commit: Pavlin Radoslavov [pavlin@onlab.us]

    CommitDate: Mon Dec 8 11:07:38 2014 -0800

    Added missing CLI output of HostToHostIntent-specific info

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.07430005074 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Result: Pass

    Result summary for Testcase6

    Restart ONOS node

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.07266783714 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.919935941696 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.995496988297 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.917414188385 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.899471998215 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    EndResults