Test Plan for HA Test Cases

  • HATestSanity - Results: 24 Passed, 0 Failed
  • HATestMinorityRestart - Results: 19 Passed, 4 Failed
  • HATestClusterRestart - Results: 23 Passed, 1 Failed
  • SingleInstanceHATestRestart - Results: 23 Passed, 1 Failed
  • Test HATestSanity

    ************************************

    Result summary for Testcase1

    ONOS HA Sanity test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit dec50095c6903f400c51b7b79bdbc681eafd601a (HEAD, origin/master, origin/HEAD, master)

    Author: Thomas Vachuska [tom@onlab.us]

    AuthorDate: Mon Dec 8 11:14:07 2014 -0800

    Commit: Ray Milkey [ray@onlab.us]

    CommitDate: Mon Dec 8 22:54:05 2014 +0000

    Fixed test cell definition files.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7786989212 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase14

    Result: Pass

    Result summary for Testcase6

    Wait 60 seconds instead of inducing a failure

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5680711269 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    Intents are consistent with before failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7090449333 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6464030743 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6778059006 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6213748455 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestMinorityRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart minority of ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit dec50095c6903f400c51b7b79bdbc681eafd601a (HEAD, origin/master, origin/HEAD, master)

    Author: Thomas Vachuska [tom@onlab.us]

    AuthorDate: Mon Dec 8 11:14:07 2014 -0800

    Commit: Ray Milkey [ray@onlab.us]

    CommitDate: Mon Dec 8 22:54:05 2014 +0000

    Fixed test cell definition files.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7782008648 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Killing 3 ONOS nodes

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.9498839378 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    The Intents changed during failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6788380146 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5452549458 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6525621414 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5472681522 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestClusterRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart all ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit dec50095c6903f400c51b7b79bdbc681eafd601a (HEAD, origin/master, origin/HEAD, master)

    Author: Thomas Vachuska [tom@onlab.us]

    AuthorDate: Mon Dec 8 11:14:07 2014 -0800

    Commit: Ray Milkey [ray@onlab.us]

    CommitDate: Mon Dec 8 22:54:05 2014 +0000

    Fixed test cell definition files.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7537069321 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase6

    Restart entire ONOS cluster

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 39.5042359829 seconds, 2 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6165540218 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.641906023 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5483269691 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.670732975 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test SingleInstanceHATestRestart

    ************************************

    Result summary for Testcase1

    ONOS Single node cluster restart HA test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit dec50095c6903f400c51b7b79bdbc681eafd601a (HEAD, origin/master, origin/HEAD, master)

    Author: Thomas Vachuska [tom@onlab.us]

    AuthorDate: Mon Dec 8 11:14:07 2014 -0800

    Commit: Ray Milkey [ray@onlab.us]

    CommitDate: Mon Dec 8 22:54:05 2014 +0000

    Fixed test cell definition files.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.02455210686 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Result: Pass

    Result summary for Testcase6

    Restart ONOS node

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.0128891468 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    Changes were found in the flow tables

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.930243968964 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.99614906311 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.914103984833 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.907810926437 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass