**************************************
Jenkins test result for 11:36 on Dec 15, 2014.Test HATestSanity
************************************
Result summary for Testcase1
ONOS HA Sanity test - initialization
Removing raft logs
Uninstalling ONOS
commit ddb7772971b33af75bd1d37ab5e9be4c311e5861 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Thu Dec 11 19:39:04 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Mon Dec 15 18:13:01 2014 +0000
LinkManager: log only if link actually disappeared
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.1072189808 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase14
Result: Pass
Result summary for Testcase6
Wait 60 seconds instead of inducing a failure
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5562410355 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
Intents are consistent with before failure
No changes were found in the flow tables
No loss of dataplane connectivity
Constant State Tests Passed
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5857820511 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.437541008 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.387349844 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.4913370609 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestMinorityRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart minority of ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit ddb7772971b33af75bd1d37ab5e9be4c311e5861 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Thu Dec 11 19:39:04 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Mon Dec 15 18:13:01 2014 +0000
LinkManager: log only if link actually disappeared
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.9004528522 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Killing 3 ONOS nodes
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.5495500565 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
The Intents changed during failure
Changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.3826670647 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
hosts from ONOS3 is inconsistent with ONOS1
hosts from ONOS4 is inconsistent with ONOS1
hosts from ONOS5 is inconsistent with ONOS1
hosts from ONOS6 is inconsistent with ONOS1
hosts from ONOS7 is inconsistent with ONOS1
ONOS nodes have different views of hosts
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.7933430672 seconds, 3 tries
Topology Check Test NOT successful
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.4090070724 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6870279312 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have not been installed correctly, pings failed.
Intents have not been installed correctly, pings failed.
Result: Failed
Result summary for Testcase13
Test Cleanup
Result: Pass
Test HATestClusterRestart
************************************
Result summary for Testcase1
ONOS HA test: Restart all ONOS nodes - initialization
Removing raft logs
Uninstalling ONOS
commit ddb7772971b33af75bd1d37ab5e9be4c311e5861 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Thu Dec 11 19:39:04 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Mon Dec 15 18:13:01 2014 +0000
LinkManager: log only if link actually disappeared
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.9955720901 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Switch roles are consistent across all ONOS nodes
Intents are consistent across all ONOS nodes
Flow count is consistent across all ONOS nodes
Result: Pass
Result summary for Testcase6
Restart entire ONOS cluster
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.9399929047 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of some switches changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Loss of dataplane connectivity detected
Constant state tests failed
Result: Failed
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6953110695 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5375740528 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.611538887 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7664191723 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass
Test SingleInstanceHATestRestart
************************************
Result summary for Testcase1
ONOS Single node cluster restart HA test - initialization
Removing raft logs
Uninstalling ONOS
commit ddb7772971b33af75bd1d37ab5e9be4c311e5861 (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Thu Dec 11 19:39:04 2014 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Mon Dec 15 18:13:01 2014 +0000
LinkManager: log only if link actually disappeared
Result: Pass
Result summary for Testcase2
Assigning switches to controllers
Switch mastership assigned correctly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.07733201981 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase5
Setting up and gathering data for current state
Result: Pass
Result summary for Testcase6
Restart ONOS node
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 1.02249407768 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase3
Adding host intents
Result: Pass
Result summary for Testcase7
Switch roles are consistent across all ONOS nodes
Mastership of Switches was not changed
Intents are consistent across all ONOS nodes
No changes were found in the flow tables
Constant State Tests Passed
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase9
Turn off a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.930999994278 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase10
Restore a link to ensure that Link Discovery is working properly
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.926119804382 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase11
Killing a switch to ensure it is discovered correctly
Deleting s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.927114009857 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase12
Adding a switch to ensure it is discovered correctly
Adding back s28
Result: Pass
Result summary for Testcase8
Compare ONOS Topology view to Mininet topology
Very crass estimate for topology discovery/convergence(note it takes about 1 seconds to read the topology from each ONOS instance): 0.916398048401 seconds, 1 tries
ONOS topology view matches Mininet topology
Result: Pass
Result summary for Testcase4
Ping across added host intents
Intents have been installed correctly and verified by pings
Result: Pass
Result summary for Testcase13
Test Cleanup
Result: Pass