Test Plan for HA Test Cases

  • HATestSanity - Results: 25 Passed, 0 Failed
  • HATestMinorityRestart - Results: 21 Passed, 4 Failed
  • HATestClusterRestart - Results: 21 Passed, 5 Failed
  • SingleInstanceHATestRestart - Results: 0 Passed, 0 Failed
  • Test HATestSanity

    ************************************

    Result summary for Testcase1

    ONOS HA Sanity test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 7256d0842bc6489eafb9fb083afaebebbc039956 (HEAD, origin/master, origin/HEAD, master)

    Author: Simon Hunt [simon@onlab.us]

    AuthorDate: Thu Dec 18 21:43:28 2014 -0800

    Commit: Simon Hunt [simon@onlab.us]

    CommitDate: Thu Dec 18 21:43:28 2014 -0800

    GUI -- removed commented out tests.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5294470787 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase14

    Leadership election tests passed(consistent view of leader across listeners and a leader was elected)

    Result: Pass

    Result summary for Testcase6

    Wait 60 seconds instead of inducing a failure

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6873118877 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    Intents are consistent with before failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Leadership election tests passed(consistent view of leader across listeners and a new leader was re-elected if applicable)

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase15

    Check that Leadership Election is still functional

    Leadership election tests passed(consistent view of leader across listeners and a new leader was elected when the old leader resigned)

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5636510849 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6355390549 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6262118816 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5777060986 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestMinorityRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart minority of ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 7256d0842bc6489eafb9fb083afaebebbc039956 (HEAD, origin/master, origin/HEAD, master)

    Author: Simon Hunt [simon@onlab.us]

    AuthorDate: Thu Dec 18 21:43:28 2014 -0800

    Commit: Simon Hunt [simon@onlab.us]

    CommitDate: Thu Dec 18 21:43:28 2014 -0800

    GUI -- removed commented out tests.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6301128864 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase14

    Leadership election tests passed(consistent view of leader across listeners and a leader was elected)

    Result: Pass

    Result summary for Testcase6

    Killing 3 ONOS nodes

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6618101597 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    The Intents changed during failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Leadership election tests passed(consistent view of leader across listeners and a new leader was re-elected if applicable)

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase15

    Check that Leadership Election is still functional

    Leadership election tests passed(consistent view of leader across listeners and a new leader was elected when the old leader resigned)

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 14 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 14.131223917 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.7968010902 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.614992857 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.6763989925 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestClusterRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart all ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit 7256d0842bc6489eafb9fb083afaebebbc039956 (HEAD, origin/master, origin/HEAD, master)

    Author: Simon Hunt [simon@onlab.us]

    AuthorDate: Thu Dec 18 21:43:28 2014 -0800

    Commit: Simon Hunt [simon@onlab.us]

    CommitDate: Thu Dec 18 21:43:28 2014 -0800

    GUI -- removed commented out tests.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 13.5538599491 seconds, 1 tries

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents are consistent across all ONOS nodes

    Flow count is consistent across all ONOS nodes

    Result: Pass

    Result summary for Testcase14

    Leadership election tests passed(consistent view of leader across listeners and a leader was elected)

    Result: Pass

    Result summary for Testcase6

    Restart entire ONOS cluster

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.6915998459 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Loss of dataplane connectivity detected

    Leadership election tests passed(consistent view of leader across listeners and a new leader was re-elected after restart)

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase15

    Check that Leadership Election is still functional

    Leadership election tests passed(consistent view of leader across listeners and a new leader was elected when the old leader resigned)

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.1553740501 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.232779026 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 63.5181200504 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s28

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    Very crass estimate for topology discovery/convergence(note it takes about 13 seconds for the test to make all the cli calls to fetch the topology from each ONOS instance): 64.5562369823 seconds, 3 tries

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test SingleInstanceHATestRestart

    ************************************