Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 52 Next »

SROnosFailure at 24 Feb 2021 14:54:38

SROnosFailure-stratum

commit 515f5f3b88135f9450b8c53c288f297c10c9d246 (HEAD -] master, origin/master, origin/HEAD)
Author: Daniel Park [dan.mcpark84@gmail.com]
AuthorDate: Mon Feb 22 17:12:20 2021 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Wed Feb 24 00:44:00 2021 +0000

Initializes gateway type of kubevirt node.
--
(cherry picked from commit 54d8baf7cf1042251067641cf1da99cbc0ae8638)

Case 1: ONOS Failure test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Building ONOS Docker image - PASS (tick)
  • 1.6 Create Cluster Config - PASS (tick)
  • 1.7 Installing Atomix via docker containers - PASS (tick)
  • 1.8 Installing ONOS via docker containers - PASS (tick)
  • 1.9 Set up ONOS secure SSH - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Configure switches in ONOS - PASS (tick)
  • 1.17 Check number of topology elements - PASS (tick)
  • 1.18 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 116
  • 1.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS (tick)
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.23 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.24 Check number of topology elements - PASS (tick)
  • 1.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - PASS (tick)
  • 1.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.28 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.29 Checking if ONOS CLI is ready - PASS (tick)
  • 1.30 Checking ONOS nodes - PASS (tick)
  • 1.31 Check number of topology elements - PASS (tick)
  • 1.32 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 116
  • 1.33 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - PASS (tick)
  • 1.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.37 Check number of topology elements - PASS (tick)
  • 1.38 Stopping Mininet - PASS (tick)
  • 1.39 Copying karaf logs - PASS (tick)

Case 2: ONOS Failure test with 4x4 Leaf-spine - FAIL

  • No labels