SRBridging at 25 Feb 2021 12:31:59
commit 515f5f3b88135f9450b8c53c288f297c10c9d246 (HEAD -] master, origin/master, origin/HEAD)
Author: Daniel Park [dan.mcpark84@gmail.com]
AuthorDate: Mon Feb 22 17:12:20 2021 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Wed Feb 24 00:44:00 2021 +0000
Initializes gateway type of kubevirt node.
--
(cherry picked from commit 54d8baf7cf1042251067641cf1da99cbc0ae8638)
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - FAIL
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Building ONOS Docker image - PASS
- 5.6 Create Cluster Config - PASS
- 5.7 Installing Atomix via docker containers - PASS
- 5.8 Installing ONOS via docker containers - PASS
- 5.9 Set up ONOS secure SSH - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Set logging levels - PASS
- 5.14 Set ONOS configurations - PASS
- 5.15 Starting Mininet Topology - PASS
- 5.16 Configure switches in ONOS - PASS
- 5.17 Check whether the flow count is >= 20 - FAIL
- Flow count looks wrong; found 0, expecting at least 20
- 5.18 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 5.19 Check whether the flow count of device device:bmv2:leaf1 >= than 20 - FAIL
- Flow count looks wrong: 0
- 5.20 Check number of topology elements - PASS
- 5.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
- 5.22 Stopping Mininet - PASS
- 5.23 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, stratum switches and 3 ONOS instances - FAIL
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Create Cluster Config - PASS
- 6.5 Installing Atomix via docker containers - PASS
- 6.6 Installing ONOS via docker containers - PASS
- 6.7 Set up ONOS secure SSH - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Configure switches in ONOS - PASS
- 6.15 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 0, expecting at least 74
- 6.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 6.17 Check whether the flow count of device device:bmv2:leaf1 >= than 37 - FAIL
- Flow count looks wrong: 0
- 6.18 Check whether the flow count of device device:bmv2:leaf2 >= than 37 - FAIL
- Flow count looks wrong: 0
- 6.19 Check number of topology elements - PASS
- 6.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.21 Stopping Mininet - PASS
- 6.22 Copying karaf logs - PASS
Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, stratum switches and 3 ONOS instances - FAIL
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Create Cluster Config - PASS
- 7.5 Installing Atomix via docker containers - PASS
- 7.6 Installing ONOS via docker containers - PASS
- 7.7 Set up ONOS secure SSH - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Configure switches in ONOS - PASS
- 7.15 Check whether the flow count is >= 64 - FAIL
- Flow count looks wrong; found 0, expecting at least 64
- 7.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 7.17 Check whether the flow count of device device:bmv2:leaf1 >= than 32 - FAIL
- Flow count looks wrong: 0
- 7.18 Check whether the flow count of device device:bmv2:leaf2 >= than 32 - FAIL
- Flow count looks wrong: 0
- 7.19 Check number of topology elements - PASS
- 7.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.22 Stopping Mininet - PASS
- 7.23 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances - FAIL
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Create Cluster Config - PASS
- 8.5 Installing Atomix via docker containers - PASS
- 8.6 Installing ONOS via docker containers - PASS
- 8.7 Set up ONOS secure SSH - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Set logging levels - PASS
- 8.12 Set ONOS configurations - PASS
- 8.13 Starting Mininet Topology - PASS
- 8.14 Configure switches in ONOS - PASS
- 8.15 Check whether the flow count is >= 212 - FAIL
- Flow count looks wrong; found 0, expecting at least 212
- 8.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 8.17 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - FAIL
- Flow count looks wrong: 0
- 8.18 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - FAIL
- Flow count looks wrong: 0
- 8.19 Check whether the flow count of device device:bmv2:leaf3 >= than 53 - FAIL
- Flow count looks wrong: 0
- 8.20 Check whether the flow count of device device:bmv2:leaf4 >= than 53 - FAIL
- Flow count looks wrong: 0
- 8.21 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 8.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS
- 8.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS
- 8.24 Stopping Mininet - PASS
- 8.25 Copying karaf logs - PASS
Case 15: Bridging test between two tagged hosts, with single ToR, stratum switches and 3 ONOS instances - FAIL
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Create Cluster Config - PASS
- 15.5 Installing Atomix via docker containers - PASS
- 15.6 Installing ONOS via docker containers - PASS
- 15.7 Set up ONOS secure SSH - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Set logging levels - PASS
- 15.12 Set ONOS configurations - PASS
- 15.13 Starting Mininet Topology - PASS
- 15.14 Configure switches in ONOS - PASS
- 15.15 Check whether the flow count is >= 20 - FAIL
- Flow count looks wrong; found 0, expecting at least 20
- 15.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 15.17 Check whether the flow count of device device:bmv2:leaf1 >= than 20 - FAIL
- Flow count looks wrong: 0
- 15.18 Check number of topology elements - PASS
- 15.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS
- 15.20 Stopping Mininet - PASS
- 15.21 Copying karaf logs - PASS
Case 16: Bridging test between two tagged hosts, with dual-homed ToR, stratum switches and 3 ONOS instances - FAIL
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Create Cluster Config - PASS
- 16.5 Installing Atomix via docker containers - PASS
- 16.6 Installing ONOS via docker containers - PASS
- 16.7 Set up ONOS secure SSH - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Set logging levels - PASS
- 16.12 Set ONOS configurations - PASS
- 16.13 Starting Mininet Topology - PASS
- 16.14 Configure switches in ONOS - PASS
- 16.15 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 0, expecting at least 74
- 16.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 16.17 Check whether the flow count of device device:bmv2:leaf1 >= than 37 - FAIL
- Flow count looks wrong: 0
- 16.18 Check whether the flow count of device device:bmv2:leaf2 >= than 37 - FAIL
- Flow count looks wrong: 0
- 16.19 Check number of topology elements - PASS
- 16.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.21 Stopping Mininet - PASS
- 16.22 Copying karaf logs - PASS
Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology, stratum switches and 3 ONOS instances - FAIL
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Create Cluster Config - PASS
- 17.5 Installing Atomix via docker containers - PASS
- 17.6 Installing ONOS via docker containers - PASS
- 17.7 Set up ONOS secure SSH - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Set logging levels - PASS
- 17.12 Set ONOS configurations - PASS
- 17.13 Starting Mininet Topology - PASS
- 17.14 Configure switches in ONOS - PASS
- 17.15 Check whether the flow count is >= 64 - FAIL
- Flow count looks wrong; found 0, expecting at least 64
- 17.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 17.17 Check whether the flow count of device device:bmv2:leaf1 >= than 32 - FAIL
- Flow count looks wrong: 0
- 17.18 Check whether the flow count of device device:bmv2:leaf2 >= than 32 - FAIL
- Flow count looks wrong: 0
- 17.19 Check number of topology elements - PASS
- 17.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.22 Stopping Mininet - PASS
- 17.23 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances - FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Create Cluster Config - PASS
- 18.5 Installing Atomix via docker containers - PASS
- 18.6 Installing ONOS via docker containers - PASS
- 18.7 Set up ONOS secure SSH - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Set logging levels - PASS
- 18.12 Set ONOS configurations - PASS
- 18.13 Starting Mininet Topology - PASS
- 18.14 Configure switches in ONOS - PASS
- 18.15 Check whether the flow count is >= 212 - FAIL
- Flow count looks wrong; found 0, expecting at least 212
- 18.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 18.17 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - FAIL
- Flow count looks wrong: 0
- 18.18 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - FAIL
- Flow count looks wrong: 0
- 18.19 Check whether the flow count of device device:bmv2:leaf3 >= than 53 - FAIL
- Flow count looks wrong: 0
- 18.20 Check whether the flow count of device device:bmv2:leaf4 >= than 53 - FAIL
- Flow count looks wrong: 0
- 18.21 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 18.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.24 Stopping Mininet - PASS
- 18.25 Copying karaf logs - PASS
Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR, stratum switches and 3 ONOS instances - FAIL
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Create Cluster Config - PASS
- 25.5 Installing Atomix via docker containers - PASS
- 25.6 Installing ONOS via docker containers - PASS
- 25.7 Set up ONOS secure SSH - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Set logging levels - PASS
- 25.12 Set ONOS configurations - PASS
- 25.13 Starting Mininet Topology - PASS
- 25.14 Configure switches in ONOS - PASS
- 25.15 Check whether the flow count is >= 20 - FAIL
- Flow count looks wrong; found 0, expecting at least 20
- 25.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 25.17 Check whether the flow count of device device:bmv2:leaf1 >= than 20 - FAIL
- Flow count looks wrong: 0
- 25.18 Check number of topology elements - PASS
- 25.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS
- 25.20 Stopping Mininet - PASS
- 25.21 Copying karaf logs - PASS
Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, stratum switches and 3 ONOS instances - FAIL
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Create Cluster Config - PASS
- 26.5 Installing Atomix via docker containers - PASS
- 26.6 Installing ONOS via docker containers - PASS
- 26.7 Set up ONOS secure SSH - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Set logging levels - PASS
- 26.12 Set ONOS configurations - PASS
- 26.13 Starting Mininet Topology - PASS
- 26.14 Configure switches in ONOS - PASS
- 26.15 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 0, expecting at least 74
- 26.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 26.17 Check whether the flow count of device device:bmv2:leaf1 >= than 37 - FAIL
- Flow count looks wrong: 0
- 26.18 Check whether the flow count of device device:bmv2:leaf2 >= than 37 - FAIL
- Flow count looks wrong: 0
- 26.19 Check number of topology elements - PASS
- 26.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
- 26.21 Stopping Mininet - PASS
- 26.22 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, stratum switches and 3 ONOS instances - FAIL
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Create Cluster Config - PASS
- 27.5 Installing Atomix via docker containers - PASS
- 27.6 Installing ONOS via docker containers - PASS
- 27.7 Set up ONOS secure SSH - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Set logging levels - PASS
- 27.12 Set ONOS configurations - PASS
- 27.13 Starting Mininet Topology - PASS
- 27.14 Configure switches in ONOS - PASS
- 27.15 Check whether the flow count is >= 64 - FAIL
- Flow count looks wrong; found 0, expecting at least 64
- 27.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 27.17 Check whether the flow count of device device:bmv2:leaf1 >= than 32 - FAIL
- Flow count looks wrong: 0
- 27.18 Check whether the flow count of device device:bmv2:leaf2 >= than 32 - FAIL
- Flow count looks wrong: 0
- 27.19 Check number of topology elements - PASS
- 27.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.22 Stopping Mininet - PASS
- 27.23 Copying karaf logs - PASS
Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances - FAIL
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Create Cluster Config - PASS
- 28.5 Installing Atomix via docker containers - PASS
- 28.6 Installing ONOS via docker containers - PASS
- 28.7 Set up ONOS secure SSH - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Set logging levels - PASS
- 28.12 Set ONOS configurations - PASS
- 28.13 Starting Mininet Topology - PASS
- 28.14 Configure switches in ONOS - PASS
- 28.15 Check whether the flow count is >= 212 - FAIL
- Flow count looks wrong; found 0, expecting at least 212
- 28.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 28.17 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - FAIL
- Flow count looks wrong: 0
- 28.18 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - FAIL
- Flow count looks wrong: 0
- 28.19 Check whether the flow count of device device:bmv2:leaf3 >= than 53 - FAIL
- Flow count looks wrong: 0
- 28.20 Check whether the flow count of device device:bmv2:leaf4 >= than 53 - FAIL
- Flow count looks wrong: 0
- 28.21 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 28.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS
- 28.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS
- 28.24 Stopping Mininet - PASS
- 28.25 Copying karaf logs - PASS