SRBridging at 24 Mar 2021 03:47:29

SRBridging-stratum

commit 517597a84982c38883e552771bbb105756b73aaa (HEAD -] master, origin/master, origin/HEAD)
Author: Jian Li [pyguni@gmail.com]
AuthorDate: Mon Mar 22 11:04:52 2021 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Mon Mar 22 07:13:54 2021 +0000

Dynamically add or remove gateway node according to GW annotation
--
(cherry picked from commit 91358d6126e13adcc4e4b8c7bbd46179fb4c2913)

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - FAIL

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Building ONOS Docker image - PASS (tick)
  • 5.6 Create Cluster Config - PASS (tick)
  • 5.7 Installing Atomix via docker containers - PASS (tick)
  • 5.8 Installing ONOS via docker containers - PASS (tick)
  • 5.9 Set up ONOS secure SSH - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Set logging levels - PASS (tick)
  • 5.14 Set ONOS configurations - PASS (tick)
  • 5.15 Starting Mininet Topology - PASS (tick)
  • 5.16 Configure switches in ONOS - PASS (tick)
  • 5.17 Check whether the flow count is >= 20 - FAIL (error)
    • Flow count looks wrong; found 3, expecting at least 20
  • 5.18 Check whether all flow status are ADDED - PASS (tick)
  • 5.19 Check whether the flow count of device device:leaf1 >= than 20 - FAIL (error)
    • Flow count looks wrong: 3
  • 5.20 Check number of topology elements - PASS (tick)
  • 5.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.22 Stopping Mininet - PASS (tick)
  • 5.23 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, stratum switches and 3 ONOS instances - FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Create Cluster Config - PASS (tick)
  • 6.5 Installing Atomix via docker containers - PASS (tick)
  • 6.6 Installing ONOS via docker containers - PASS (tick)
  • 6.7 Set up ONOS secure SSH - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Set logging levels - PASS (tick)
  • 6.12 Set ONOS configurations - PASS (tick)
  • 6.13 Starting Mininet Topology - PASS (tick)
  • 6.14 Configure switches in ONOS - PASS (tick)
  • 6.15 Check whether the flow count is >= 74 - FAIL (error)
    • Flow count looks wrong; found 6, expecting at least 74
  • 6.16 Check whether all flow status are ADDED - PASS (tick)
  • 6.17 Check whether the flow count of device device:leaf1 >= than 37 - FAIL (error)
    • Flow count looks wrong: 6
  • 6.18 Check whether the flow count of device device:leaf2 >= than 37 - FAIL (error)
    • Flow count looks wrong: 6
  • 6.19 Check number of topology elements - PASS (tick)
  • 6.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.21 Stopping Mininet - PASS (tick)
  • 6.22 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, stratum switches and 3 ONOS instances - FAIL

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Create Cluster Config - PASS (tick)
  • 7.5 Installing Atomix via docker containers - PASS (tick)
  • 7.6 Installing ONOS via docker containers - PASS (tick)
  • 7.7 Set up ONOS secure SSH - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Set logging levels - PASS (tick)
  • 7.12 Set ONOS configurations - PASS (tick)
  • 7.13 Starting Mininet Topology - PASS (tick)
  • 7.14 Configure switches in ONOS - PASS (tick)
  • 7.15 Check whether the flow count is >= 64 - FAIL (error)
    • Flow count looks wrong; found 12, expecting at least 64
  • 7.16 Check whether all flow status are ADDED - PASS (tick)
  • 7.17 Check whether the flow count of device device:leaf1 >= than 32 - FAIL (error)
    • Flow count looks wrong: 12
  • 7.18 Check whether the flow count of device device:leaf2 >= than 32 - FAIL (error)
    • Flow count looks wrong: 12
  • 7.19 Check number of topology elements - PASS (tick)
  • 7.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - FAIL (error)
    • IP connectivity failed
  • 7.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - FAIL (error)
    • IP connectivity failed
  • 7.22 Stopping Mininet - PASS (tick)
  • 7.23 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances - FAIL