SRBridging at 27 Mar 2021 11:07:26
commit 5fbf6bfe080b602de7263f1549090eef490c09ce (HEAD)
Author: Andrea Campanella [andrea@opennetworking.org]
AuthorDate: Fri Mar 26 10:34:30 2021 +0100
Commit: Andrea Campanella [andrea@opennetworking.org]
CommitDate: Fri Mar 26 21:03:51 2021 +0100
[VOL-3922] Invalidating the pipeliner cache if the driver for a device changes
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Set logging levels - PASS
- 5.14 Set ONOS configurations - PASS
- 5.15 Starting Mininet Topology - PASS
- 5.16 Check whether the flow count is >= 28 - PASS
- 5.17 Check whether all flow status are ADDED - PASS
- 5.18 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS
- 5.19 Check number of topology elements - PASS
- 5.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
- 5.21 Stopping Mininet - PASS
- 5.22 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 34, expecting at least 74
- 6.15 Check whether all flow status are ADDED - PASS
- 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 17
- 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL
- Flow count looks wrong: 17
- 6.18 Check number of topology elements - PASS
- 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL
- IP connectivity failed
- 6.20 Stopping Mininet - PASS
- 6.21 Copying karaf logs - PASS
Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Check whether the flow count is >= 74 - PASS
- 7.15 Check whether all flow status are ADDED - PASS
- 7.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 7.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 7.18 Check number of topology elements - PASS
- 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.21 Stopping Mininet - PASS
- 7.22 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Set logging levels - PASS
- 8.12 Set ONOS configurations - PASS
- 8.13 Starting Mininet Topology - PASS
- 8.14 Check whether the flow count is >= 212 - PASS
- 8.15 Check whether all flow status are ADDED - PASS
- 8.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS
- 8.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 8.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS
- 8.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS
- 8.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 8.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS
- 8.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS
- 8.23 Stopping Mininet - PASS
- 8.24 Copying karaf logs - PASS