Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 238 Next »

SRBridging at 27 Mar 2021 11:07:26

SRBridging

commit 5fbf6bfe080b602de7263f1549090eef490c09ce (HEAD)
Author: Andrea Campanella [andrea@opennetworking.org]
AuthorDate: Fri Mar 26 10:34:30 2021 +0100
Commit: Andrea Campanella [andrea@opennetworking.org]
CommitDate: Fri Mar 26 21:03:51 2021 +0100

[VOL-3922] Invalidating the pipeliner cache if the driver for a device changes

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Set logging levels - PASS (tick)
  • 5.14 Set ONOS configurations - PASS (tick)
  • 5.15 Starting Mininet Topology - PASS (tick)
  • 5.16 Check whether the flow count is >= 28 - PASS (tick)
  • 5.17 Check whether all flow status are ADDED - PASS (tick)
  • 5.18 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)
  • 5.19 Check number of topology elements - PASS (tick)
  • 5.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.21 Stopping Mininet - PASS (tick)
  • 5.22 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Set logging levels - PASS (tick)
  • 6.12 Set ONOS configurations - PASS (tick)
  • 6.13 Starting Mininet Topology - PASS (tick)
  • 6.14 Check whether the flow count is >= 74 - FAIL (error)
    • Flow count looks wrong; found 34, expecting at least 74
  • 6.15 Check whether all flow status are ADDED - PASS (tick)
  • 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
    • Flow count looks wrong: 17
  • 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
    • Flow count looks wrong: 17
  • 6.18 Check number of topology elements - PASS (tick)
  • 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.20 Stopping Mininet - PASS (tick)
  • 6.21 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Set logging levels - PASS (tick)
  • 7.12 Set ONOS configurations - PASS (tick)
  • 7.13 Starting Mininet Topology - PASS (tick)
  • 7.14 Check whether the flow count is >= 74 - PASS (tick)
  • 7.15 Check whether all flow status are ADDED - PASS (tick)
  • 7.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 7.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 7.18 Check number of topology elements - PASS (tick)
  • 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.21 Stopping Mininet - PASS (tick)
  • 7.22 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Set logging levels - PASS (tick)
  • 8.12 Set ONOS configurations - PASS (tick)
  • 8.13 Starting Mininet Topology - PASS (tick)
  • 8.14 Check whether the flow count is >= 212 - PASS (tick)
  • 8.15 Check whether all flow status are ADDED - PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)
  • 8.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)
  • 8.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)
  • 8.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 8.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.23 Stopping Mininet - PASS (tick)
  • 8.24 Copying karaf logs - PASS (tick)

Case 15: Bridging test between two tagged hosts, with single ToR, ovs switches and 3 ONOS instances - FAIL

  • No labels