SRDhcprelay at 25 Mar 2018 00:11:23

SRDhcprelay

commit 09c6699da398a521e02049917357301246a40542 (HEAD -] onos-1.11, origin/onos-1.11)
Author: Charles Chan [rascov@gmail.com]
AuthorDate: Fri Mar 9 15:53:44 2018 -0800
Commit: Charles Chan [rascov@gmail.com]
CommitDate: Thu Mar 15 00:05:44 2018 -0700

Fix NPE caused by RoutingRulePopulator not initiated before linkHandler.init()

Case 1: DHCP v4 tests with 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - PASS

  • 1.1 Constructing test variables - No Result (warning)
  • 1.2 Constructing test variables - PASS (tick)
  • 1.3 Apply cell to environment - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing ONOS package - PASS (tick)
  • 1.7 Set up ONOS secure SSH - PASS (tick)
  • 1.8 Checking ONOS service - PASS (tick)
  • 1.9 Starting ONOS CLI sessions - PASS (tick)
  • 1.10 Starting Mininet Topology - PASS (tick)
  • 1.11 Verify host IP address assignment in ONOS - PASS (tick)
  • 1.12 Verify IP address assignment from hosts - PASS (tick)
  • 1.13 Stopping Mininet - PASS (tick)
  • 1.14 Copying karaf logs - PASS (tick)

Case 2: DHCP v4 tests with 4 clients attached to switch directly and 1 server attached to switch indirectly (via gateway), with 3 ONOS instances - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling ONOS package - PASS (tick)
  • 2.3 Installing ONOS package - PASS (tick)
  • 2.4 Set up ONOS secure SSH - PASS (tick)
  • 2.5 Checking ONOS service - PASS (tick)
  • 2.6 Starting ONOS CLI sessions - PASS (tick)
  • 2.7 Starting Mininet Topology - PASS (tick)
  • 2.8 Verify host IP address assignment in ONOS - FAIL (error)
    • Verify ONOS host IP failed
  • 2.9 Verify IP address assignment from hosts - FAIL (error)
    • Verify network host IP failed
  • 2.10 Stopping Mininet - PASS (tick)
  • 2.11 Copying karaf logs - PASS (tick)

Case 11: DHCP v6 tests with 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - FAIL

  • 11.1 Apply cell to environment - PASS (tick)
  • 11.2 Uninstalling ONOS package - PASS (tick)
  • 11.3 Installing ONOS package - PASS (tick)
  • 11.4 Set up ONOS secure SSH - PASS (tick)
  • 11.5 Checking ONOS service - PASS (tick)
  • 11.6 Starting ONOS CLI sessions - PASS (tick)
  • 11.7 Starting Mininet Topology - PASS (tick)
  • 11.8 Verify host IP address assignment in ONOS - FAIL (error)
    • Verify ONOS host IP failed
  • 11.9 Verify IP address assignment from hosts - FAIL (error)
    • Verify network host IP failed
  • 11.10 Stopping Mininet - PASS (tick)
  • 11.11 Copying karaf logs - PASS (tick)

Case 12: DHCP v6 tests with 4 clients attached to switch directly and 1 server attached to switch indirectly (via gateway), with 3 ONOS instances - FAIL

  • 12.1 Apply cell to environment - PASS (tick)
  • 12.2 Uninstalling ONOS package - PASS (tick)
  • 12.3 Installing ONOS package - PASS (tick)
  • 12.4 Set up ONOS secure SSH - PASS (tick)
  • 12.5 Checking ONOS service - PASS (tick)
  • 12.6 Starting ONOS CLI sessions - PASS (tick)
  • 12.7 Starting Mininet Topology - PASS (tick)
  • 12.8 Verify host IP address assignment in ONOS - FAIL (error)
    • Verify ONOS host IP failed
  • 12.9 Verify IP address assignment from hosts - FAIL (error)
    • Verify network host IP failed
  • 12.10 Stopping Mininet - PASS (tick)
  • 12.11 Copying karaf logs - PASS (tick)

Case 21: DHCP v4 tests with tagged hosts: 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - PASS

  • 21.1 Apply cell to environment - PASS (tick)
  • 21.2 Uninstalling ONOS package - PASS (tick)
  • 21.3 Installing ONOS package - PASS (tick)
  • 21.4 Set up ONOS secure SSH - PASS (tick)
  • 21.5 Checking ONOS service - PASS (tick)
  • 21.6 Starting ONOS CLI sessions - PASS (tick)
  • 21.7 Starting Mininet Topology - PASS (tick)
  • 21.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 21.9 Verify IP address assignment from hosts - PASS (tick)
  • 21.10 Stopping Mininet - PASS (tick)
  • 21.11 Copying karaf logs - PASS (tick)

Case 22: DHCP v4 tests with 4 clients attached to switch directly and 1 server attached to switch indirectly (via gateway), with 3 ONOS instances - FAIL

  • 22.1 Apply cell to environment - PASS (tick)
  • 22.2 Uninstalling ONOS package - PASS (tick)
  • 22.3 Installing ONOS package - PASS (tick)
  • 22.4 Set up ONOS secure SSH - PASS (tick)
  • 22.5 Checking ONOS service - PASS (tick)
  • 22.6 Starting ONOS CLI sessions - PASS (tick)
  • 22.7 Starting Mininet Topology - PASS (tick)
  • 22.8 Verify host IP address assignment in ONOS - FAIL (error)
    • Verify ONOS host IP failed
  • 22.9 Verify IP address assignment from hosts - FAIL (error)
    • Verify network host IP failed
  • 22.10 Stopping Mininet - PASS (tick)
  • 22.11 Copying karaf logs - PASS (tick)

Case 31: DHCP v6 tests with tagged hosts: 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - FAIL

  • 31.1 Apply cell to environment - PASS (tick)
  • 31.2 Uninstalling ONOS package - PASS (tick)
  • 31.3 Installing ONOS package - PASS (tick)
  • 31.4 Set up ONOS secure SSH - PASS (tick)
  • 31.5 Checking ONOS service - PASS (tick)
  • 31.6 Starting ONOS CLI sessions - PASS (tick)
  • 31.7 Starting Mininet Topology - PASS (tick)
  • 31.8 Verify host IP address assignment in ONOS - FAIL (error)
    • Verify ONOS host IP failed
  • 31.9 Verify IP address assignment from hosts - FAIL (error)
    • Verify network host IP failed
  • 31.10 Stopping Mininet - PASS (tick)
  • 31.11 Copying karaf logs - PASS (tick)

Case 41: DHCP v4 tests with dual-homed hosts: 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - PASS

  • 41.1 Apply cell to environment - PASS (tick)
  • 41.2 Uninstalling ONOS package - PASS (tick)
  • 41.3 Installing ONOS package - PASS (tick)
  • 41.4 Set up ONOS secure SSH - PASS (tick)
  • 41.5 Checking ONOS service - PASS (tick)
  • 41.6 Starting ONOS CLI sessions - PASS (tick)
  • 41.7 Starting Mininet Topology - PASS (tick)
  • 41.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 41.9 Verify IP address assignment from hosts - PASS (tick)
  • 41.10 Stopping Mininet - PASS (tick)
  • 41.11 Copying karaf logs - PASS (tick)

Case 51: DHCP v6 tests with dual-homed hosts: 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - FAIL

  • 51.1 Apply cell to environment - PASS (tick)
  • 51.2 Uninstalling ONOS package - PASS (tick)
  • 51.3 Installing ONOS package - PASS (tick)
  • 51.4 Set up ONOS secure SSH - PASS (tick)
  • 51.5 Checking ONOS service - PASS (tick)
  • 51.6 Starting ONOS CLI sessions - PASS (tick)
  • 51.7 Starting Mininet Topology - PASS (tick)
  • 51.8 Verify host IP address assignment in ONOS - FAIL (error)
    • Verify ONOS host IP failed
  • 51.9 Verify IP address assignment from hosts - FAIL (error)
    • Verify network host IP failed
  • 51.10 Stopping Mininet - PASS (tick)
  • 51.11 Copying karaf logs - PASS (tick)

Case 61: DHCP v4 tests with dual-homed tagged hosts: 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - PASS

  • 61.1 Apply cell to environment - PASS (tick)
  • 61.2 Uninstalling ONOS package - PASS (tick)
  • 61.3 Installing ONOS package - PASS (tick)
  • 61.4 Set up ONOS secure SSH - PASS (tick)
  • 61.5 Checking ONOS service - PASS (tick)
  • 61.6 Starting ONOS CLI sessions - PASS (tick)
  • 61.7 Starting Mininet Topology - PASS (tick)
  • 61.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 61.9 Verify IP address assignment from hosts - PASS (tick)
  • 61.10 Stopping Mininet - PASS (tick)
  • 61.11 Copying karaf logs - PASS (tick)

Case 71: DHCP v6 tests with dual-homed tagged hosts: 4 clients attached to switch directly and 1 server attached to switch directly, with 3 ONOS instances - FAIL

  • 71.1 Apply cell to environment - PASS (tick)
  • 71.2 Uninstalling ONOS package - PASS (tick)
  • 71.3 Installing ONOS package - PASS (tick)
  • 71.4 Set up ONOS secure SSH - PASS (tick)
  • 71.5 Checking ONOS service - PASS (tick)
  • 71.6 Starting ONOS CLI sessions - PASS (tick)
  • 71.7 Starting Mininet Topology - PASS (tick)
  • 71.8 Verify host IP address assignment in ONOS - FAIL (error)
    • Verify ONOS host IP failed
  • 71.9 Verify IP address assignment from hosts - FAIL (error)
    • Verify network host IP failed
  • 71.10 Stopping Mininet - PASS (tick)
  • 71.11 Copying karaf logs - PASS (tick)