Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 233 Next »

SRDynamicConf at 04 Apr 2021 19:19:44

SRDynamicConf

commit d88e4aa563cbb8fbe8f7537024b9ba6158806891 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Mon Mar 29 22:07:32 2021 +0200
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Wed Mar 31 06:52:21 2021 +0000

Enable read counters with table entries for stratum-tofino driver
--
(cherry picked from commit e4d1294c3006079f37bc493258df60a51698e338)

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Set logging levels - PASS (tick)
  • 13.14 Set ONOS configurations - PASS (tick)
  • 13.15 Starting Mininet Topology - PASS (tick)
  • 13.16 Check whether the flow count is >= 104 - PASS (tick)
  • 13.17 Check whether all flow status are ADDED - PASS (tick)
  • 13.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.19 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 13.20 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 13.21 Check whether the flow count is >= 104 - PASS (tick)
  • 13.22 Check whether all flow status are ADDED - PASS (tick)
  • 13.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.24 Stopping Mininet - PASS (tick)
  • 13.25 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Set logging levels - PASS (tick)
  • 23.12 Set ONOS configurations - PASS (tick)
  • 23.13 Starting Mininet Topology - PASS (tick)
  • 23.14 Check whether the flow count is >= 106 - PASS (tick)
  • 23.15 Check whether all flow status are ADDED - PASS (tick)
  • 23.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.18 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)
  • 23.19 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)
  • 23.20 Check whether the flow count is >= 106 - PASS (tick)
  • 23.21 Check whether all flow status are ADDED - PASS (tick)
  • 23.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.24 Stopping Mininet - PASS (tick)
  • 23.25 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Set logging levels - PASS (tick)
  • 33.12 Set ONOS configurations - PASS (tick)
  • 33.13 Starting Mininet Topology - PASS (tick)
  • 33.14 Check whether the flow count is >= 104 - PASS (tick)
  • 33.15 Check whether all flow status are ADDED - PASS (tick)
  • 33.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.18 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 33.19 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 33.20 Check whether the flow count is >= 104 - PASS (tick)
  • 33.21 Check whether all flow status are ADDED - PASS (tick)
  • 33.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.24 Stopping Mininet - PASS (tick)
  • 33.25 Copying karaf logs - PASS (tick)

Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling Atomix - PASS (tick)
  • 43.3 Uninstalling ONOS package - PASS (tick)
  • 43.4 Installing Atomix - PASS (tick)
  • 43.5 Installing ONOS package - PASS (tick)
  • 43.6 Set up ONOS secure SSH - PASS (tick)
  • 43.7 Checking ONOS service - PASS (tick)
  • 43.8 Starting ONOS CLI sessions - PASS (tick)
  • 43.9 Checking ONOS nodes - PASS (tick)
  • 43.10 Checking ONOS applications - PASS (tick)
  • 43.11 Set logging levels - PASS (tick)
  • 43.12 Set ONOS configurations - PASS (tick)
  • 43.13 Starting Mininet Topology - PASS (tick)
  • 43.14 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 72, expecting at least 104
  • 43.15 Check whether all flow status are ADDED - PASS (tick)
  • 43.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - FAIL (error)
    • IP connectivity failed
  • 43.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - FAIL (error)
    • IP connectivity failed
  • 43.18 Check whether the flow count of device of:0000000000000001 >= than 52 - FAIL (error)
    • Flow count looks wrong: 18
  • 43.19 Check whether the flow count of device of:0000000000000002 >= than 52 - FAIL (error)
    • Flow count looks wrong: 18
  • 43.20 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 72, expecting at least 104
  • 43.21 Check whether all flow status are ADDED - PASS (tick)
  • 43.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - FAIL (error)
    • IP connectivity failed
  • 43.24 Stopping Mininet - PASS (tick)
  • 43.25 Copying karaf logs - PASS (tick)

Case 53: Changing port configuration from untagged 10 to tagged 20 with native 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling Atomix - PASS (tick)
  • 53.3 Uninstalling ONOS package - PASS (tick)
  • 53.4 Installing Atomix - PASS (tick)
  • 53.5 Installing ONOS package - PASS (tick)
  • 53.6 Set up ONOS secure SSH - PASS (tick)
  • 53.7 Checking ONOS service - PASS (tick)
  • 53.8 Starting ONOS CLI sessions - PASS (tick)
  • 53.9 Checking ONOS nodes - PASS (tick)
  • 53.10 Checking ONOS applications - PASS (tick)
  • 53.11 Set logging levels - PASS (tick)
  • 53.12 Set ONOS configurations - PASS (tick)
  • 53.13 Starting Mininet Topology - PASS (tick)
  • 53.14 Check whether the flow count is >= 104 - PASS (tick)
  • 53.15 Check whether all flow status are ADDED - PASS (tick)
  • 53.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.18 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 53.19 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 53.20 Check whether the flow count is >= 104 - PASS (tick)
  • 53.21 Check whether all flow status are ADDED - PASS (tick)
  • 53.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.24 Stopping Mininet - PASS (tick)
  • 53.25 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling Atomix - PASS (tick)
  • 63.3 Uninstalling ONOS package - PASS (tick)
  • 63.4 Installing Atomix - PASS (tick)
  • 63.5 Installing ONOS package - PASS (tick)
  • 63.6 Set up ONOS secure SSH - PASS (tick)
  • 63.7 Checking ONOS service - PASS (tick)
  • 63.8 Starting ONOS CLI sessions - PASS (tick)
  • 63.9 Checking ONOS nodes - PASS (tick)
  • 63.10 Checking ONOS applications - PASS (tick)
  • 63.11 Set logging levels - PASS (tick)
  • 63.12 Set ONOS configurations - PASS (tick)
  • 63.13 Starting Mininet Topology - PASS (tick)
  • 63.14 Check whether the flow count is >= 104 - PASS (tick)
  • 63.15 Check whether all flow status are ADDED - PASS (tick)
  • 63.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)
  • 63.18 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 63.19 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 63.20 Check whether the flow count is >= 104 - PASS (tick)
  • 63.21 Check whether all flow status are ADDED - PASS (tick)
  • 63.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.24 Stopping Mininet - PASS (tick)
  • 63.25 Copying karaf logs - PASS (tick)

Case 73: Changing port configuration from tagged 10 to untagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling Atomix - PASS (tick)
  • 73.3 Uninstalling ONOS package - PASS (tick)
  • 73.4 Installing Atomix - PASS (tick)
  • 73.5 Installing ONOS package - PASS (tick)
  • 73.6 Set up ONOS secure SSH - PASS (tick)
  • 73.7 Checking ONOS service - PASS (tick)
  • 73.8 Starting ONOS CLI sessions - PASS (tick)
  • 73.9 Checking ONOS nodes - PASS (tick)
  • 73.10 Checking ONOS applications - PASS (tick)
  • 73.11 Set logging levels - PASS (tick)
  • 73.12 Set ONOS configurations - PASS (tick)
  • 73.13 Starting Mininet Topology - PASS (tick)
  • 73.14 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 68, expecting at least 106
  • 73.15 Check whether all flow status are ADDED - PASS (tick)
  • 73.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - FAIL (error)
    • IP connectivity failed
  • 73.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - FAIL (error)
    • IP connectivity failed
  • 73.18 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL (error)
    • Flow count looks wrong: 17
  • 73.19 Check whether the flow count of device of:0000000000000002 >= than 53 - FAIL (error)
    • Flow count looks wrong: 17
  • 73.20 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 73, expecting at least 106
  • 73.21 Check whether all flow status are ADDED - PASS (tick)
  • 73.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - FAIL (error)
    • IP connectivity failed
  • 73.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - FAIL (error)
    • IP connectivity failed
  • 73.24 Stopping Mininet - PASS (tick)
  • 73.25 Copying karaf logs - PASS (tick)

Case 83: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling Atomix - PASS (tick)
  • 83.3 Uninstalling ONOS package - PASS (tick)
  • 83.4 Installing Atomix - PASS (tick)
  • 83.5 Installing ONOS package - PASS (tick)
  • 83.6 Set up ONOS secure SSH - PASS (tick)
  • 83.7 Checking ONOS service - PASS (tick)
  • 83.8 Starting ONOS CLI sessions - PASS (tick)
  • 83.9 Checking ONOS nodes - PASS (tick)
  • 83.10 Checking ONOS applications - PASS (tick)
  • 83.11 Set logging levels - PASS (tick)
  • 83.12 Set ONOS configurations - PASS (tick)
  • 83.13 Starting Mininet Topology - PASS (tick)
  • 83.14 Check whether the flow count is >= 104 - PASS (tick)
  • 83.15 Check whether all flow status are ADDED - PASS (tick)
  • 83.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)
  • 83.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.18 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 83.19 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 83.20 Check whether the flow count is >= 104 - PASS (tick)
  • 83.21 Check whether all flow status are ADDED - PASS (tick)
  • 83.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.24 Stopping Mininet - PASS (tick)
  • 83.25 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling Atomix - PASS (tick)
  • 93.3 Uninstalling ONOS package - PASS (tick)
  • 93.4 Installing Atomix - PASS (tick)
  • 93.5 Installing ONOS package - PASS (tick)
  • 93.6 Set up ONOS secure SSH - PASS (tick)
  • 93.7 Checking ONOS service - PASS (tick)
  • 93.8 Starting ONOS CLI sessions - PASS (tick)
  • 93.9 Checking ONOS nodes - PASS (tick)
  • 93.10 Checking ONOS applications - PASS (tick)
  • 93.11 Set logging levels - PASS (tick)
  • 93.12 Set ONOS configurations - PASS (tick)
  • 93.13 Starting Mininet Topology - PASS (tick)
  • 93.14 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 68, expecting at least 106
  • 93.15 Check whether all flow status are ADDED - PASS (tick)
  • 93.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - FAIL (error)
    • IP connectivity failed
  • 93.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - FAIL (error)
    • IP connectivity failed
  • 93.18 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL (error)
    • Flow count looks wrong: 17
  • 93.19 Check whether the flow count of device of:0000000000000002 >= than 53 - FAIL (error)
    • Flow count looks wrong: 17
  • 93.20 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 90, expecting at least 106
  • 93.21 Check whether all flow status are ADDED - PASS (tick)
  • 93.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - FAIL (error)
    • IP connectivity failed
  • 93.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.24 Stopping Mininet - PASS (tick)
  • 93.25 Copying karaf logs - PASS (tick)

Case 103: Changing port configuration from tagged 10 and native 20 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling Atomix - PASS (tick)
  • 103.3 Uninstalling ONOS package - PASS (tick)
  • 103.4 Installing Atomix - PASS (tick)
  • 103.5 Installing ONOS package - PASS (tick)
  • 103.6 Set up ONOS secure SSH - PASS (tick)
  • 103.7 Checking ONOS service - PASS (tick)
  • 103.8 Starting ONOS CLI sessions - PASS (tick)
  • 103.9 Checking ONOS nodes - PASS (tick)
  • 103.10 Checking ONOS applications - PASS (tick)
  • 103.11 Set logging levels - PASS (tick)
  • 103.12 Set ONOS configurations - PASS (tick)
  • 103.13 Starting Mininet Topology - PASS (tick)
  • 103.14 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 68, expecting at least 104
  • 103.15 Check whether all flow status are ADDED - PASS (tick)
  • 103.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - FAIL (error)
    • IP connectivity failed
  • 103.17 Check whether the flow count of device of:0000000000000001 >= than 52 - FAIL (error)
    • Flow count looks wrong: 17
  • 103.18 Check whether the flow count of device of:0000000000000002 >= than 52 - FAIL (error)
    • Flow count looks wrong: 17
  • 103.19 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 68, expecting at least 104
  • 103.20 Check whether all flow status are ADDED - PASS (tick)
  • 103.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - FAIL (error)
    • IP connectivity failed
  • 103.22 Stopping Mininet - PASS (tick)
  • 103.23 Copying karaf logs - PASS (tick)

Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Set logging levels - PASS (tick)
  • 113.12 Set ONOS configurations - PASS (tick)
  • 113.13 Starting Mininet Topology - PASS (tick)
  • 113.14 Check whether the flow count is >= 104 - PASS (tick)
  • 113.15 Check whether all flow status are ADDED - PASS (tick)
  • 113.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.18 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 113.19 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 113.20 Check whether the flow count is >= 104 - PASS (tick)
  • 113.21 Check whether all flow status are ADDED - PASS (tick)
  • 113.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.23 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.24 Stopping Mininet - PASS (tick)
  • 113.25 Copying karaf logs - PASS (tick)

Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Set logging levels - PASS (tick)
  • 123.12 Set ONOS configurations - PASS (tick)
  • 123.13 Starting Mininet Topology - PASS (tick)
  • 123.14 Check whether the flow count is >= 104 - PASS (tick)
  • 123.15 Check whether all flow status are ADDED - PASS (tick)
  • 123.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.18 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 123.19 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 123.20 Check whether the flow count is >= 104 - PASS (tick)
  • 123.21 Check whether all flow status are ADDED - PASS (tick)
  • 123.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.24 Stopping Mininet - PASS (tick)
  • 123.25 Copying karaf logs - PASS (tick)

Case 133: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 133.1 Apply cell to environment - PASS (tick)
  • 133.2 Uninstalling Atomix - PASS (tick)
  • 133.3 Uninstalling ONOS package - PASS (tick)
  • 133.4 Installing Atomix - PASS (tick)
  • 133.5 Installing ONOS package - PASS (tick)
  • 133.6 Set up ONOS secure SSH - PASS (tick)
  • 133.7 Checking ONOS service - PASS (tick)
  • 133.8 Starting ONOS CLI sessions - PASS (tick)
  • 133.9 Checking ONOS nodes - PASS (tick)
  • 133.10 Checking ONOS applications - PASS (tick)
  • 133.11 Set logging levels - PASS (tick)
  • 133.12 Set ONOS configurations - PASS (tick)
  • 133.13 Starting Mininet Topology - PASS (tick)
  • 133.14 Check whether the flow count is >= 104 - PASS (tick)
  • 133.15 Check whether all flow status are ADDED - PASS (tick)
  • 133.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS (tick)
  • 133.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS (tick)
  • 133.18 Check whether the flow count of device of:0000000000000001 >= than 52 - PASS (tick)
  • 133.19 Check whether the flow count of device of:0000000000000002 >= than 52 - PASS (tick)
  • 133.20 Check whether the flow count is >= 104 - PASS (tick)
  • 133.21 Check whether all flow status are ADDED - PASS (tick)
  • 133.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS (tick)
  • 133.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS (tick)
  • 133.24 Stopping Mininet - PASS (tick)
  • 133.25 Copying karaf logs - PASS (tick)

Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • No labels