Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 51 Next »

SRClusterRestart at 11 Apr 2021 18:02:57

SRClusterRestart

commit d88e4aa563cbb8fbe8f7537024b9ba6158806891 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Mon Mar 29 22:07:32 2021 +0200
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Wed Mar 31 06:52:21 2021 +0000

Enable read counters with table entries for stratum-tofino driver
--
(cherry picked from commit e4d1294c3006079f37bc493258df60a51698e338)

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is >= 116 - PASS (tick)
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.21 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.25 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.26 Checking if ONOS CLI is ready - PASS (tick)
  • 1.27 Checking if ONOS CLI is ready - PASS (tick)
  • 1.28 Checking if ONOS CLI is ready - PASS (tick)
  • 1.29 Checking ONOS nodes - PASS (tick)
  • 1.30 Check number of topology elements - PASS (tick)
  • 1.31 Check whether the flow count is >= 116 - PASS (tick)
  • 1.32 Check whether all flow status are ADDED - PASS (tick)
  • 1.33 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.36 Stopping Mininet - PASS (tick)
  • 1.37 Copying karaf logs - PASS (tick)

Case 2: Cluster Restart test with 4x4 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Set logging levels - PASS (tick)
  • 2.13 Set ONOS configurations - PASS (tick)
  • 2.14 Starting Mininet Topology - PASS (tick)
  • 2.15 Check whether the flow count is >= 350 - PASS (tick)
  • 2.16 Check whether all flow status are ADDED - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.20 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.24 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.25 Checking if ONOS CLI is ready - PASS (tick)
  • 2.26 Checking if ONOS CLI is ready - PASS (tick)
  • 2.27 Checking if ONOS CLI is ready - PASS (tick)
  • 2.28 Checking ONOS nodes - PASS (tick)
  • 2.29 Check number of topology elements - PASS (tick)
  • 2.30 Check whether the flow count is >= 350 - PASS (tick)
  • 2.31 Check whether all flow status are ADDED - PASS (tick)
  • 2.32 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.33 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.34 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.35 Stopping Mininet - PASS (tick)
  • 2.36 Copying karaf logs - PASS (tick)

Case 3: Cluster Restart test with single switch - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Set logging levels - PASS (tick)
  • 3.13 Set ONOS configurations - PASS (tick)
  • 3.14 Starting Mininet Topology - PASS (tick)
  • 3.15 Check whether the flow count is >= 15 - PASS (tick)
  • 3.16 Check whether all flow status are ADDED - PASS (tick)
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.21 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.25 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.26 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.27 Checking if ONOS CLI is ready - PASS (tick)
  • 3.28 Checking if ONOS CLI is ready - PASS (tick)
  • 3.29 Checking if ONOS CLI is ready - PASS (tick)
  • 3.30 Checking ONOS nodes - PASS (tick)
  • 3.31 Check number of topology elements - PASS (tick)
  • 3.32 Check whether the flow count is >= 15 - PASS (tick)
  • 3.33 Check whether all flow status are ADDED - PASS (tick)
  • 3.34 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.37 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.38 Stopping Mininet - PASS (tick)
  • 3.39 Copying karaf logs - PASS (tick)
  • No labels