Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 55 Next »

SRDynamic at 15 May 2021 23:58:03

SRDynamic

commit d9a9ca2c86956bec4defd819c1225a7db7c677cf (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Tue May 4 16:48:36 2021 +0200
Commit: pierventre [pier@opennetworking.org]
CommitDate: Fri May 14 09:19:24 2021 +0200

[AETHER-1265] Integrate Java profiler in TOST env

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spineand 1 nodes. - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is >= 116 - PASS (tick)
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS (tick)
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.21 Pushing new configuration - No Result (warning)
  • 1.22 Pushing new configuration - No Result (warning)
  • 1.23 Check whether the flow count is >= 140 - PASS (tick)
  • 1.24 Check whether all flow status are ADDED - PASS (tick)
  • 1.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.28 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE1 - PASS (tick)
  • 1.29 Stopping Mininet - PASS (tick)
  • 1.30 Copying karaf logs - PASS (tick)

Case 2: Bridging and Routing sanity test with 4x4 Leaf-spineand 1 nodes. - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Set logging levels - PASS (tick)
  • 2.13 Set ONOS configurations - PASS (tick)
  • 2.14 Starting Mininet Topology - PASS (tick)
  • 2.15 Check whether the flow count is >= 350 - PASS (tick)
  • 2.16 Check whether all flow status are ADDED - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - PASS (tick)
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.20 Pushing new configuration - No Result (warning)
  • 2.21 Pushing new configuration - No Result (warning)
  • 2.22 Check whether the flow count is >= 380 - PASS (tick)
  • 2.23 Check whether all flow status are ADDED - PASS (tick)
  • 2.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.27 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE2 - PASS (tick)
  • 2.28 Stopping Mininet - PASS (tick)
  • 2.29 Copying karaf logs - PASS (tick)

Case 3: Bridging and Routing sanity test with single switchand 1 nodes. - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Set logging levels - PASS (tick)
  • 3.13 Set ONOS configurations - PASS (tick)
  • 3.14 Starting Mininet Topology - PASS (tick)
  • 3.15 Check whether the flow count is >= 15 - PASS (tick)
  • 3.16 Check whether all flow status are ADDED - PASS (tick)
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.21 Pushing new configuration - No Result (warning)
  • 3.22 Pushing new configuration - No Result (warning)
  • 3.23 Check whether the flow count is >= 18 - PASS (tick)
  • 3.24 Check whether all flow status are ADDED - PASS (tick)
  • 3.25 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.28 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE3 - PASS (tick)
  • 3.29 Stopping Mininet - PASS (tick)
  • 3.30 Copying karaf logs - PASS (tick)

Case 4: Bridging and Routing sanity test with 2x2 Leaf-spineand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Set logging levels - PASS (tick)
  • 4.13 Set ONOS configurations - PASS (tick)
  • 4.14 Starting Mininet Topology - PASS (tick)
  • 4.15 Check whether the flow count is >= 116 - PASS (tick)
  • 4.16 Check whether all flow status are ADDED - PASS (tick)
  • 4.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - PASS (tick)
  • 4.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.20 Pushing new configuration - No Result (warning)
  • 4.21 Pushing new configuration - No Result (warning)
  • 4.22 Check whether the flow count is >= 140 - PASS (tick)
  • 4.23 Check whether all flow status are ADDED - PASS (tick)
  • 4.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.27 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE4 - PASS (tick)
  • 4.28 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 4.29 Check number of topology elements - PASS (tick)
  • 4.30 Removing host configuration - No Result (warning)
  • 4.31 Removing configuration - No Result (warning)
  • 4.32 Removing vlan configuration - No Result (warning)
  • 4.33 Stopping Mininet - PASS (tick)
  • 4.34 Copying karaf logs - PASS (tick)
    • Skipping the rest of this case. deleteXconnect() got an unexpected keyword argument 'vlanId'

Case 5: Bridging and Routing sanity test with 4x4 Leaf-spineand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Set logging levels - PASS (tick)
  • 5.13 Set ONOS configurations - PASS (tick)
  • 5.14 Starting Mininet Topology - PASS (tick)
  • 5.15 Check whether the flow count is >= 350 - PASS (tick)
  • 5.16 Check whether all flow status are ADDED - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.20 Pushing new configuration - No Result (warning)
  • 5.21 Pushing new configuration - No Result (warning)
  • 5.22 Check whether the flow count is >= 380 - PASS (tick)
  • 5.23 Check whether all flow status are ADDED - PASS (tick)
  • 5.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.27 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE5 - PASS (tick)
  • 5.28 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 5.29 Check number of topology elements - PASS (tick)
  • 5.30 Removing host configuration - No Result (warning)
  • 5.31 Removing configuration - No Result (warning)
  • 5.32 Removing vlan configuration - No Result (warning)
  • 5.33 Stopping Mininet - PASS (tick)
  • 5.34 Copying karaf logs - PASS (tick)
    • Skipping the rest of this case. deleteXconnect() got an unexpected keyword argument 'vlanId'

Case 6: Bridging and Routing sanity test with single switchand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Creating ONOS package - PASS (tick)
  • 6.5 Installing Atomix - PASS (tick)
  • 6.6 Installing ONOS package - PASS (tick)
  • 6.7 Set up ONOS secure SSH - PASS (tick)
  • 6.8 Checking ONOS service - PASS (tick)
  • 6.9 Starting ONOS CLI sessions - PASS (tick)
  • 6.10 Checking ONOS nodes - PASS (tick)
  • 6.11 Checking ONOS applications - PASS (tick)
  • 6.12 Set logging levels - PASS (tick)
  • 6.13 Set ONOS configurations - PASS (tick)
  • 6.14 Starting Mininet Topology - PASS (tick)
  • 6.15 Check whether the flow count is >= 15 - PASS (tick)
  • 6.16 Check whether all flow status are ADDED - PASS (tick)
  • 6.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.21 Pushing new configuration - No Result (warning)
  • 6.22 Pushing new configuration - No Result (warning)
  • 6.23 Check whether the flow count is >= 20 - PASS (tick)
  • 6.24 Check whether all flow status are ADDED - PASS (tick)
  • 6.25 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - PASS (tick)
  • 6.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - PASS (tick)
  • 6.28 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE6 - PASS (tick)
  • 6.29 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 6.30 Check number of topology elements - PASS (tick)
  • 6.31 Removing host configuration - No Result (warning)
  • 6.32 Removing configuration - No Result (warning)
  • 6.33 Removing vlan configuration - No Result (warning)
  • 6.34 Stopping Mininet - PASS (tick)
  • 6.35 Copying karaf logs - PASS (tick)
    • Skipping the rest of this case. deleteXconnect() got an unexpected keyword argument 'vlanId'
  • No labels