Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 13 Next »

SROnosFailure at 28 May 2021 23:19:15

SROnosFailure

commit db347377bec8bf6f71fb9828f4dc552731e562f7 (HEAD -] onos-2.5, origin/onos-2.5)
Author: Carmelo Cascone [carmelo@opennetworking.org]
AuthorDate: Wed May 26 19:30:30 2021 +0200
Commit: Carmelo Cascone [carmelo@opennetworking.org]
CommitDate: Thu May 27 19:53:15 2021 +0200

SDFAB-193 Add packet-out routing feature to fabric-v1model

Case 1: ONOS Failure test with 2x2 Leaf-spine - PASS

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS (tick)
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.21 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.22 Check number of topology elements - PASS (tick)
  • 1.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - PASS (tick)
  • 1.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.26 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.27 Checking if ONOS CLI is ready - PASS (tick)
  • 1.28 Checking ONOS nodes - PASS (tick)
  • 1.29 Check number of topology elements - PASS (tick)
  • 1.30 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.31 Check whether all flow status are ADDED - PASS (tick)
  • 1.32 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - PASS (tick)
  • 1.33 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS (tick)
  • 1.34 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS (tick)
  • 1.35 Stopping Mininet - PASS (tick)
  • 1.36 Copying karaf logs - PASS (tick)

Case 2: ONOS Failure test with 4x4 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Set logging levels - PASS (tick)
  • 2.13 Set ONOS configurations - PASS (tick)
  • 2.14 Starting Mininet Topology - PASS (tick)
  • 2.15 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.16 Check whether all flow status are ADDED - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.20 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 2.21 Check number of topology elements - PASS (tick)
  • 2.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.25 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 2.26 Checking if ONOS CLI is ready - PASS (tick)
  • 2.27 Checking ONOS nodes - PASS (tick)
  • 2.28 Check number of topology elements - PASS (tick)
  • 2.29 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.30 Check whether all flow status are ADDED - PASS (tick)
  • 2.31 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.32 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - PASS (tick)
  • 2.33 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - PASS (tick)
  • 2.34 Stopping Mininet - PASS (tick)
  • 2.35 Copying karaf logs - PASS (tick)

Case 3: ONOS Failure test with single switch - PASS

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Set logging levels - PASS (tick)
  • 3.13 Set ONOS configurations - PASS (tick)
  • 3.14 Starting Mininet Topology - PASS (tick)
  • 3.15 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.16 Check whether all flow status are ADDED - PASS (tick)
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - PASS (tick)
  • 3.21 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 3.22 Check number of topology elements - PASS (tick)
  • 3.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 3.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 3.26 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - PASS (tick)
  • 3.27 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 3.28 Checking if ONOS CLI is ready - PASS (tick)
  • 3.29 Checking ONOS nodes - PASS (tick)
  • 3.30 Check number of topology elements - PASS (tick)
  • 3.31 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.32 Check whether all flow status are ADDED - PASS (tick)
  • 3.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Recovery - PASS (tick)
  • 3.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Recovery - PASS (tick)
  • 3.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Recovery - PASS (tick)
  • 3.36 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Recovery - PASS (tick)
  • 3.37 Stopping Mininet - PASS (tick)
  • 3.38 Copying karaf logs - PASS (tick)