Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
SRRouting at 22 May 2021 12:09:15
commit d14355c0712d9392fe76b503f7de19b83ab941ac (HEAD -] onos-2.2, origin/onos-2.2)
Author: Andrea Campanella [andrea@opennetworking.org]
AuthorDate: Mon May 3 15:59:19 2021 +0200
Commit: Andrea Campanella [andrea@opennetworking.org]
CommitDate: Wed May 19 11:03:52 2021 +0000
[VOL-4055][ONOS-8138] Adding annotations to meter to allow passing of associated information
Case 1: Ping between all ipv4 hosts in the topology - PASS
- 1.1 Constructing test variables - PASS
- 1.2 Apply cell to environment - PASS
- 1.3 Uninstalling Atomix - PASS
- 1.4 Uninstalling ONOS package - PASS
- 1.5 Creating ONOS package - PASS
- 1.6 Installing Atomix - PASS
- 1.7 Installing ONOS package - PASS
- 1.8 Set up ONOS secure SSH - PASS
- 1.9 Checking ONOS service - PASS
- 1.10 Starting ONOS CLI sessions - PASS
- 1.11 Checking ONOS nodes - PASS
- 1.12 Checking ONOS applications - PASS
- 1.13 Set logging levels - PASS
- 1.14 Set ONOS configurations - PASS
- 1.15 Starting Mininet Topology - PASS
- 1.16 Check number of topology elements - PASS
- 1.17 Verify reachability of connected internal IPv4 hosts - PASS
- 1.18 Verify host IP address assignment in ONOS - PASS
- 1.19 Verify IP address assignment from hosts - PASS
- 1.20 Verify reachability of connected internal IPv4 hosts - PASS
- 1.21 Stopping Mininet - PASS
Case 2: Ping between all ipv6 hosts in the topology - PASS
- 2.1 Apply cell to environment - PASS
- 2.2 Uninstalling Atomix - PASS
- 2.3 Uninstalling ONOS package - PASS
- 2.4 Installing Atomix - PASS
- 2.5 Installing ONOS package - PASS
- 2.6 Set up ONOS secure SSH - PASS
- 2.7 Checking ONOS service - PASS
- 2.8 Starting ONOS CLI sessions - PASS
- 2.9 Checking ONOS nodes - PASS
- 2.10 Checking ONOS applications - PASS
- 2.11 Set logging levels - PASS
- 2.12 Set ONOS configurations - PASS
- 2.13 Starting Mininet Topology - PASS
- 2.14 Check number of topology elements - PASS
- 2.15 Verify reachability of connected internal IPv6 hosts - PASS
- 2.16 Verify host IP address assignment in ONOS - PASS
- 2.17 Verify IP address assignment from hosts - PASS
- 2.18 Verify reachability of connected internal IPv6 hosts - PASS
- 2.19 Stopping Mininet - PASS
Case 3: Ping between all ipv4 and ipv6 hosts in the topology - PASS
- 3.1 Apply cell to environment - PASS
- 3.2 Uninstalling Atomix - PASS
- 3.3 Uninstalling ONOS package - PASS
- 3.4 Installing Atomix - PASS
- 3.5 Installing ONOS package - PASS
- 3.6 Set up ONOS secure SSH - PASS
- 3.7 Checking ONOS service - PASS
- 3.8 Starting ONOS CLI sessions - PASS
- 3.9 Checking ONOS nodes - PASS
- 3.10 Checking ONOS applications - PASS
- 3.11 Set logging levels - PASS
- 3.12 Set ONOS configurations - PASS
- 3.13 Starting Mininet Topology - PASS
- 3.14 Check number of topology elements - PASS
- 3.15 Verify reachability of connected internal IPv4 hosts - PASS
- 3.16 Verify reachability of connected internal IPv6 hosts - PASS
- 3.17 Verify host IP address assignment in ONOS - PASS
- 3.18 Verify IP address assignment from hosts - PASS
- 3.19 Verify reachability of connected internal IPv4 hosts - PASS
- 3.20 Verify reachability of connected internal IPv6 hosts - PASS
- 3.21 Stopping Mininet - PASS
Case 4: Ping between all ipv4 hosts in the topology and check connectivity to external ipv4 hosts - FAIL
- 4.1 Apply cell to environment - PASS
- 4.2 Uninstalling Atomix - PASS
- 4.3 Uninstalling ONOS package - PASS
- 4.4 Installing Atomix - PASS
- 4.5 Installing ONOS package - PASS
- 4.6 Set up ONOS secure SSH - PASS
- 4.7 Checking ONOS service - PASS
- 4.8 Starting ONOS CLI sessions - PASS
- 4.9 Checking ONOS nodes - PASS
- 4.10 Checking ONOS applications - PASS
- 4.11 Set logging levels - PASS
- 4.12 Set ONOS configurations - PASS
- 4.13 Starting Mininet Topology - PASS
- 4.14 Check number of topology elements - PASS
- 4.15 Verify reachability of connected internal IPv4 hosts - FAIL
- Verify reachability of connected internal IPv4 hosts: Fail
- 4.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 5: Ping between all ipv6 hosts in the topology and check connectivity to external ipv6 hosts - PASS
- 5.1 Apply cell to environment - PASS
- 5.2 Uninstalling Atomix - PASS
- 5.3 Uninstalling ONOS package - PASS
- 5.4 Installing Atomix - PASS
- 5.5 Installing ONOS package - PASS
- 5.6 Set up ONOS secure SSH - PASS
- 5.7 Checking ONOS service - PASS
- 5.8 Starting ONOS CLI sessions - PASS
- 5.9 Checking ONOS nodes - PASS
- 5.10 Checking ONOS applications - PASS
- 5.11 Set logging levels - PASS
- 5.12 Set ONOS configurations - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check number of topology elements - PASS
- 5.15 Verify reachability of connected internal IPv6 hosts - PASS
- 5.16 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 5.17 Verify host IP address assignment in ONOS - PASS
- 5.18 Verify IP address assignment from hosts - PASS
- 5.19 Verify reachability of connected internal IPv6 hosts - PASS
- 5.20 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 5.21 Stopping Mininet - PASS
Case 6: Ping between all ipv4 and ipv6 hosts in the topology and check connectivity to external hosts - FAIL
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Check number of topology elements - PASS
- 6.15 Verify reachability of connected internal IPv4 hosts - FAIL
- Verify reachability of connected internal IPv4 hosts: Fail
- 6.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 7: Ping between from ipv4 hosts to external host configured with route-add command - PASS
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Check number of topology elements - PASS
- 7.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 7.16 Verify host IP address assignment in ONOS - PASS
- 7.17 Verify IP address assignment from hosts - PASS
- 7.18 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 7.19 Stopping Mininet - PASS
Case 8: Ping between from ipv6 hosts to external host configured with route-add command - PASS
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Set logging levels - PASS
- 8.12 Set ONOS configurations - PASS
- 8.13 Starting Mininet Topology - PASS
- 8.14 Check number of topology elements - PASS
- 8.15 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 8.16 Verify host IP address assignment in ONOS - PASS
- 8.17 Verify IP address assignment from hosts - PASS
- 8.18 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 8.19 Stopping Mininet - PASS
Case 9: Ping between from ipv4 and ipv6 hosts to external host configured with route-add command - PASS
- 9.1 Apply cell to environment - PASS
- 9.2 Uninstalling Atomix - PASS
- 9.3 Uninstalling ONOS package - PASS
- 9.4 Installing Atomix - PASS
- 9.5 Installing ONOS package - PASS
- 9.6 Set up ONOS secure SSH - PASS
- 9.7 Checking ONOS service - PASS
- 9.8 Starting ONOS CLI sessions - PASS
- 9.9 Checking ONOS nodes - PASS
- 9.10 Checking ONOS applications - PASS
- 9.11 Set logging levels - PASS
- 9.12 Set ONOS configurations - PASS
- 9.13 Starting Mininet Topology - PASS
- 9.14 Check number of topology elements - PASS
- 9.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 9.16 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 9.17 Verify host IP address assignment in ONOS - PASS
- 9.18 Verify IP address assignment from hosts - PASS
- 9.19 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 9.20 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 9.21 Stopping Mininet - PASS
Case 101: Test link failures with IPv4 hosts - FAIL
- 101.1 Apply cell to environment - PASS
- 101.2 Uninstalling Atomix - PASS
- 101.3 Uninstalling ONOS package - PASS
- 101.4 Installing Atomix - PASS
- 101.5 Installing ONOS package - PASS
- 101.6 Set up ONOS secure SSH - PASS
- 101.7 Checking ONOS service - PASS
- 101.8 Starting ONOS CLI sessions - PASS
- 101.9 Checking ONOS nodes - PASS
- 101.10 Checking ONOS applications - PASS
- 101.11 Set logging levels - PASS
- 101.12 Set ONOS configurations - PASS
- 101.13 Starting Mininet Topology - PASS
- 101.14 Check number of topology elements - PASS
- 101.15 Verify reachability of connected internal IPv4 hosts - PASS
- 101.16 Verify host IP address assignment in ONOS - PASS
- 101.17 Verify IP address assignment from hosts - PASS
- 101.18 Verify reachability of connected internal IPv4 hosts - PASS
- 101.19 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - FAIL
- Link batch down failed
- 101.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 101.21 Verify reachability of connected internal IPv4 hosts - PASS
- 101.22 Verify host IP address assignment in ONOS - PASS
- 101.23 Verify IP address assignment from hosts - PASS
- 101.24 Verify reachability of connected internal IPv4 hosts - PASS
- 101.25 Restoring a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS
- 101.26 Check number of topology elements - PASS
- 101.27 Verify reachability of connected internal IPv4 hosts - PASS
- 101.28 Verify host IP address assignment in ONOS - PASS
- 101.29 Verify IP address assignment from hosts - PASS
- 101.30 Verify reachability of connected internal IPv4 hosts - PASS
- 101.31 Killing a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - FAIL
- Link batch down failed
- 101.32 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 101.33 Verify reachability of connected internal IPv4 hosts - PASS
- 101.34 Verify host IP address assignment in ONOS - PASS
- 101.35 Verify IP address assignment from hosts - PASS
- 101.36 Verify reachability of connected internal IPv4 hosts - PASS
- 101.37 Restoring a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS
- 101.38 Check number of topology elements - PASS
- 101.39 Verify reachability of connected internal IPv4 hosts - PASS
- 101.40 Verify host IP address assignment in ONOS - PASS
- 101.41 Verify IP address assignment from hosts - PASS
- 101.42 Verify reachability of connected internal IPv4 hosts - PASS
- 101.43 Stopping Mininet - PASS
Case 102: Test link failures with IPv6 hosts - FAIL
- 102.1 Apply cell to environment - PASS
- 102.2 Uninstalling Atomix - PASS
- 102.3 Uninstalling ONOS package - PASS
- 102.4 Installing Atomix - PASS
- 102.5 Installing ONOS package - PASS
- 102.6 Set up ONOS secure SSH - PASS
- 102.7 Checking ONOS service - PASS
- 102.8 Starting ONOS CLI sessions - PASS
- 102.9 Checking ONOS nodes - PASS
- 102.10 Checking ONOS applications - PASS
- 102.11 Set logging levels - PASS
- 102.12 Set ONOS configurations - PASS
- 102.13 Starting Mininet Topology - PASS
- 102.14 Check number of topology elements - PASS
- 102.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 102.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 103: Test link failures with IPv4 and IPv6 hosts - FAIL
- 103.1 Apply cell to environment - PASS
- 103.2 Uninstalling Atomix - PASS
- 103.3 Uninstalling ONOS package - PASS
- 103.4 Installing Atomix - PASS
- 103.5 Installing ONOS package - PASS
- 103.6 Set up ONOS secure SSH - PASS
- 103.7 Checking ONOS service - PASS
- 103.8 Starting ONOS CLI sessions - PASS
- 103.9 Checking ONOS nodes - PASS
- 103.10 Checking ONOS applications - PASS
- 103.11 Set logging levels - PASS
- 103.12 Set ONOS configurations - PASS
- 103.13 Starting Mininet Topology - PASS
- 103.14 Check number of topology elements - PASS
- 103.15 Verify reachability of connected internal IPv4 hosts - PASS
- 103.16 Verify reachability of connected internal IPv6 hosts - PASS
- 103.17 Verify host IP address assignment in ONOS - PASS
- 103.18 Verify IP address assignment from hosts - PASS
- 103.19 Verify reachability of connected internal IPv4 hosts - PASS
- 103.20 Verify reachability of connected internal IPv6 hosts - PASS
- 103.21 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - FAIL
- Link batch down failed
- 103.22 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 103.23 Verify reachability of connected internal IPv4 hosts - PASS
- 103.24 Verify reachability of connected internal IPv6 hosts - PASS
- 103.25 Verify host IP address assignment in ONOS - PASS
- 103.26 Verify IP address assignment from hosts - PASS
- 103.27 Verify reachability of connected internal IPv4 hosts - PASS
- 103.28 Verify reachability of connected internal IPv6 hosts - PASS
- 103.29 Restoring a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS
- 103.30 Check number of topology elements - PASS
- 103.31 Verify reachability of connected internal IPv4 hosts - PASS
- 103.32 Verify reachability of connected internal IPv6 hosts - PASS
- 103.33 Verify host IP address assignment in ONOS - PASS
- 103.34 Verify IP address assignment from hosts - PASS
- 103.35 Verify reachability of connected internal IPv4 hosts - PASS
- 103.36 Verify reachability of connected internal IPv6 hosts - PASS
- 103.37 Killing a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - FAIL
- Link batch down failed
- 103.38 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 103.39 Verify reachability of connected internal IPv4 hosts - PASS
- 103.40 Verify reachability of connected internal IPv6 hosts - PASS
- 103.41 Verify host IP address assignment in ONOS - PASS
- 103.42 Verify IP address assignment from hosts - PASS
- 103.43 Verify reachability of connected internal IPv4 hosts - PASS
- 103.44 Verify reachability of connected internal IPv6 hosts - PASS
- 103.45 Restoring a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS
- 103.46 Check number of topology elements - PASS
- 103.47 Verify reachability of connected internal IPv4 hosts - PASS
- 103.48 Verify reachability of connected internal IPv6 hosts - PASS
- 103.49 Verify host IP address assignment in ONOS - PASS
- 103.50 Verify IP address assignment from hosts - PASS
- 103.51 Verify reachability of connected internal IPv4 hosts - PASS
- 103.52 Verify reachability of connected internal IPv6 hosts - PASS
- 103.53 Stopping Mininet - PASS
Case 104: Test link failures with IPv4 hosts including external hosts - FAIL
- 104.1 Apply cell to environment - PASS
- 104.2 Uninstalling Atomix - PASS
- 104.3 Uninstalling ONOS package - PASS
- 104.4 Installing Atomix - PASS
- 104.5 Installing ONOS package - PASS
- 104.6 Set up ONOS secure SSH - PASS
- 104.7 Checking ONOS service - PASS
- 104.8 Starting ONOS CLI sessions - PASS
- 104.9 Checking ONOS nodes - PASS
- 104.10 Checking ONOS applications - PASS
- 104.11 Set logging levels - PASS
- 104.12 Set ONOS configurations - PASS
- 104.13 Starting Mininet Topology - PASS
- 104.14 Check number of topology elements - PASS
- 104.15 Verify reachability of connected internal IPv4 hosts - PASS
- 104.16 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.17 Verify host IP address assignment in ONOS - PASS
- 104.18 Verify IP address assignment from hosts - PASS
- 104.19 Verify reachability of connected internal IPv4 hosts - PASS
- 104.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.21 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - FAIL
- Link batch down failed
- 104.22 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 104.23 Verify reachability of connected internal IPv4 hosts - PASS
- 104.24 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.25 Verify host IP address assignment in ONOS - PASS
- 104.26 Verify IP address assignment from hosts - PASS
- 104.27 Verify reachability of connected internal IPv4 hosts - PASS
- 104.28 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.29 Restoring a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS
- 104.30 Check number of topology elements - PASS
- 104.31 Verify reachability of connected internal IPv4 hosts - PASS
- 104.32 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.33 Verify host IP address assignment in ONOS - PASS
- 104.34 Verify IP address assignment from hosts - PASS
- 104.35 Verify reachability of connected internal IPv4 hosts - PASS
- 104.36 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.37 Killing a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - FAIL
- Link batch down failed
- 104.38 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 104.39 Verify reachability of connected internal IPv4 hosts - PASS
- 104.40 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.41 Verify host IP address assignment in ONOS - PASS
- 104.42 Verify IP address assignment from hosts - PASS
- 104.43 Verify reachability of connected internal IPv4 hosts - PASS
- 104.44 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.45 Restoring a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS
- 104.46 Check number of topology elements - PASS
- 104.47 Verify reachability of connected internal IPv4 hosts - PASS
- 104.48 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.49 Verify host IP address assignment in ONOS - PASS
- 104.50 Verify IP address assignment from hosts - PASS
- 104.51 Verify reachability of connected internal IPv4 hosts - PASS
- 104.52 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 104.53 Stopping Mininet - PASS
Case 105: Test link failures with IPv6 hosts including external hosts - FAIL
- 105.1 Apply cell to environment - PASS
- 105.2 Uninstalling Atomix - PASS
- 105.3 Uninstalling ONOS package - PASS
- 105.4 Installing Atomix - PASS
- 105.5 Installing ONOS package - PASS
- 105.6 Set up ONOS secure SSH - PASS
- 105.7 Checking ONOS service - PASS
- 105.8 Starting ONOS CLI sessions - PASS
- 105.9 Checking ONOS nodes - PASS
- 105.10 Checking ONOS applications - PASS
- 105.11 Set logging levels - PASS
- 105.12 Set ONOS configurations - PASS
- 105.13 Starting Mininet Topology - PASS
- 105.14 Check number of topology elements - PASS
- 105.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 105.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 106: Test link failures with IPv4 and IPv6 hosts including external hosts - FAIL
- 106.1 Apply cell to environment - PASS
- 106.2 Uninstalling Atomix - PASS
- 106.3 Uninstalling ONOS package - PASS
- 106.4 Installing Atomix - PASS
- 106.5 Installing ONOS package - PASS
- 106.6 Set up ONOS secure SSH - PASS
- 106.7 Checking ONOS service - PASS
- 106.8 Starting ONOS CLI sessions - PASS
- 106.9 Checking ONOS nodes - PASS
- 106.10 Checking ONOS applications - PASS
- 106.11 Set logging levels - PASS
- 106.12 Set ONOS configurations - PASS
- 106.13 Starting Mininet Topology - PASS
- 106.14 Check number of topology elements - PASS
- 106.15 Verify reachability of connected internal IPv4 hosts - PASS
- 106.16 Verify reachability of connected internal IPv6 hosts - PASS
- 106.17 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - FAIL
- Verify reachability from connected internal IPv4 hosts to external IPv4 hosts: Fail
- 106.18 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 107: Test link failures with IPv4 hosts including external hosts configured with route-add command - FAIL
- 107.1 Apply cell to environment - PASS
- 107.2 Uninstalling Atomix - PASS
- 107.3 Uninstalling ONOS package - PASS
- 107.4 Installing Atomix - PASS
- 107.5 Installing ONOS package - PASS
- 107.6 Set up ONOS secure SSH - PASS
- 107.7 Checking ONOS service - PASS
- 107.8 Starting ONOS CLI sessions - PASS
- 107.9 Checking ONOS nodes - PASS
- 107.10 Checking ONOS applications - PASS
- 107.11 Set logging levels - PASS
- 107.12 Set ONOS configurations - PASS
- 107.13 Starting Mininet Topology - PASS
- 107.14 Check number of topology elements - PASS
- 107.15 Verify reachability of connected internal IPv4 hosts - FAIL
- Verify reachability of connected internal IPv4 hosts: Fail
- 107.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 108: Test link failures with IPv6 hosts including external hosts configured with route-add command - FAIL
- 108.1 Apply cell to environment - PASS
- 108.2 Uninstalling Atomix - PASS
- 108.3 Uninstalling ONOS package - PASS
- 108.4 Installing Atomix - PASS
- 108.5 Installing ONOS package - PASS
- 108.6 Set up ONOS secure SSH - PASS
- 108.7 Checking ONOS service - PASS
- 108.8 Starting ONOS CLI sessions - PASS
- 108.9 Checking ONOS nodes - PASS
- 108.10 Checking ONOS applications - PASS
- 108.11 Set logging levels - PASS
- 108.12 Set ONOS configurations - PASS
- 108.13 Starting Mininet Topology - PASS
- 108.14 Check number of topology elements - PASS
- 108.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 108.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 109: Test link failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL
- 109.1 Apply cell to environment - PASS
- 109.2 Uninstalling Atomix - PASS
- 109.3 Uninstalling ONOS package - PASS
- 109.4 Installing Atomix - PASS
- 109.5 Installing ONOS package - PASS
- 109.6 Set up ONOS secure SSH - PASS
- 109.7 Checking ONOS service - PASS
- 109.8 Starting ONOS CLI sessions - PASS
- 109.9 Checking ONOS nodes - PASS
- 109.10 Checking ONOS applications - PASS
- 109.11 Set logging levels - PASS
- 109.12 Set ONOS configurations - PASS
- 109.13 Starting Mininet Topology - PASS
- 109.14 Check number of topology elements - PASS
- 109.15 Verify reachability of connected internal IPv4 hosts - PASS
- 109.16 Verify reachability of connected internal IPv6 hosts - PASS
- 109.17 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.18 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.19 Verify host IP address assignment in ONOS - PASS
- 109.20 Verify IP address assignment from hosts - PASS
- 109.21 Verify reachability of connected internal IPv4 hosts - PASS
- 109.22 Verify reachability of connected internal IPv6 hosts - PASS
- 109.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.24 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.25 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - FAIL
- Link batch down failed
- 109.26 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 109.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.28 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.29 Verify host IP address assignment in ONOS - PASS
- 109.30 Verify IP address assignment from hosts - PASS
- 109.31 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.32 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.33 Restoring a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS
- 109.34 Check number of topology elements - PASS
- 109.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.36 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.37 Verify host IP address assignment in ONOS - PASS
- 109.38 Verify IP address assignment from hosts - PASS
- 109.39 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.40 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.41 Killing a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - FAIL
- Link batch down failed
- 109.42 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 2 SCCs (1 expected)
- 109.43 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.44 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.45 Verify host IP address assignment in ONOS - PASS
- 109.46 Verify IP address assignment from hosts - PASS
- 109.47 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.48 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.49 Restoring a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS
- 109.50 Check number of topology elements - PASS
- 109.51 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.52 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.53 Verify host IP address assignment in ONOS - PASS
- 109.54 Verify IP address assignment from hosts - PASS
- 109.55 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 109.56 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 109.57 Stopping Mininet - PASS
Case 201: Test switch failures with IPv4 hosts - FAIL
- 201.1 Apply cell to environment - PASS
- 201.2 Uninstalling Atomix - PASS
- 201.3 Uninstalling ONOS package - PASS
- 201.4 Installing Atomix - PASS
- 201.5 Installing ONOS package - PASS
- 201.6 Set up ONOS secure SSH - PASS
- 201.7 Checking ONOS service - PASS
- 201.8 Starting ONOS CLI sessions - PASS
- 201.9 Checking ONOS nodes - PASS
- 201.10 Checking ONOS applications - PASS
- 201.11 Set logging levels - PASS
- 201.12 Set ONOS configurations - PASS
- 201.13 Starting Mininet Topology - PASS
- 201.14 Check number of topology elements - PASS
- 201.15 Verify reachability of connected internal IPv4 hosts - PASS
- 201.16 Verify host IP address assignment in ONOS - PASS
- 201.17 Verify IP address assignment from hosts - PASS
- 201.18 Verify reachability of connected internal IPv4 hosts - PASS
- 201.19 Kill ['spine101'] - PASS
- 201.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 201.21 Verify reachability of connected internal IPv4 hosts - PASS
- 201.22 Verify host IP address assignment in ONOS - PASS
- 201.23 Verify IP address assignment from hosts - PASS
- 201.24 Verify reachability of connected internal IPv4 hosts - PASS
- 201.25 Recovering ['spine101'] - PASS
- 201.26 Check number of topology elements - PASS
- 201.27 Verify reachability of connected internal IPv4 hosts - PASS
- 201.28 Verify host IP address assignment in ONOS - PASS
- 201.29 Verify IP address assignment from hosts - PASS
- 201.30 Verify reachability of connected internal IPv4 hosts - PASS
- 201.31 Kill ['spine102'] - PASS
- 201.32 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 201.33 Verify reachability of connected internal IPv4 hosts - PASS
- 201.34 Verify host IP address assignment in ONOS - PASS
- 201.35 Verify IP address assignment from hosts - PASS
- 201.36 Verify reachability of connected internal IPv4 hosts - PASS
- 201.37 Recovering ['spine102'] - PASS
- 201.38 Check number of topology elements - PASS
- 201.39 Verify reachability of connected internal IPv4 hosts - PASS
- 201.40 Verify host IP address assignment in ONOS - PASS
- 201.41 Verify IP address assignment from hosts - PASS
- 201.42 Verify reachability of connected internal IPv4 hosts - PASS
- 201.43 Stopping Mininet - PASS
Case 202: Test switch failures with IPv6 hosts - FAIL
- 202.1 Apply cell to environment - PASS
- 202.2 Uninstalling Atomix - PASS
- 202.3 Uninstalling ONOS package - PASS
- 202.4 Installing Atomix - PASS
- 202.5 Installing ONOS package - PASS
- 202.6 Set up ONOS secure SSH - PASS
- 202.7 Checking ONOS service - PASS
- 202.8 Starting ONOS CLI sessions - PASS
- 202.9 Checking ONOS nodes - PASS
- 202.10 Checking ONOS applications - PASS
- 202.11 Set logging levels - PASS
- 202.12 Set ONOS configurations - PASS
- 202.13 Starting Mininet Topology - PASS
- 202.14 Check number of topology elements - PASS
- 202.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 202.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 203: Test switch failures with IPv4 and IPv6 hosts - FAIL
- 203.1 Apply cell to environment - PASS
- 203.2 Uninstalling Atomix - PASS
- 203.3 Uninstalling ONOS package - PASS
- 203.4 Installing Atomix - PASS
- 203.5 Installing ONOS package - PASS
- 203.6 Set up ONOS secure SSH - PASS
- 203.7 Checking ONOS service - PASS
- 203.8 Starting ONOS CLI sessions - PASS
- 203.9 Checking ONOS nodes - PASS
- 203.10 Checking ONOS applications - PASS
- 203.11 Set logging levels - PASS
- 203.12 Set ONOS configurations - PASS
- 203.13 Starting Mininet Topology - PASS
- 203.14 Check number of topology elements - PASS
- 203.15 Verify reachability of connected internal IPv4 hosts - PASS
- 203.16 Verify reachability of connected internal IPv6 hosts - PASS
- 203.17 Verify host IP address assignment in ONOS - PASS
- 203.18 Verify IP address assignment from hosts - PASS
- 203.19 Verify reachability of connected internal IPv4 hosts - PASS
- 203.20 Verify reachability of connected internal IPv6 hosts - PASS
- 203.21 Kill ['spine101'] - PASS
- 203.22 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 203.23 Verify reachability of connected internal IPv4 hosts - PASS
- 203.24 Verify reachability of connected internal IPv6 hosts - PASS
- 203.25 Verify host IP address assignment in ONOS - PASS
- 203.26 Verify IP address assignment from hosts - PASS
- 203.27 Verify reachability of connected internal IPv4 hosts - PASS
- 203.28 Verify reachability of connected internal IPv6 hosts - PASS
- 203.29 Recovering ['spine101'] - PASS
- 203.30 Check number of topology elements - PASS
- 203.31 Verify reachability of connected internal IPv4 hosts - PASS
- 203.32 Verify reachability of connected internal IPv6 hosts - PASS
- 203.33 Verify host IP address assignment in ONOS - PASS
- 203.34 Verify IP address assignment from hosts - PASS
- 203.35 Verify reachability of connected internal IPv4 hosts - PASS
- 203.36 Verify reachability of connected internal IPv6 hosts - PASS
- 203.37 Kill ['spine102'] - PASS
- 203.38 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 203.39 Verify reachability of connected internal IPv4 hosts - PASS
- 203.40 Verify reachability of connected internal IPv6 hosts - PASS
- 203.41 Verify host IP address assignment in ONOS - PASS
- 203.42 Verify IP address assignment from hosts - PASS
- 203.43 Verify reachability of connected internal IPv4 hosts - PASS
- 203.44 Verify reachability of connected internal IPv6 hosts - PASS
- 203.45 Recovering ['spine102'] - PASS
- 203.46 Check number of topology elements - PASS
- 203.47 Verify reachability of connected internal IPv4 hosts - PASS
- 203.48 Verify reachability of connected internal IPv6 hosts - PASS
- 203.49 Verify host IP address assignment in ONOS - PASS
- 203.50 Verify IP address assignment from hosts - PASS
- 203.51 Verify reachability of connected internal IPv4 hosts - PASS
- 203.52 Verify reachability of connected internal IPv6 hosts - PASS
- 203.53 Stopping Mininet - PASS
Case 204: Test switch failures with IPv4 hosts including external hosts - FAIL
- 204.1 Apply cell to environment - PASS
- 204.2 Uninstalling Atomix - PASS
- 204.3 Uninstalling ONOS package - PASS
- 204.4 Installing Atomix - PASS
- 204.5 Installing ONOS package - PASS
- 204.6 Set up ONOS secure SSH - PASS
- 204.7 Checking ONOS service - PASS
- 204.8 Starting ONOS CLI sessions - PASS
- 204.9 Checking ONOS nodes - PASS
- 204.10 Checking ONOS applications - PASS
- 204.11 Set logging levels - PASS
- 204.12 Set ONOS configurations - PASS
- 204.13 Starting Mininet Topology - PASS
- 204.14 Check number of topology elements - PASS
- 204.15 Verify reachability of connected internal IPv4 hosts - PASS
- 204.16 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.17 Verify host IP address assignment in ONOS - PASS
- 204.18 Verify IP address assignment from hosts - PASS
- 204.19 Verify reachability of connected internal IPv4 hosts - PASS
- 204.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.21 Kill ['spine101'] - PASS
- 204.22 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 204.23 Verify reachability of connected internal IPv4 hosts - PASS
- 204.24 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.25 Verify host IP address assignment in ONOS - PASS
- 204.26 Verify IP address assignment from hosts - PASS
- 204.27 Verify reachability of connected internal IPv4 hosts - PASS
- 204.28 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.29 Recovering ['spine101'] - PASS
- 204.30 Check number of topology elements - PASS
- 204.31 Verify reachability of connected internal IPv4 hosts - PASS
- 204.32 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.33 Verify host IP address assignment in ONOS - PASS
- 204.34 Verify IP address assignment from hosts - PASS
- 204.35 Verify reachability of connected internal IPv4 hosts - PASS
- 204.36 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.37 Kill ['spine102'] - PASS
- 204.38 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 204.39 Verify reachability of connected internal IPv4 hosts - PASS
- 204.40 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.41 Verify host IP address assignment in ONOS - PASS
- 204.42 Verify IP address assignment from hosts - PASS
- 204.43 Verify reachability of connected internal IPv4 hosts - PASS
- 204.44 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.45 Recovering ['spine102'] - PASS
- 204.46 Check number of topology elements - PASS
- 204.47 Verify reachability of connected internal IPv4 hosts - PASS
- 204.48 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.49 Verify host IP address assignment in ONOS - PASS
- 204.50 Verify IP address assignment from hosts - PASS
- 204.51 Verify reachability of connected internal IPv4 hosts - PASS
- 204.52 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.53 Stopping Mininet - PASS
Case 205: Test switch failures with IPv6 hosts including external hosts - FAIL
- 205.1 Apply cell to environment - PASS
- 205.2 Uninstalling Atomix - PASS
- 205.3 Uninstalling ONOS package - PASS
- 205.4 Installing Atomix - PASS
- 205.5 Installing ONOS package - PASS
- 205.6 Set up ONOS secure SSH - PASS
- 205.7 Checking ONOS service - PASS
- 205.8 Starting ONOS CLI sessions - PASS
- 205.9 Checking ONOS nodes - PASS
- 205.10 Checking ONOS applications - PASS
- 205.11 Set logging levels - PASS
- 205.12 Set ONOS configurations - PASS
- 205.13 Starting Mininet Topology - PASS
- 205.14 Check number of topology elements - PASS
- 205.15 Verify reachability of connected internal IPv6 hosts - PASS
- 205.16 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.17 Verify host IP address assignment in ONOS - PASS
- 205.18 Verify IP address assignment from hosts - PASS
- 205.19 Verify reachability of connected internal IPv6 hosts - PASS
- 205.20 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.21 Kill ['spine101'] - PASS
- 205.22 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 205.23 Verify reachability of connected internal IPv6 hosts - PASS
- 205.24 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.25 Verify host IP address assignment in ONOS - PASS
- 205.26 Verify IP address assignment from hosts - PASS
- 205.27 Verify reachability of connected internal IPv6 hosts - PASS
- 205.28 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.29 Recovering ['spine101'] - PASS
- 205.30 Check number of topology elements - PASS
- 205.31 Verify reachability of connected internal IPv6 hosts - PASS
- 205.32 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.33 Verify host IP address assignment in ONOS - PASS
- 205.34 Verify IP address assignment from hosts - PASS
- 205.35 Verify reachability of connected internal IPv6 hosts - PASS
- 205.36 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.37 Kill ['spine102'] - PASS
- 205.38 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 205.39 Verify reachability of connected internal IPv6 hosts - PASS
- 205.40 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.41 Verify host IP address assignment in ONOS - PASS
- 205.42 Verify IP address assignment from hosts - PASS
- 205.43 Verify reachability of connected internal IPv6 hosts - PASS
- 205.44 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.45 Recovering ['spine102'] - PASS
- 205.46 Check number of topology elements - PASS
- 205.47 Verify reachability of connected internal IPv6 hosts - PASS
- 205.48 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.49 Verify host IP address assignment in ONOS - PASS
- 205.50 Verify IP address assignment from hosts - PASS
- 205.51 Verify reachability of connected internal IPv6 hosts - PASS
- 205.52 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 205.53 Stopping Mininet - PASS
Case 206: Test switch failures with IPv4 and IPv6 hosts including external hosts - FAIL
- 206.1 Apply cell to environment - PASS
- 206.2 Uninstalling Atomix - PASS
- 206.3 Uninstalling ONOS package - PASS
- 206.4 Installing Atomix - PASS
- 206.5 Installing ONOS package - PASS
- 206.6 Set up ONOS secure SSH - PASS
- 206.7 Checking ONOS service - PASS
- 206.8 Starting ONOS CLI sessions - PASS
- 206.9 Checking ONOS nodes - PASS
- 206.10 Checking ONOS applications - PASS
- 206.11 Set logging levels - PASS
- 206.12 Set ONOS configurations - PASS
- 206.13 Starting Mininet Topology - PASS
- 206.14 Check number of topology elements - PASS
- 206.15 Verify reachability of connected internal IPv4 hosts - PASS
- 206.16 Verify reachability of connected internal IPv6 hosts - PASS
- 206.17 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.18 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.19 Verify host IP address assignment in ONOS - PASS
- 206.20 Verify IP address assignment from hosts - PASS
- 206.21 Verify reachability of connected internal IPv4 hosts - PASS
- 206.22 Verify reachability of connected internal IPv6 hosts - PASS
- 206.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.24 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.25 Kill ['spine101'] - PASS
- 206.26 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 206.27 Verify reachability of connected internal IPv4 hosts - PASS
- 206.28 Verify reachability of connected internal IPv6 hosts - PASS
- 206.29 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.30 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.31 Verify host IP address assignment in ONOS - PASS
- 206.32 Verify IP address assignment from hosts - PASS
- 206.33 Verify reachability of connected internal IPv4 hosts - PASS
- 206.34 Verify reachability of connected internal IPv6 hosts - PASS
- 206.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.36 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.37 Recovering ['spine101'] - PASS
- 206.38 Check number of topology elements - PASS
- 206.39 Verify reachability of connected internal IPv4 hosts - PASS
- 206.40 Verify reachability of connected internal IPv6 hosts - PASS
- 206.41 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.42 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.43 Verify host IP address assignment in ONOS - PASS
- 206.44 Verify IP address assignment from hosts - PASS
- 206.45 Verify reachability of connected internal IPv4 hosts - PASS
- 206.46 Verify reachability of connected internal IPv6 hosts - PASS
- 206.47 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.48 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.49 Kill ['spine102'] - PASS
- 206.50 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 206.51 Verify reachability of connected internal IPv4 hosts - PASS
- 206.52 Verify reachability of connected internal IPv6 hosts - PASS
- 206.53 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.54 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.55 Verify host IP address assignment in ONOS - PASS
- 206.56 Verify IP address assignment from hosts - PASS
- 206.57 Verify reachability of connected internal IPv4 hosts - PASS
- 206.58 Verify reachability of connected internal IPv6 hosts - PASS
- 206.59 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.60 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.61 Recovering ['spine102'] - PASS
- 206.62 Check number of topology elements - PASS
- 206.63 Verify reachability of connected internal IPv4 hosts - PASS
- 206.64 Verify reachability of connected internal IPv6 hosts - PASS
- 206.65 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.66 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.67 Verify host IP address assignment in ONOS - PASS
- 206.68 Verify IP address assignment from hosts - PASS
- 206.69 Verify reachability of connected internal IPv4 hosts - PASS
- 206.70 Verify reachability of connected internal IPv6 hosts - PASS
- 206.71 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 206.72 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 206.73 Stopping Mininet - PASS
Case 207: Test switch failures with IPv4 hosts including external hosts configured with route-add command - FAIL
- 207.1 Apply cell to environment - PASS
- 207.2 Uninstalling Atomix - PASS
- 207.3 Uninstalling ONOS package - PASS
- 207.4 Installing Atomix - PASS
- 207.5 Installing ONOS package - PASS
- 207.6 Set up ONOS secure SSH - PASS
- 207.7 Checking ONOS service - PASS
- 207.8 Starting ONOS CLI sessions - PASS
- 207.9 Checking ONOS nodes - PASS
- 207.10 Checking ONOS applications - PASS
- 207.11 Set logging levels - PASS
- 207.12 Set ONOS configurations - PASS
- 207.13 Starting Mininet Topology - PASS
- 207.14 Check number of topology elements - PASS
- 207.15 Verify reachability of connected internal IPv4 hosts - PASS
- 207.16 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.17 Verify host IP address assignment in ONOS - PASS
- 207.18 Verify IP address assignment from hosts - PASS
- 207.19 Verify reachability of connected internal IPv4 hosts - PASS
- 207.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.21 Kill ['spine101'] - PASS
- 207.22 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 207.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.24 Verify host IP address assignment in ONOS - PASS
- 207.25 Verify IP address assignment from hosts - PASS
- 207.26 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.27 Recovering ['spine101'] - PASS
- 207.28 Check number of topology elements - PASS
- 207.29 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.30 Verify host IP address assignment in ONOS - PASS
- 207.31 Verify IP address assignment from hosts - PASS
- 207.32 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.33 Kill ['spine102'] - PASS
- 207.34 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 207.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.36 Verify host IP address assignment in ONOS - PASS
- 207.37 Verify IP address assignment from hosts - PASS
- 207.38 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.39 Recovering ['spine102'] - PASS
- 207.40 Check number of topology elements - PASS
- 207.41 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.42 Verify host IP address assignment in ONOS - PASS
- 207.43 Verify IP address assignment from hosts - PASS
- 207.44 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.45 Stopping Mininet - PASS
Case 208: Test switch failures with IPv6 hosts including external hosts configured with route-add command - FAIL
- 208.1 Apply cell to environment - PASS
- 208.2 Uninstalling Atomix - PASS
- 208.3 Uninstalling ONOS package - PASS
- 208.4 Installing Atomix - PASS
- 208.5 Installing ONOS package - PASS
- 208.6 Set up ONOS secure SSH - PASS
- 208.7 Checking ONOS service - PASS
- 208.8 Starting ONOS CLI sessions - PASS
- 208.9 Checking ONOS nodes - PASS
- 208.10 Checking ONOS applications - PASS
- 208.11 Set logging levels - PASS
- 208.12 Set ONOS configurations - PASS
- 208.13 Starting Mininet Topology - PASS
- 208.14 Check number of topology elements - PASS
- 208.15 Verify reachability of connected internal IPv6 hosts - PASS
- 208.16 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.17 Verify host IP address assignment in ONOS - PASS
- 208.18 Verify IP address assignment from hosts - PASS
- 208.19 Verify reachability of connected internal IPv6 hosts - PASS
- 208.20 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.21 Kill ['spine101'] - PASS
- 208.22 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 208.23 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.24 Verify host IP address assignment in ONOS - PASS
- 208.25 Verify IP address assignment from hosts - PASS
- 208.26 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.27 Recovering ['spine101'] - PASS
- 208.28 Check number of topology elements - PASS
- 208.29 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.30 Verify host IP address assignment in ONOS - PASS
- 208.31 Verify IP address assignment from hosts - PASS
- 208.32 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.33 Kill ['spine102'] - PASS
- 208.34 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 208.35 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.36 Verify host IP address assignment in ONOS - PASS
- 208.37 Verify IP address assignment from hosts - PASS
- 208.38 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.39 Recovering ['spine102'] - PASS
- 208.40 Check number of topology elements - PASS
- 208.41 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.42 Verify host IP address assignment in ONOS - PASS
- 208.43 Verify IP address assignment from hosts - PASS
- 208.44 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 208.45 Stopping Mininet - PASS
Case 209: Test switch failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL
- 209.1 Apply cell to environment - PASS
- 209.2 Uninstalling Atomix - PASS
- 209.3 Uninstalling ONOS package - PASS
- 209.4 Installing Atomix - PASS
- 209.5 Installing ONOS package - PASS
- 209.6 Set up ONOS secure SSH - PASS
- 209.7 Checking ONOS service - PASS
- 209.8 Starting ONOS CLI sessions - PASS
- 209.9 Checking ONOS nodes - PASS
- 209.10 Checking ONOS applications - PASS
- 209.11 Set logging levels - PASS
- 209.12 Set ONOS configurations - PASS
- 209.13 Starting Mininet Topology - PASS
- 209.14 Check number of topology elements - PASS
- 209.15 Verify reachability of connected internal IPv4 hosts - PASS
- 209.16 Verify reachability of connected internal IPv6 hosts - PASS
- 209.17 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.18 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.19 Verify host IP address assignment in ONOS - PASS
- 209.20 Verify IP address assignment from hosts - PASS
- 209.21 Verify reachability of connected internal IPv4 hosts - PASS
- 209.22 Verify reachability of connected internal IPv6 hosts - PASS
- 209.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.24 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.25 Kill ['spine101'] - PASS
- 209.26 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 209.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.28 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.29 Verify host IP address assignment in ONOS - PASS
- 209.30 Verify IP address assignment from hosts - PASS
- 209.31 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.32 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.33 Recovering ['spine101'] - PASS
- 209.34 Check number of topology elements - PASS
- 209.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.36 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.37 Verify host IP address assignment in ONOS - PASS
- 209.38 Verify IP address assignment from hosts - PASS
- 209.39 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.40 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.41 Kill ['spine102'] - PASS
- 209.42 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 9 devices (10 expected) and 30 links (48 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 209.43 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.44 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.45 Verify host IP address assignment in ONOS - PASS
- 209.46 Verify IP address assignment from hosts - PASS
- 209.47 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.48 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.49 Recovering ['spine102'] - PASS
- 209.50 Check number of topology elements - PASS
- 209.51 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.52 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.53 Verify host IP address assignment in ONOS - PASS
- 209.54 Verify IP address assignment from hosts - PASS
- 209.55 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 209.56 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 209.57 Stopping Mininet - PASS
Case 301: Test onos failures with IPv4 hosts - FAIL
- 301.1 Apply cell to environment - PASS
- 301.2 Uninstalling Atomix - PASS
- 301.3 Uninstalling ONOS package - PASS
- 301.4 Installing Atomix - PASS
- 301.5 Installing ONOS package - PASS
- 301.6 Set up ONOS secure SSH - PASS
- 301.7 Checking ONOS service - PASS
- 301.8 Starting ONOS CLI sessions - PASS
- 301.9 Checking ONOS nodes - PASS
- 301.10 Checking ONOS applications - PASS
- 301.11 Set logging levels - PASS
- 301.12 Set ONOS configurations - PASS
- 301.13 Starting Mininet Topology - PASS
- 301.14 Check number of topology elements - PASS
- 301.15 Verify reachability of connected internal IPv4 hosts - PASS
- 301.16 Verify host IP address assignment in ONOS - PASS
- 301.17 Verify IP address assignment from hosts - PASS
- 301.18 Verify reachability of connected internal IPv4 hosts - PASS
- 301.19 Killing ONOS instances with index(es): [0] - PASS
- 301.20 Check number of topology elements - PASS
- 301.21 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 301.22 Verify reachability of connected internal IPv4 hosts - PASS
- 301.23 Verify host IP address assignment in ONOS - PASS
- 301.24 Verify IP address assignment from hosts - PASS
- 301.25 Verify reachability of connected internal IPv4 hosts - PASS
- 301.26 Recovering ONOS instances with index(es): [0] - PASS
- 301.27 Checking if ONOS CLI is ready - PASS
- 301.28 Checking ONOS nodes - PASS
- 301.29 Check number of topology elements - PASS
- 301.30 Check number of topology elements - PASS
- 301.31 Verify reachability of connected internal IPv4 hosts - PASS
- 301.32 Verify host IP address assignment in ONOS - PASS
- 301.33 Verify IP address assignment from hosts - PASS
- 301.34 Verify reachability of connected internal IPv4 hosts - PASS
- 301.35 Killing ONOS instances with index(es): [1] - PASS
- 301.36 Check number of topology elements - PASS
- 301.37 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 301.38 Verify reachability of connected internal IPv4 hosts - PASS
- 301.39 Verify host IP address assignment in ONOS - PASS
- 301.40 Verify IP address assignment from hosts - PASS
- 301.41 Verify reachability of connected internal IPv4 hosts - PASS
- 301.42 Recovering ONOS instances with index(es): [1] - PASS
- 301.43 Checking if ONOS CLI is ready - PASS
- 301.44 Checking ONOS nodes - PASS
- 301.45 Check number of topology elements - PASS
- 301.46 Check number of topology elements - PASS
- 301.47 Verify reachability of connected internal IPv4 hosts - PASS
- 301.48 Verify host IP address assignment in ONOS - PASS
- 301.49 Verify IP address assignment from hosts - PASS
- 301.50 Verify reachability of connected internal IPv4 hosts - PASS
- 301.51 Killing ONOS instances with index(es): [2] - PASS
- 301.52 Check number of topology elements - PASS
- 301.53 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 301.54 Verify reachability of connected internal IPv4 hosts - PASS
- 301.55 Verify host IP address assignment in ONOS - PASS
- 301.56 Verify IP address assignment from hosts - PASS
- 301.57 Verify reachability of connected internal IPv4 hosts - PASS
- 301.58 Recovering ONOS instances with index(es): [2] - PASS
- 301.59 Checking if ONOS CLI is ready - PASS
- 301.60 Checking ONOS nodes - PASS
- 301.61 Check number of topology elements - PASS
- 301.62 Check number of topology elements - PASS
- 301.63 Verify reachability of connected internal IPv4 hosts - PASS
- 301.64 Verify host IP address assignment in ONOS - PASS
- 301.65 Verify IP address assignment from hosts - PASS
- 301.66 Verify reachability of connected internal IPv4 hosts - PASS
- 301.67 Stopping Mininet - PASS
Case 302: Test onos failures with IPv6 hosts - FAIL
- 302.1 Apply cell to environment - PASS
- 302.2 Uninstalling Atomix - PASS
- 302.3 Uninstalling ONOS package - PASS
- 302.4 Installing Atomix - PASS
- 302.5 Installing ONOS package - PASS
- 302.6 Set up ONOS secure SSH - PASS
- 302.7 Checking ONOS service - PASS
- 302.8 Starting ONOS CLI sessions - PASS
- 302.9 Checking ONOS nodes - PASS
- 302.10 Checking ONOS applications - PASS
- 302.11 Set logging levels - PASS
- 302.12 Set ONOS configurations - PASS
- 302.13 Starting Mininet Topology - PASS
- 302.14 Check number of topology elements - PASS
- 302.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 302.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 303: Test onos failures with IPv4 and IPv6 hosts - FAIL
- 303.1 Apply cell to environment - PASS
- 303.2 Uninstalling Atomix - PASS
- 303.3 Uninstalling ONOS package - PASS
- 303.4 Installing Atomix - PASS
- 303.5 Installing ONOS package - PASS
- 303.6 Set up ONOS secure SSH - PASS
- 303.7 Checking ONOS service - PASS
- 303.8 Starting ONOS CLI sessions - PASS
- 303.9 Checking ONOS nodes - PASS
- 303.10 Checking ONOS applications - PASS
- 303.11 Set logging levels - PASS
- 303.12 Set ONOS configurations - PASS
- 303.13 Starting Mininet Topology - PASS
- 303.14 Check number of topology elements - PASS
- 303.15 Verify reachability of connected internal IPv4 hosts - FAIL
- Verify reachability of connected internal IPv4 hosts: Fail
- 303.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 304: Test onos failures with IPv4 hosts including external hosts - FAIL
- 304.1 Apply cell to environment - PASS
- 304.2 Uninstalling Atomix - PASS
- 304.3 Uninstalling ONOS package - PASS
- 304.4 Installing Atomix - PASS
- 304.5 Installing ONOS package - PASS
- 304.6 Set up ONOS secure SSH - PASS
- 304.7 Checking ONOS service - PASS
- 304.8 Starting ONOS CLI sessions - PASS
- 304.9 Checking ONOS nodes - PASS
- 304.10 Checking ONOS applications - PASS
- 304.11 Set logging levels - PASS
- 304.12 Set ONOS configurations - PASS
- 304.13 Starting Mininet Topology - PASS
- 304.14 Check number of topology elements - PASS
- 304.15 Verify reachability of connected internal IPv4 hosts - PASS
- 304.16 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.17 Verify host IP address assignment in ONOS - PASS
- 304.18 Verify IP address assignment from hosts - PASS
- 304.19 Verify reachability of connected internal IPv4 hosts - PASS
- 304.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.21 Killing ONOS instances with index(es): [0] - PASS
- 304.22 Check number of topology elements - PASS
- 304.23 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 304.24 Verify reachability of connected internal IPv4 hosts - PASS
- 304.25 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.26 Verify host IP address assignment in ONOS - PASS
- 304.27 Verify IP address assignment from hosts - PASS
- 304.28 Verify reachability of connected internal IPv4 hosts - PASS
- 304.29 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.30 Recovering ONOS instances with index(es): [0] - PASS
- 304.31 Checking if ONOS CLI is ready - PASS
- 304.32 Checking ONOS nodes - PASS
- 304.33 Check number of topology elements - PASS
- 304.34 Check number of topology elements - PASS
- 304.35 Verify reachability of connected internal IPv4 hosts - PASS
- 304.36 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.37 Verify host IP address assignment in ONOS - PASS
- 304.38 Verify IP address assignment from hosts - PASS
- 304.39 Verify reachability of connected internal IPv4 hosts - PASS
- 304.40 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.41 Killing ONOS instances with index(es): [1] - PASS
- 304.42 Check number of topology elements - PASS
- 304.43 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 304.44 Verify reachability of connected internal IPv4 hosts - PASS
- 304.45 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.46 Verify host IP address assignment in ONOS - PASS
- 304.47 Verify IP address assignment from hosts - PASS
- 304.48 Verify reachability of connected internal IPv4 hosts - PASS
- 304.49 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.50 Recovering ONOS instances with index(es): [1] - PASS
- 304.51 Checking if ONOS CLI is ready - PASS
- 304.52 Checking ONOS nodes - PASS
- 304.53 Check number of topology elements - PASS
- 304.54 Check number of topology elements - PASS
- 304.55 Verify reachability of connected internal IPv4 hosts - PASS
- 304.56 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.57 Verify host IP address assignment in ONOS - PASS
- 304.58 Verify IP address assignment from hosts - PASS
- 304.59 Verify reachability of connected internal IPv4 hosts - PASS
- 304.60 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.61 Killing ONOS instances with index(es): [2] - PASS
- 304.62 Check number of topology elements - PASS
- 304.63 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 304.64 Verify reachability of connected internal IPv4 hosts - PASS
- 304.65 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.66 Verify host IP address assignment in ONOS - PASS
- 304.67 Verify IP address assignment from hosts - PASS
- 304.68 Verify reachability of connected internal IPv4 hosts - PASS
- 304.69 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.70 Recovering ONOS instances with index(es): [2] - PASS
- 304.71 Checking if ONOS CLI is ready - PASS
- 304.72 Checking ONOS nodes - PASS
- 304.73 Check number of topology elements - PASS
- 304.74 Check number of topology elements - PASS
- 304.75 Verify reachability of connected internal IPv4 hosts - PASS
- 304.76 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.77 Verify host IP address assignment in ONOS - PASS
- 304.78 Verify IP address assignment from hosts - PASS
- 304.79 Verify reachability of connected internal IPv4 hosts - PASS
- 304.80 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.81 Stopping Mininet - PASS
Case 305: Test onos failures with IPv6 hosts including external hosts - FAIL
- 305.1 Apply cell to environment - PASS
- 305.2 Uninstalling Atomix - PASS
- 305.3 Uninstalling ONOS package - PASS
- 305.4 Installing Atomix - PASS
- 305.5 Installing ONOS package - PASS
- 305.6 Set up ONOS secure SSH - PASS
- 305.7 Checking ONOS service - PASS
- 305.8 Starting ONOS CLI sessions - PASS
- 305.9 Checking ONOS nodes - PASS
- 305.10 Checking ONOS applications - PASS
- 305.11 Set logging levels - PASS
- 305.12 Set ONOS configurations - PASS
- 305.13 Starting Mininet Topology - PASS
- 305.14 Check number of topology elements - PASS
- 305.15 Verify reachability of connected internal IPv6 hosts - PASS
- 305.16 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.17 Verify host IP address assignment in ONOS - PASS
- 305.18 Verify IP address assignment from hosts - PASS
- 305.19 Verify reachability of connected internal IPv6 hosts - PASS
- 305.20 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.21 Killing ONOS instances with index(es): [0] - PASS
- 305.22 Check number of topology elements - PASS
- 305.23 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 305.24 Verify reachability of connected internal IPv6 hosts - PASS
- 305.25 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.26 Verify host IP address assignment in ONOS - PASS
- 305.27 Verify IP address assignment from hosts - PASS
- 305.28 Verify reachability of connected internal IPv6 hosts - PASS
- 305.29 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.30 Recovering ONOS instances with index(es): [0] - PASS
- 305.31 Checking if ONOS CLI is ready - PASS
- 305.32 Checking ONOS nodes - PASS
- 305.33 Check number of topology elements - PASS
- 305.34 Check number of topology elements - PASS
- 305.35 Verify reachability of connected internal IPv6 hosts - PASS
- 305.36 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.37 Verify host IP address assignment in ONOS - PASS
- 305.38 Verify IP address assignment from hosts - PASS
- 305.39 Verify reachability of connected internal IPv6 hosts - PASS
- 305.40 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.41 Killing ONOS instances with index(es): [1] - PASS
- 305.42 Check number of topology elements - PASS
- 305.43 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 305.44 Verify reachability of connected internal IPv6 hosts - PASS
- 305.45 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.46 Verify host IP address assignment in ONOS - PASS
- 305.47 Verify IP address assignment from hosts - PASS
- 305.48 Verify reachability of connected internal IPv6 hosts - PASS
- 305.49 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.50 Recovering ONOS instances with index(es): [1] - PASS
- 305.51 Checking if ONOS CLI is ready - PASS
- 305.52 Checking ONOS nodes - PASS
- 305.53 Check number of topology elements - PASS
- 305.54 Check number of topology elements - PASS
- 305.55 Verify reachability of connected internal IPv6 hosts - PASS
- 305.56 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.57 Verify host IP address assignment in ONOS - PASS
- 305.58 Verify IP address assignment from hosts - PASS
- 305.59 Verify reachability of connected internal IPv6 hosts - PASS
- 305.60 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.61 Killing ONOS instances with index(es): [2] - PASS
- 305.62 Check number of topology elements - PASS
- 305.63 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 305.64 Verify reachability of connected internal IPv6 hosts - PASS
- 305.65 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.66 Verify host IP address assignment in ONOS - PASS
- 305.67 Verify IP address assignment from hosts - PASS
- 305.68 Verify reachability of connected internal IPv6 hosts - PASS
- 305.69 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.70 Recovering ONOS instances with index(es): [2] - PASS
- 305.71 Checking if ONOS CLI is ready - PASS
- 305.72 Checking ONOS nodes - PASS
- 305.73 Check number of topology elements - PASS
- 305.74 Check number of topology elements - PASS
- 305.75 Verify reachability of connected internal IPv6 hosts - PASS
- 305.76 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.77 Verify host IP address assignment in ONOS - PASS
- 305.78 Verify IP address assignment from hosts - PASS
- 305.79 Verify reachability of connected internal IPv6 hosts - PASS
- 305.80 Verify reachability from connected internal IPv6 hosts to external IPv6 hosts - PASS
- 305.81 Stopping Mininet - PASS
Case 306: Test onos failures with IPv4 and IPv6 hosts including external hosts - FAIL
- 306.1 Apply cell to environment - PASS
- 306.2 Uninstalling Atomix - PASS
- 306.3 Uninstalling ONOS package - PASS
- 306.4 Installing Atomix - PASS
- 306.5 Installing ONOS package - PASS
- 306.6 Set up ONOS secure SSH - PASS
- 306.7 Checking ONOS service - PASS
- 306.8 Starting ONOS CLI sessions - PASS
- 306.9 Checking ONOS nodes - PASS
- 306.10 Checking ONOS applications - PASS
- 306.11 Set logging levels - PASS
- 306.12 Set ONOS configurations - PASS
- 306.13 Starting Mininet Topology - PASS
- 306.14 Check number of topology elements - PASS
- 306.15 Verify reachability of connected internal IPv4 hosts - PASS
- 306.16 Verify reachability of connected internal IPv6 hosts - PASS
- 306.17 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - FAIL
- Verify reachability from connected internal IPv4 hosts to external IPv4 hosts: Fail
- 306.18 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 307: Test onos failures with IPv4 hosts including external hosts configured with route-add command - FAIL
- 307.1 Apply cell to environment - PASS
- 307.2 Uninstalling Atomix - PASS
- 307.3 Uninstalling ONOS package - PASS
- 307.4 Installing Atomix - PASS
- 307.5 Installing ONOS package - PASS
- 307.6 Set up ONOS secure SSH - PASS
- 307.7 Checking ONOS service - PASS
- 307.8 Starting ONOS CLI sessions - PASS
- 307.9 Checking ONOS nodes - PASS
- 307.10 Checking ONOS applications - PASS
- 307.11 Set logging levels - PASS
- 307.12 Set ONOS configurations - PASS
- 307.13 Starting Mininet Topology - PASS
- 307.14 Check number of topology elements - PASS
- 307.15 Verify reachability of connected internal IPv4 hosts - PASS
- 307.16 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.17 Verify host IP address assignment in ONOS - PASS
- 307.18 Verify IP address assignment from hosts - PASS
- 307.19 Verify reachability of connected internal IPv4 hosts - PASS
- 307.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.21 Killing ONOS instances with index(es): [0] - PASS
- 307.22 Check number of topology elements - PASS
- 307.23 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 307.24 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.25 Verify host IP address assignment in ONOS - PASS
- 307.26 Verify IP address assignment from hosts - PASS
- 307.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.28 Recovering ONOS instances with index(es): [0] - PASS
- 307.29 Checking if ONOS CLI is ready - PASS
- 307.30 Checking ONOS nodes - PASS
- 307.31 Check number of topology elements - PASS
- 307.32 Check number of topology elements - PASS
- 307.33 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.34 Verify host IP address assignment in ONOS - PASS
- 307.35 Verify IP address assignment from hosts - PASS
- 307.36 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.37 Killing ONOS instances with index(es): [1] - PASS
- 307.38 Check number of topology elements - PASS
- 307.39 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 307.40 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.41 Verify host IP address assignment in ONOS - PASS
- 307.42 Verify IP address assignment from hosts - PASS
- 307.43 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.44 Recovering ONOS instances with index(es): [1] - PASS
- 307.45 Checking if ONOS CLI is ready - PASS
- 307.46 Checking ONOS nodes - PASS
- 307.47 Check number of topology elements - PASS
- 307.48 Check number of topology elements - PASS
- 307.49 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.50 Verify host IP address assignment in ONOS - PASS
- 307.51 Verify IP address assignment from hosts - PASS
- 307.52 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.53 Killing ONOS instances with index(es): [2] - PASS
- 307.54 Check number of topology elements - PASS
- 307.55 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 10 devices (10 expected) and 48 links (48 expected) and 2 controllers (3 expected) and 1 SCCs (1 expected)
- 307.56 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.57 Verify host IP address assignment in ONOS - PASS
- 307.58 Verify IP address assignment from hosts - PASS
- 307.59 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.60 Recovering ONOS instances with index(es): [2] - PASS
- 307.61 Checking if ONOS CLI is ready - PASS
- 307.62 Checking ONOS nodes - PASS
- 307.63 Check number of topology elements - PASS
- 307.64 Check number of topology elements - PASS
- 307.65 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.66 Verify host IP address assignment in ONOS - PASS
- 307.67 Verify IP address assignment from hosts - PASS
- 307.68 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.69 Stopping Mininet - PASS
Case 308: Test onos failures with IPv6 hosts including external hosts configured with route-add command - FAIL
- 308.1 Apply cell to environment - PASS
- 308.2 Uninstalling Atomix - PASS
- 308.3 Uninstalling ONOS package - PASS
- 308.4 Installing Atomix - PASS
- 308.5 Installing ONOS package - PASS
- 308.6 Set up ONOS secure SSH - PASS
- 308.7 Checking ONOS service - PASS
- 308.8 Starting ONOS CLI sessions - PASS
- 308.9 Checking ONOS nodes - PASS
- 308.10 Checking ONOS applications - PASS
- 308.11 Set logging levels - PASS
- 308.12 Set ONOS configurations - PASS
- 308.13 Starting Mininet Topology - PASS
- 308.14 Check number of topology elements - PASS
- 308.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 308.16 Stopping Mininet - PASS
- Skipping the rest of this case.