Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 56 Next »

SRClusterRestart at 11 Jul 2021 00:22:40

SRClusterRestart

commit f0d00d5e5dfd9576bdbfa826bc81cd168f0589b1 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Jian Li [pyguni@gmail.com]
AuthorDate: Thu Jul 8 20:52:50 2021 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Thu Jul 8 12:39:54 2021 +0000

Change the logic of synchronizing flow rules on kubevirt network

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is >= 116 - PASS (tick)
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.21 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.25 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.26 Checking if ONOS CLI is ready - PASS (tick)
  • 1.27 Checking if ONOS CLI is ready - PASS (tick)
  • 1.28 Checking if ONOS CLI is ready - PASS (tick)
  • 1.29 Checking ONOS nodes - PASS (tick)
  • 1.30 Check number of topology elements - PASS (tick)
  • 1.31 Check whether the flow count is >= 116 - PASS (tick)
  • 1.32 Check whether all flow status are ADDED - PASS (tick)
  • 1.33 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.36 Stopping Mininet - PASS (tick)
  • 1.37 Copying karaf logs - PASS (tick)

Case 2: Cluster Restart test with 4x4 Leaf-spine - FAIL

Case 2: Cluster Restart test with 4x4 Leaf-spine - FAIL

Case 2: Cluster Restart test with 4x4 Leaf-spine - FAIL

Case 2: Cluster Restart test with 4x4 Leaf-spine - FAIL

  • No labels