SRBridging at 21 Sep 2018 19:31:48

SRBridging

commit 4a92c0d0130aab3781a2203782bd42006d9f1acf (HEAD -] onos-1.14, origin/onos-1.14)
Author: Charles Chan [rascov@gmail.com]
AuthorDate: Fri Sep 21 11:29:12 2018 -0700
Commit: Charles Chan [rascov@gmail.com]
CommitDate: Fri Sep 21 16:08:32 2018 -0700

Fix serialization issue

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Starting Mininet Topology - PASS (tick)
  • 5.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.15 Check whether all flow status are ADDED - PASS (tick)
  • 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR and 3 ONOS instances - PASS

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Starting Mininet Topology - PASS (tick)
  • 6.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.13 Check whether all flow status are ADDED - PASS (tick)
  • 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.17 Stopping Mininet - PASS (tick)
  • 6.18 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Starting Mininet Topology - PASS (tick)
  • 7.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.13 Check whether all flow status are ADDED - PASS (tick)
  • 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.18 Stopping Mininet - PASS (tick)
  • 7.19 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances - PASS

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Starting Mininet Topology - PASS (tick)
  • 8.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.13 Check whether all flow status are ADDED - PASS (tick)
  • 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.20 Stopping Mininet - PASS (tick)
  • 8.21 Copying karaf logs - PASS (tick)

Case 15: Bridging test between two tagged hosts, with single ToR and 3 ONOS instances - PASS

  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling Atomix - PASS (tick)
  • 15.3 Uninstalling ONOS package - PASS (tick)
  • 15.4 Installing Atomix - PASS (tick)
  • 15.5 Installing ONOS package - PASS (tick)
  • 15.6 Set up ONOS secure SSH - PASS (tick)
  • 15.7 Checking ONOS service - PASS (tick)
  • 15.8 Starting ONOS CLI sessions - PASS (tick)
  • 15.9 Checking ONOS nodes - PASS (tick)
  • 15.10 Checking ONOS applications - PASS (tick)
  • 15.11 Starting Mininet Topology - PASS (tick)
  • 15.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 15.13 Check whether all flow status are ADDED - PASS (tick)
  • 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS (tick)
  • 15.16 Stopping Mininet - PASS (tick)
  • 15.17 Copying karaf logs - PASS (tick)

Case 16: Bridging test between two tagged hosts, with dual-homed ToR and 3 ONOS instances - PASS

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Starting Mininet Topology - PASS (tick)
  • 16.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 16.13 Check whether all flow status are ADDED - PASS (tick)
  • 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.17 Stopping Mininet - PASS (tick)
  • 16.18 Copying karaf logs - PASS (tick)

Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Starting Mininet Topology - PASS (tick)
  • 17.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.13 Check whether all flow status are ADDED - PASS (tick)
  • 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)
  • 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)
  • 17.18 Stopping Mininet - PASS (tick)
  • 17.19 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances - FAIL

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Starting Mininet Topology - PASS (tick)
  • 18.12 Check whether the flow count is bigger than 212 - FAIL (error)
    • Flow count looks wrong: False
  • 18.13 Check whether all flow status are ADDED - PASS (tick)
  • 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - FAIL (error)
    • IP connectivity failed
  • 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - FAIL (error)
    • IP connectivity failed
  • 18.20 Stopping Mininet - PASS (tick)
  • 18.21 Copying karaf logs - PASS (tick)

Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances - PASS

  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling Atomix - PASS (tick)
  • 25.3 Uninstalling ONOS package - PASS (tick)
  • 25.4 Installing Atomix - PASS (tick)
  • 25.5 Installing ONOS package - PASS (tick)
  • 25.6 Set up ONOS secure SSH - PASS (tick)
  • 25.7 Checking ONOS service - PASS (tick)
  • 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 25.9 Checking ONOS nodes - PASS (tick)
  • 25.10 Checking ONOS applications - PASS (tick)
  • 25.11 Starting Mininet Topology - PASS (tick)
  • 25.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 25.13 Check whether all flow status are ADDED - PASS (tick)
  • 25.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 25.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS (tick)
  • 25.16 Stopping Mininet - PASS (tick)
  • 25.17 Copying karaf logs - PASS (tick)

Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR and 3 ONOS instances - FAIL