Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

SRBridging at 04 Jan 2019 19:32:03

SRBridging

commit 2ea2a92271da2184b936960302668d3a4978fa19 (HEAD -] onos-2.0, origin/onos-2.0)
Author: Thomas Vachuska [tom@opennetworking.org]
AuthorDate: Thu Jan 3 16:26:53 2019 -0800
Commit: Ray Milkey [ray@opennetworking.org]
CommitDate: Fri Jan 4 21:54:50 2019 +0000

Fixing archetypes to compensate for missing transitive dependencies in pom.xml files.

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Starting Mininet Topology - PASS (tick)
  • 5.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.15 Check whether all flow status are ADDED - PASS (tick)
  • 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR and 3 ONOS instances - PASS

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Starting Mininet Topology - PASS (tick)
  • 6.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.13 Check whether all flow status are ADDED - PASS (tick)
  • 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.17 Stopping Mininet - PASS (tick)
  • 6.18 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Starting Mininet Topology - PASS (tick)
  • 7.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.13 Check whether all flow status are ADDED - PASS (tick)
  • 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
    • Flow count looks wrong.
  • 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - FAIL (error)
    • IP connectivity failed
  • 7.18 Stopping Mininet - PASS (tick)
  • 7.19 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances - PASS

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Starting Mininet Topology - PASS (tick)
  • 8.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.13 Check whether all flow status are ADDED - PASS (tick)
  • 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.20 Stopping Mininet - PASS (tick)
  • 8.21 Copying karaf logs - PASS (tick)

Case 15: Bridging test between two tagged hosts, with single ToR and 3 ONOS instances - PASS

  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling Atomix - PASS (tick)
  • 15.3 Uninstalling ONOS package - PASS (tick)
  • 15.4 Installing Atomix - PASS (tick)
  • 15.5 Installing ONOS package - PASS (tick)
  • 15.6 Set up ONOS secure SSH - PASS (tick)
  • 15.7 Checking ONOS service - PASS (tick)
  • 15.8 Starting ONOS CLI sessions - PASS (tick)
  • 15.9 Checking ONOS nodes - PASS (tick)
  • 15.10 Checking ONOS applications - PASS (tick)
  • 15.11 Starting Mininet Topology - PASS (tick)
  • 15.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 15.13 Check whether all flow status are ADDED - PASS (tick)
  • 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS (tick)
  • 15.16 Stopping Mininet - PASS (tick)
  • 15.17 Copying karaf logs - PASS (tick)

Case 16: Bridging test between two tagged hosts, with dual-homed ToR and 3 ONOS instances - PASS

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Starting Mininet Topology - PASS (tick)
  • 16.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 16.13 Check whether all flow status are ADDED - PASS (tick)
  • 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.17 Stopping Mininet - PASS (tick)
  • 16.18 Copying karaf logs - PASS (tick)

Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • No labels