Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 9 Next »

SRSwitchFailure at 19 Jan 2019 10:59:55

SRSwitchFailure

commit 9d6fd7516a88f572f8a361e8348ead624aef9636 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Andrea Campanella [andrea@opennetworking.org]
AuthorDate: Thu Jan 17 16:05:03 2019 +0100
Commit: Andrea Campanella [andrea@opennetworking.org]
CommitDate: Fri Jan 18 09:38:26 2019 +0100

Enabling REST API and swagger docs for apps with no resources folder
--
(cherry picked from commit 4005c060d5520182d6849a4b7df61d0561664c5f)

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.19 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.23 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 1.24 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.25 Check whether all flow status are ADDED - PASS (tick)
  • 1.26 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS (tick)
  • 1.28 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS (tick)
  • 1.29 Stopping Mininet - PASS (tick)
  • 1.30 Copying karaf logs - PASS (tick)

Case 2: Switch Failure test with 4x4 Leaf-spine and 1 Onos - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 2.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 2.23 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.24 Check whether all flow status are ADDED - PASS (tick)
  • 2.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - PASS (tick)
  • 2.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - PASS (tick)
  • 2.28 Stopping Mininet - PASS (tick)
  • 2.29 Copying karaf logs - PASS (tick)

Case 4: Switch Failure test with 2x2 Leaf-spine and 3 Onos - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 4.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Failure - FAIL (error)
    • IP connectivity failed
  • 4.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Failure - PASS (tick)
  • 4.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Failure - PASS (tick)
  • 4.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 4.23 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.24 Check whether all flow status are ADDED - PASS (tick)
  • 4.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Recovery - PASS (tick)
  • 4.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Recovery - PASS (tick)
  • 4.28 Stopping Mininet - PASS (tick)
  • 4.29 Copying karaf logs - PASS (tick)

Case 5: Switch Failure test with 4x4 Leaf-spine and 3 Onos - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Starting Mininet Topology - PASS (tick)
  • 5.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.14 Check whether all flow status are ADDED - PASS (tick)
  • 5.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 5.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - PASS (tick)
  • 5.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - PASS (tick)
  • 5.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 5.23 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.24 Check whether all flow status are ADDED - PASS (tick)
  • 5.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - PASS (tick)
  • 5.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - PASS (tick)
  • 5.28 Stopping Mininet - PASS (tick)
  • 5.29 Copying karaf logs - PASS (tick)
  • No labels