Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 21 Next »

**************************************

Jenkins test result for 03:46 on Mar 25, 2015.

Test MultiProd13

************************************

Result summary for Testcase1

This testcase is testing setting up test environment

__________________________________

commit 9689126958f79f2df1cb25073319ea535d2bcf4e (HEAD, origin/master, origin/HEAD, master)

Author: Thomas Vachuska [tom@onlab.us]

AuthorDate: Tue Mar 24 17:22:03 2015 -0700

Commit: Gerrit Code Review [gerrit@onlab.us]

CommitDate: Wed Mar 25 01:48:40 2015 +0000

ONOS-1376 FIxed error in app command to report bad usage better.

Installing ONOS package successful

ONOS instances are up and ready

Result: Pass

Result summary for Testcase4

This testcase is testing the assignment of all the switches to all controllers and discovering the hosts in reactive mode

__________________________________

Controller assignment successfull

Pingall Test in reactive mode to discover the hosts failed

Controller assignment and Pingall Test NOT successful

Result: Failed

Result summary for Testcase10

This testcase uninstalls the reactive forwarding app

__________________________________

Result: Pass

Result summary for Testcase5

This testcase is testing if all ONOS nodes are in topologyi sync with mininet and its peer ONOS nodes

__________________________________

Mininet has 29 bidirectional links and ONOS has 54 unidirectional links

ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

ONOS1 Links view is incorrect

Mininet has 29 bidirectional links and ONOS has 54 unidirectional links

ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

ONOS2 Links view is incorrect

Mininet has 29 bidirectional links and ONOS has 54 unidirectional links

ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

ONOS2 Links view is incorrect

Topology Check Test with mininet and ONOS instances failed

Topology Check Test NOT successful

Result: Failed

Result summary for Testcase6

This testcase is testing the addition of host intents and then doing pingall

__________________________________

Result: Failed

Result summary for Testcase7

This testscase is killing a link to ensure that link discovery is consistent

__________________________________

  • No labels