Jenkins test result for 22:28 on Apr 01, 2015.

Test Plan for HA Test Cases

  • HATestSanity - Results: 19 Passed, 6 Failed
  • HATestMinorityRestart - Results: 15 Passed, 10 Failed
  • HATestClusterRestart - Results: 14 Passed, 12 Failed
  • HATestSingleInstanceRestart - Results: 24 Passed, 2 Failed
  • Test HATestSanity

    ************************************

    Result summary for Testcase1

    ONOS HA Sanity test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit a36f03bf8f17c0c7c2d7d87b08f50dab9894cd40 (HEAD, origin/master, origin/HEAD, master)

    Author: Simon Hunt [simon@onlab.us]

    AuthorDate: Wed Apr 1 15:22:49 2015 -0700

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Apr 2 00:06:51 2015 +0000

    GUI -- Augmented the link details display.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Error in pushing host intents to ONOS

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents not consistent

    ONOS nodes have different views of intents

    Flow count is consistent across all ONOS nodes

    State check NOT successful

    Result: Failed

    Result summary for Testcase14

    Leadership election tests passed( consistent view of leader across listeners and a leader was elected )

    Result: Pass

    Result summary for Testcase6

    Wait 60 seconds instead of inducing a failure

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    The Intents changed during failure

    No changes were found in the flow tables

    No loss of dataplane connectivity

    Leadership election tests passed( consistent view of leader across listeners and a new leader was re-elected if applicable )

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase15

    Check that Leadership Election is still functional

    Leadership election tests passed( consistent view of leader across listeners and a new leader was elected when the old leader resigned )

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestMinorityRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart minority of ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit a36f03bf8f17c0c7c2d7d87b08f50dab9894cd40 (HEAD, origin/master, origin/HEAD, master)

    Author: Simon Hunt [simon@onlab.us]

    AuthorDate: Wed Apr 1 15:22:49 2015 -0700

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Apr 2 00:06:51 2015 +0000

    GUI -- Augmented the link details display.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Error in pushing host intents to ONOS

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents not consistent

    ONOS nodes have different views of intents

    Flow count is consistent across all ONOS nodes

    State check NOT successful

    Result: Failed

    Result summary for Testcase14

    Leadership election tests passed( consistent view of leader across listeners and a leader was elected )

    Result: Pass

    Result summary for Testcase6

    Killing 3 ONOS nodes

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    Intents are consistent across all ONOS nodes

    The Intents changed during failure

    Changes were found in the flow tables

    Loss of dataplane connectivity detected

    Leadership election tests passed( consistent view of leader across listeners and a new leader was re-elected if applicable )

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase15

    Check that Leadership Election is still functional

    Leadership election tests passed( consistent view of leader across listeners and a new leader was elected when the old leader resigned )

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 28 bidirectional links and ONOS has 57 unidirectional links

    ONOS7 links view is incorrect

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 26 bidirectional links and ONOS has 53 unidirectional links

    ONOS7 links view is incorrect

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS7 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS1 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS2 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS3 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS4 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS5 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS6 links view is incorrect

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 59 unidirectional links

    ONOS7 links view is incorrect

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestClusterRestart

    ************************************

    Result summary for Testcase1

    ONOS HA test: Restart all ONOS nodes - initialization

    Removing raft logs

    Uninstalling ONOS

    commit a36f03bf8f17c0c7c2d7d87b08f50dab9894cd40 (HEAD, origin/master, origin/HEAD, master)

    Author: Simon Hunt [simon@onlab.us]

    AuthorDate: Wed Apr 1 15:22:49 2015 -0700

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Apr 2 00:06:51 2015 +0000

    GUI -- Augmented the link details display.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Error in pushing host intents to ONOS

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Switch roles are consistent across all ONOS nodes

    Intents not consistent

    ONOS nodes have different views of intents

    Flow count is consistent across all ONOS nodes

    State check NOT successful

    Result: Failed

    Result summary for Testcase14

    Leadership election tests passed( consistent view of leader across listeners and a leader was elected )

    Result: Pass

    Result summary for Testcase6

    Restart entire ONOS cluster

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s8(0000000000003008) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 22 unidirectional links

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS2 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s8(0000000000003008) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 22 unidirectional links

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS2 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS3 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s8(0000000000003008) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 22 unidirectional links

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS3 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS4 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s8(0000000000003008) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 22 unidirectional links

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS4 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS5 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s8(0000000000003008) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 22 unidirectional links

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS5 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS6 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s8(0000000000003008) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 22 unidirectional links

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS6 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000006019']

    Switches in ONOS but not in MN:

    []

    ONOS7 Switches view is incorrect

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s8(0000000000003008) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 22 unidirectional links

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS7 links view is incorrect

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    clusters from ONOS6 is inconsistent with ONOS1

    clusters from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of clusters

    ONOS shows 26 SCCs

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 12 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS1 links view is incorrect

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 12 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS2 links view is incorrect

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 12 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS3 links view is incorrect

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 12 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS4 links view is incorrect

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 12 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS5 links view is incorrect

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 12 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS6 links view is incorrect

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 12 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS7 links view is incorrect

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    clusters from ONOS5 is inconsistent with ONOS1

    ONOS nodes have different views of clusters

    ONOS shows 25 SCCs

    Switches in MN but not in ONOS:

    ['0000000000003004']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004']

    Switches in ONOS but not in MN:

    []

    ONOS2 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS2 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004']

    Switches in ONOS but not in MN:

    []

    ONOS3 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS3 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004']

    Switches in ONOS but not in MN:

    []

    ONOS4 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS4 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004']

    Switches in ONOS but not in MN:

    []

    ONOS5 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS5 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004']

    Switches in ONOS but not in MN:

    []

    ONOS6 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS6 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004']

    Switches in ONOS but not in MN:

    []

    ONOS7 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s18(0000000000006018) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 5 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000002000/2 -> 0000000000005000/2

    ONOS does not have the link 0000000000002000/4 -> 0000000000003000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003004/10 -> 0000000000003015/2

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000001000/2 -> 0000000000002000/3

    ONOS does not have the link 0000000000002000/3 -> 0000000000001000/2

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006007/10 -> 0000000000006025/2

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006007/11 -> 0000000000006026/2

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS7 links view is incorrect

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    clusters from ONOS3 is inconsistent with ONOS1

    ONOS nodes have different views of clusters

    ONOS shows 27 SCCs

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007']

    Switches in ONOS but not in MN:

    []

    ONOS1 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 8 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS1 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007']

    Switches in ONOS but not in MN:

    []

    ONOS2 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 8 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS2 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007']

    Switches in ONOS but not in MN:

    []

    ONOS3 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 8 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS3 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007']

    Switches in ONOS but not in MN:

    []

    ONOS4 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 8 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS4 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007']

    Switches in ONOS but not in MN:

    []

    ONOS5 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 8 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS5 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007']

    Switches in ONOS but not in MN:

    []

    ONOS6 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 8 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS6 links view is incorrect

    Switches in MN but not in ONOS:

    ['0000000000003004', '0000000000006007']

    Switches in ONOS but not in MN:

    []

    ONOS7 Switches view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s4(0000000000003004) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s19(0000000000006019) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    Mininet has 29 bidirectional links and ONOS has 8 unidirectional links

    ONOS does not have the link 0000000000001000/3 -> 0000000000005000/3

    ONOS does not have the link 0000000000005000/3 -> 0000000000001000/3

    ONOS does not have the link 0000000000005000/2 -> 0000000000002000/2

    ONOS does not have the link 0000000000003000/2 -> 0000000000002000/4

    ONOS does not have the link 0000000000003000/3 -> 0000000000002800/2

    ONOS does not have the link 0000000000002800/2 -> 0000000000003000/3

    ONOS does not have the link 0000000000003000/4 -> 0000000000003004/2

    ONOS does not have the link 0000000000003004/2 -> 0000000000003000/4

    ONOS does not have the link 0000000000003004/3 -> 0000000000003008/2

    ONOS does not have the link 0000000000003008/2 -> 0000000000003004/3

    ONOS does not have the link 0000000000003004/4 -> 0000000000003009/2

    ONOS does not have the link 0000000000003009/2 -> 0000000000003004/4

    ONOS does not have the link 0000000000003004/5 -> 0000000000003010/2

    ONOS does not have the link 0000000000003010/2 -> 0000000000003004/5

    ONOS does not have the link 0000000000003004/6 -> 0000000000003011/2

    ONOS does not have the link 0000000000003011/2 -> 0000000000003004/6

    ONOS does not have the link 0000000000003004/7 -> 0000000000003012/2

    ONOS does not have the link 0000000000003012/2 -> 0000000000003004/7

    ONOS does not have the link 0000000000003015/2 -> 0000000000003004/10

    ONOS does not have the link 0000000000003004/8 -> 0000000000003013/2

    ONOS does not have the link 0000000000003013/2 -> 0000000000003004/8

    ONOS does not have the link 0000000000003004/9 -> 0000000000003014/2

    ONOS does not have the link 0000000000003014/2 -> 0000000000003004/9

    ONOS does not have the link 0000000000003004/11 -> 0000000000003016/2

    ONOS does not have the link 0000000000003016/2 -> 0000000000003004/11

    ONOS does not have the link 0000000000003004/12 -> 0000000000003017/2

    ONOS does not have the link 0000000000003017/2 -> 0000000000003004/12

    ONOS does not have the link 0000000000005000/4 -> 0000000000006000/2

    ONOS does not have the link 0000000000006000/2 -> 0000000000005000/4

    ONOS does not have the link 0000000000006000/3 -> 0000000000002800/3

    ONOS does not have the link 0000000000002800/3 -> 0000000000006000/3

    ONOS does not have the link 0000000000006000/4 -> 0000000000006007/2

    ONOS does not have the link 0000000000006007/2 -> 0000000000006000/4

    ONOS does not have the link 0000000000006007/3 -> 0000000000006018/2

    ONOS does not have the link 0000000000006018/2 -> 0000000000006007/3

    ONOS does not have the link 0000000000006007/4 -> 0000000000006019/2

    ONOS does not have the link 0000000000006019/2 -> 0000000000006007/4

    ONOS does not have the link 0000000000006007/5 -> 0000000000006020/2

    ONOS does not have the link 0000000000006020/2 -> 0000000000006007/5

    ONOS does not have the link 0000000000006007/6 -> 0000000000006021/2

    ONOS does not have the link 0000000000006007/7 -> 0000000000006022/2

    ONOS does not have the link 0000000000006022/2 -> 0000000000006007/7

    ONOS does not have the link 0000000000006007/8 -> 0000000000006023/2

    ONOS does not have the link 0000000000006023/2 -> 0000000000006007/8

    ONOS does not have the link 0000000000006007/9 -> 0000000000006024/2

    ONOS does not have the link 0000000000006024/2 -> 0000000000006007/9

    ONOS does not have the link 0000000000006025/2 -> 0000000000006007/10

    ONOS does not have the link 0000000000006026/2 -> 0000000000006007/11

    ONOS does not have the link 0000000000006007/12 -> 0000000000006027/2

    ONOS does not have the link 0000000000006027/2 -> 0000000000006007/12

    ONOS7 links view is incorrect

    hosts from ONOS2 is inconsistent with ONOS1

    hosts from ONOS3 is inconsistent with ONOS1

    hosts from ONOS4 is inconsistent with ONOS1

    hosts from ONOS5 is inconsistent with ONOS1

    hosts from ONOS6 is inconsistent with ONOS1

    hosts from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of hosts

    clusters from ONOS2 is inconsistent with ONOS1

    clusters from ONOS3 is inconsistent with ONOS1

    clusters from ONOS4 is inconsistent with ONOS1

    clusters from ONOS7 is inconsistent with ONOS1

    ONOS nodes have different views of clusters

    ONOS shows 25 SCCs

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase3

    Adding host intents

    Reactive Pingall failed, one or more ping pairs failed

    Reactive Pingall failed, one or more ping pairs failed

    Error in pushing host intents to ONOS

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of some switches changed

    ONOS nodes have different views of intents

    Changes were found in the flow tables

    Loss of dataplane connectivity detected

    Leadership election tests passed( consistent view of leader across listeners and a new leader was re-elected if applicable )

    Constant state tests failed

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase15

    Check that Leadership Election is still functional

    Leadership election tests passed( consistent view of leader across listeners and a new leader was elected when the old leader resigned )

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s5(0000000000005000) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS7 ports view is incorrect

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS7 ports view is incorrect

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    ONOS7 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS1 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS2 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS3 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS4 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS5 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS6 ports view is incorrect

    The list of ports for switch s7(0000000000006007) does not match:

    The list of ports for switch s6(0000000000006000) does not match:

    The list of ports for switch s13(0000000000003013) does not match:

    The list of ports for switch s12(0000000000003012) does not match:

    The list of ports for switch s10(0000000000003010) does not match:

    The list of ports for switch s16(0000000000003016) does not match:

    The list of ports for switch s15(0000000000003015) does not match:

    The list of ports for switch s9(0000000000003009) does not match:

    The list of ports for switch s23(0000000000006023) does not match:

    The list of ports for switch s25(0000000000006025) does not match:

    The list of ports for switch s22(0000000000006022) does not match:

    The list of ports for switch s3(0000000000003000) does not match:

    The list of ports for switch s20(0000000000006020) does not match:

    The list of ports for switch s21(0000000000006021) does not match:

    The list of ports for switch s26(0000000000006026) does not match:

    The list of ports for switch s24(0000000000006024) does not match:

    The list of ports for switch s2(0000000000002000) does not match:

    The list of ports for switch s28(0000000000002800) does not match:

    The list of ports for switch s1(0000000000001000) does not match:

    ONOS7 ports view is incorrect

    Topology Check Test NOT successful

    Result: Failed

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase13

    Test Cleanup

    Result: Pass

    Test HATestSingleInstanceRestart

    ************************************

    Result summary for Testcase1

    ONOS Single node cluster restart HA test - initialization

    Removing raft logs

    Uninstalling ONOS

    commit a36f03bf8f17c0c7c2d7d87b08f50dab9894cd40 (HEAD, origin/master, origin/HEAD, master)

    Author: Simon Hunt [simon@onlab.us]

    AuthorDate: Wed Apr 1 15:22:49 2015 -0700

    Commit: Gerrit Code Review [gerrit@onlab.us]

    CommitDate: Thu Apr 2 00:06:51 2015 +0000

    GUI -- Augmented the link details display.

    Result: Pass

    Result summary for Testcase2

    Assigning switches to controllers

    Switch mastership assigned correctly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase5

    Setting up and gathering data for current state

    Result: Pass

    Result summary for Testcase14

    Leadership election tests passed( consistent view of leader across listeners and a leader was elected )

    Result: Pass

    Result summary for Testcase6

    Restart ONOS node

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase3

    Adding host intents

    Result: Pass

    Result summary for Testcase7

    Switch roles are consistent across all ONOS nodes

    Mastership of Switches was not changed

    Intents are consistent across all ONOS nodes

    No changes were found in the flow tables

    Leadership election tests passed( consistent view of leader across listeners and a new leader was re-elected if applicable )

    Constant State Tests Passed

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase15

    Check that Leadership Election is still functional

    Leadership election tests passed( There is no leader after the old leader resigned )

    Result: Pass

    Result summary for Testcase9

    Turn off a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase10

    Restore a link to ensure that Link Discovery is working properly

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have not been installed correctly, pings failed.

    Intents have not been installed correctly, pings failed.

    Result: Failed

    Result summary for Testcase11

    Killing a switch to ensure it is discovered correctly

    Deleting s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase12

    Adding a switch to ensure it is discovered correctly

    Adding back s5

    Result: Pass

    Result summary for Testcase8

    Compare ONOS Topology view to Mininet topology

    ONOS topology view matches Mininet topology

    Result: Pass

    Result summary for Testcase4

    Ping across added host intents

    Intents have been installed correctly and verified by pings

    Result: Pass

    Result summary for Testcase13

    Test Cleanup

    Result: Pass