Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 56 Next »

FUNCoptical at 02 Jan 2016 21:11:05

commit 64dd8899398be768fb817297c584da556ffdf67d (HEAD, origin/master, origin/HEAD, master)
Author: Jian Li [pyguni@gmail.com]
AuthorDate: Wed Dec 30 14:13:18 2015 -0800
Commit: Ray Milkey [ray@onlab.us]
CommitDate: Thu Dec 31 06:18:19 2015 +0000

[ONOS-3601] Add unit test for MetricCodec and correct some typos

Case 1: Constructing test variables and building ONOS package - PASS

This test case is mainly for loading from params file, and pull and build the latest ONOS package

  • 1.1 Constructing test variables - PASS (tick)

Case 2: Starting up 1 node(s) ONOS cluster - PASS

Set up ONOS with 1 node(s) ONOS cluster

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Creating ONOS package - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Starting ONOS service - PASS (tick)
  • 2.6 Start ONOS cli - PASS (tick)

Case 10: Mininet with Linc-OE startup - PASS

Start opticalTest.py topology included with ONOS

  • 10.1 Starting mininet and LINC-OE - PASS (tick)

Case 21: Running Pingall - PASS

Use pingall to discover all hosts. Pingall is expected to fail.

  • 21.1 Discover Hosts through Pingall - PASS (tick)

Case 22: Discover Hosts with arping - PASS

Send arpings between all the hosts to discover and verify them

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology - PASS

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - PASS (tick)

Case 31: Install point intents between 2 packet layer device and ping the hosts - PASS

This testcase adds bidirectional point intents between 2 packet layer( mininet ) devices and ping mininet hosts

  • 31.1 Adding point intents - PASS (tick)
  • 31.2 Ping h1 and h5 - PASS (tick)

Case 32: Test add host intents between optical layer host - FAIL

Test host intents between 2 optical layer host

  • 32.1 Adding host intents to h1 and h2 - FAIL (error)
    • Some of the intents are not in INSTALLED state
  • 32.2 Removing host intents - FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

Stopping the current mininet topology to start up fresh

  • 14.1 Stopping Mininet Topology - PASS (tick)

Case 2: Starting up 3 node(s) ONOS cluster - PASS

Set up ONOS with 3 node(s) ONOS cluster

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Creating ONOS package - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Starting ONOS service - PASS (tick)
  • 2.6 Start ONOS cli - PASS (tick)

Case 10: Mininet with Linc-OE startup - PASS

Start opticalTest.py topology included with ONOS

  • 10.1 Starting mininet and LINC-OE - PASS (tick)

Case 21: Running Pingall - PASS

Use pingall to discover all hosts. Pingall is expected to fail.

  • 21.1 Discover Hosts through Pingall - PASS (tick)

Case 22: Discover Hosts with arping - PASS

Send arpings between all the hosts to discover and verify them

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology - PASS

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - PASS (tick)

Case 31: Install point intents between 2 packet layer device and ping the hosts - FAIL

This testcase adds bidirectional point intents between 2 packet layer( mininet ) devices and ping mininet hosts

  • 31.1 Adding point intents - FAIL (error)
    • Failed to add point intents
    • Skipping the rest of this case.

Case 32: Test add host intents between optical layer host - FAIL

Test host intents between 2 optical layer host

  • 32.1 Adding host intents to h1 and h2 - PASS (tick)
  • 32.2 Pinging h1 and h2 - PASS (tick)
  • 32.3 Removing host intents - FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

Stopping the current mininet topology to start up fresh

  • 14.1 Stopping Mininet Topology - PASS (tick)
  • No labels