Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 62 Next »

FUNCoptical at 09 Jan 2016 21:07:38

commit 24d9dc05bb78796b72315c588479a8c1e3db6ad6 (HEAD, origin/master, origin/HEAD, master)
Author: HIGUCHI Yuta [y-higuchi@ak.jp.nec.com]
AuthorDate: Fri Jan 8 22:12:10 2016 -0800
Commit: Gerrit Code Review [gerrit@onlab.us]
CommitDate: Sun Jan 10 03:06:07 2016 +0000

Documenting current limitation in OpenFlowOpticalSwitch.

Case 1: Constructing test variables and building ONOS package - PASS

This test case is mainly for loading from params file, and pull and build the latest ONOS package

  • 1.1 Constructing test variables - PASS (tick)

Case 2: Starting up 1 node(s) ONOS cluster - PASS

Set up ONOS with 1 node(s) ONOS cluster

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Creating ONOS package - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Starting ONOS service - PASS (tick)
  • 2.6 Start ONOS cli - PASS (tick)

Case 10: Mininet with Linc-OE startup - PASS

Start opticalTest.py topology included with ONOS

  • 10.1 Starting mininet and LINC-OE - PASS (tick)

Case 21: Running Pingall - PASS

Use pingall to discover all hosts. Pingall is expected to fail.

  • 21.1 Discover Hosts through Pingall - PASS (tick)

Case 22: Discover Hosts with arping - PASS

Send arpings between all the hosts to discover and verify them

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology - FAIL

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - FAIL (error)
    • ONOS incorrectly discovered the topology

Case 31: Install point intents between 2 packet layer device and ping the hosts - FAIL

This testcase adds bidirectional point intents between 2 packet layer( mininet ) devices and ping mininet hosts

  • 31.1 Adding point intents - FAIL (error)
    • Failed to add point intents
    • Skipping the rest of this case.

Case 32: Test add host intents between optical layer host - FAIL

Test host intents between 2 optical layer host

  • 32.1 Adding host intents to h1 and h2 - FAIL (error)
    • Some of the intents are not in INSTALLED state
  • 32.2 Removing host intents - FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

Stopping the current mininet topology to start up fresh

  • 14.1 Stopping Mininet Topology - PASS (tick)

Case 2: Starting up 3 node(s) ONOS cluster - PASS

Set up ONOS with 3 node(s) ONOS cluster

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Creating ONOS package - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Starting ONOS service - PASS (tick)
  • 2.6 Start ONOS cli - PASS (tick)

Case 10: Mininet with Linc-OE startup - PASS

Start opticalTest.py topology included with ONOS

  • 10.1 Starting mininet and LINC-OE - PASS (tick)

Case 21: Running Pingall - PASS

Use pingall to discover all hosts. Pingall is expected to fail.

  • 21.1 Discover Hosts through Pingall - PASS (tick)

Case 22: Discover Hosts with arping - PASS

Send arpings between all the hosts to discover and verify them

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology - FAIL

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - FAIL (error)
    • ONOS incorrectly discovered the topology

Case 31: Install point intents between 2 packet layer device and ping the hosts - FAIL

This testcase adds bidirectional point intents between 2 packet layer( mininet ) devices and ping mininet hosts

  • 31.1 Adding point intents - FAIL (error)
    • Failed to add point intents
    • Skipping the rest of this case.

Case 32: Test add host intents between optical layer host - FAIL

Test host intents between 2 optical layer host

  • 32.1 Adding host intents to h1 and h2 - FAIL (error)
    • Some of the intents are not in INSTALLED state
  • 32.2 Removing host intents - FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

Stopping the current mininet topology to start up fresh

  • 14.1 Stopping Mininet Topology - PASS (tick)
  • No labels