Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

SRSanity at 06 Sep 2019 19:31:03

SRSanity

commit 3a224b4fe93f66d000920f53f74c5b997b51545c (HEAD -] onos-2.2, origin/onos-2.2)
Author: Andrea Campanella [andrea@opennetworking.org]
AuthorDate: Thu Aug 29 16:51:14 2019 -0700
Commit: Andrea Campanella [andrea@opennetworking.org]
CommitDate: Wed Sep 4 15:54:35 2019 +0000

Adding wavlength tuning via GUI
--
(cherry picked from commit 6ac13ff484c70a9da6633e21dcb585c682b41c2f)

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spine and 1 Onos - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Stopping Mininet - PASS (tick)
  • 1.20 Copying karaf logs - PASS (tick)

Case 2: Bridging and Routing sanity test with 4x4 Leaf-spine and 1 Onos - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Stopping Mininet - PASS (tick)
  • 2.19 Copying karaf logs - PASS (tick)

Case 3: Bridging and Routing sanity test with single switch and 1 Onos - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.18 Stopping Mininet - PASS (tick)
  • 3.19 Copying karaf logs - PASS (tick)

Case 4: Bridging and Routing sanity test with 2x2 Leaf-spine and 3 Onos - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.18 Stopping Mininet - PASS (tick)
  • 4.19 Copying karaf logs - PASS (tick)

Case 5: Bridging and Routing sanity test with 4x4 Leaf-spine and 3 Onos - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Starting Mininet Topology - PASS (tick)
  • 5.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.14 Check whether all flow status are ADDED - PASS (tick)
  • 5.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

Case 6: Bridging and Routing sanity test with single switch and 3 Onos - FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Creating ONOS package - PASS (tick)
  • 6.5 Installing Atomix - PASS (tick)
  • 6.6 Installing ONOS package - PASS (tick)
  • 6.7 Set up ONOS secure SSH - PASS (tick)
  • 6.8 Checking ONOS service - PASS (tick)
  • 6.9 Starting ONOS CLI sessions - PASS (tick)
  • 6.10 Checking ONOS nodes - PASS (tick)
  • 6.11 Checking ONOS applications - PASS (tick)
  • 6.12 Starting Mininet Topology - PASS (tick)
  • 6.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 6.14 Check whether all flow status are ADDED - PASS (tick)
  • 6.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.18 Stopping Mininet - PASS (tick)
  • 6.19 Copying karaf logs - PASS (tick)
  • No labels