Have questions? Stuck? Please check our FAQ for some common questions and answers.

Optical Functionality Test Suite

Purpose 

This test ensures the functionality of optical application.

Test Overview 

This test uses a mininet optical topology included with the test files.  It has 2 hosts, 2 packet switches and 3 optical switches.

Test Strategy

The test heavily depends on correct loading of the optical topology.  The correct configuration for 

Test assumption

  • A test bench that has onos package deployed

  • Requires at least a single node cluster

  • Mininet topology included in the test dependency folder should run without errors

  • Stable ONOS build ( v1.3 and up )

  • LINC-OE installed

 
Test CasesPassing Criteria
Compare ONOS and Mininet Topologies
  • Topologies seen in Mininet and ONOS should match eachother
  • Same number of Hosts, Switches, and Links
Add and test bidirectional point intents
  • Intents can be installed between network nodes
  • Connectivity between hosts when intents are installed
  • Intent state is in INSTALLED state for each active instances
  • All devices that are being used are in ACTIVE state
  • Each active device is assigned to one master controller
  • Network topology from Mininet is equivalent to ONOS view for each active instances
  • Flows should be in its appropriate state before and after an event such as intent installation, rerouting flows etc.
  • System state is consistent to all active ONOS instance
  • Every match action given when adding intents should correctly stored in each of intents status
  • Network nodes ( switch and host ) information are consistent such as MAC, IPs, IDs, Ports.
  • Completely remove or purge all intents that have been installed
Add and test bidirectional host intents