Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 166 Next »

FUNCovsdbtest at 11 Nov 2016 22:05:23

commit a6f858966e36be5665f9273a90a15c4682413ad0 (HEAD, origin/master, origin/HEAD, master)
Author: Brian O'Connor [bocon@onlab.us]
AuthorDate: Fri Nov 11 13:18:47 2016 -0800
Commit: Brian O'Connor [bocon@onlab.us]
CommitDate: Fri Nov 11 17:29:33 2016 -0800

Moving core/security/BUCK to new, simplified format

Case 1: Setting up test environment - PASS

Setup the test environment including installing ONOS, start ONOS.

  • 1.1 Constructing test variables - No Result (warning)
  • 1.2 Uninstalling ONOS package - PASS (tick)
  • 1.3 Create cell file - No Result (warning)
  • 1.4 Apply cell to environment - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing ONOS package - PASS (tick)
  • 1.7 Starting ONOS service - PASS (tick)
  • 1.8 Starting ONOS CLI sessions - PASS (tick)
  • 1.9 App Ids check - PASS (tick)
  • 1.10 Install onos-ovsdb - PASS (tick)
  • 1.11 Install onos-app-vtn - PASS (tick)

Case 3: Test default br-int configuration and vxlan port - FAIL

onos create default br-int bridge and vxlan port on the ovsdb node

  • 3.1 ovsdb node 1 set ovs manager to 10.128.20.11 - PASS (tick)
  • 3.2 ovsdb node 2 set ovs manager to 10.128.20.11 - PASS (tick)
  • 3.3 Check ovsdb node 1 manager is 10.128.20.11 - PASS (tick)
  • 3.4 Check ovsdb node 2 manager is 10.128.20.11 - PASS (tick)
  • 3.5 Check default br-int bridge on ovsdb node 10.128.10.11 - FAIL (error)
    • onos add default bridge on the node 1 failed
  • 3.6 Check default br-int bridge on ovsdb node 10.128.20.11 - FAIL (error)
    • onos add default bridge on the node 2 failed
  • 3.7 Check default vxlan port on ovsdb node 10.128.10.11 - FAIL (error)
    • onos add default vxlan port on the node 1 failed
  • 3.8 Check default vxlan port on ovsdb node 10.128.20.11 - FAIL (error)
    • onos add default vxlan port on the node 2 failed

Case 4: - PASS

  • 4.1 ovsdb node 1 set ovs manager to 10.128.20.11 - PASS (tick)
  • 4.2 ovsdb node 2 set ovs manager to 10.128.20.11 - PASS (tick)
  • 4.3 Check ovsdb node 1 manager is 10.128.20.11 - PASS (tick)
  • 4.4 Check ovsdb node 2 manager is 10.128.20.11 - PASS (tick)
  • 4.5 Check ovsdb node 1 bridge br-int controller set to 10.128.20.11 - PASS (tick)
  • 4.6 Check ovsdb node 2 bridge br-int controller set to 10.128.20.11 - PASS (tick)
  • 4.7 Check onoscli devices have ovs 10.128.10.11 - PASS (tick)
  • 4.8 Check onoscli devices have ovs 10.128.20.11 - PASS (tick)

Case 2: Test ovsdb connection and teardown - PASS

Test ovsdb connection create and delete over ovsdb node and onos node

  • 2.1 Set ovsdb node manager - PASS (tick)
  • 2.2 Check ovsdb node manager is 10.128.20.11 - PASS (tick)
  • 2.3 Delete ovsdb node manager - PASS (tick)
  • 2.4 Check ovsdb node delete manager 10.128.20.11 - PASS (tick)

Case 5: - FAIL

  • 5.1 ovsdb node 1 set ovs manager to onos - PASS (tick)
  • 5.2 Check ovsdb node 1 manager is 10.128.20.11 - PASS (tick)
  • 5.3 Check ovsdb node 1 bridge br-int default flows on 10.128.10.11 - FAIL (error)
  • No labels