Case 1: High Availability tests - ONOS failures 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.24 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.25 Checking if ONOS CLI is ready - PASS (tick)
  • 1.26 Checking ONOS nodes - PASS (tick)
  • 1.27 Check number of topology elements - PASS (tick)
  • 1.28 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.29 Check whether all flow status are ADDED - PASS (tick)
  • 1.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.33 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 1.34 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.35 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.36 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.37 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.38 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 1.39 Checking if ONOS CLI is ready - PASS (tick)
  • 1.40 Checking ONOS nodes - PASS (tick)
  • 1.41 Check number of topology elements - PASS (tick)
  • 1.42 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.43 Check whether all flow status are ADDED - PASS (tick)
  • 1.44 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.45 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.46 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.47 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 1.48 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.49 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.50 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.51 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.52 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 1.53 Checking if ONOS CLI is ready - PASS (tick)
  • 1.54 Checking ONOS nodes - PASS (tick)
  • 1.55 Check number of topology elements - PASS (tick)
  • 1.56 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.57 Check whether all flow status are ADDED - PASS (tick)
  • 1.58 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.59 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.60 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.61 Stopping Mininet - PASS (tick)
  • 1.62 Copying karaf logs - PASS (tick)

Case 2: High Availability tests - ONOS random failures 2x2 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 2.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 2.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 2.23 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking ONOS nodes - PASS (tick)
  • 2.26 Check number of topology elements - PASS (tick)
  • 2.27 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.28 Check whether all flow status are ADDED - PASS (tick)
  • 2.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 2.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 2.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 2.32 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 2.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 2.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 2.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 2.37 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 2.38 Checking if ONOS CLI is ready - PASS (tick)
  • 2.39 Checking ONOS nodes - PASS (tick)
  • 2.40 Check number of topology elements - PASS (tick)
  • 2.41 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.42 Check whether all flow status are ADDED - PASS (tick)
  • 2.43 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 2.44 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 2.45 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 2.46 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 2.47 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.48 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 2.49 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 2.50 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 2.51 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 2.52 Checking if ONOS CLI is ready - PASS (tick)
  • 2.53 Checking ONOS nodes - PASS (tick)
  • 2.54 Check number of topology elements - PASS (tick)
  • 2.55 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.56 Check whether all flow status are ADDED - PASS (tick)
  • 2.57 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 2.58 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 2.59 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 2.60 Stopping Mininet - PASS (tick)
  • 2.61 Copying karaf logs - PASS (tick)

Case 3: High Availability tests - ONOS failures 4x4 Leaf-spine - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.18 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 3.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 3.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 3.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 3.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 3.23 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 3.24 Checking if ONOS CLI is ready - PASS (tick)
  • 3.25 Checking ONOS nodes - PASS (tick)
  • 3.26 Check number of topology elements - PASS (tick)
  • 3.27 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.28 Check whether all flow status are ADDED - PASS (tick)
  • 3.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 3.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 3.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 3.32 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 3.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 3.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 3.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 3.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 3.37 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 3.38 Checking if ONOS CLI is ready - PASS (tick)
  • 3.39 Checking ONOS nodes - PASS (tick)
  • 3.40 Check number of topology elements - PASS (tick)
  • 3.41 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.42 Check whether all flow status are ADDED - PASS (tick)
  • 3.43 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 3.44 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 3.45 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 3.46 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 3.47 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 3.48 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 3.49 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 3.50 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 3.51 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 3.52 Checking if ONOS CLI is ready - PASS (tick)
  • 3.53 Checking ONOS nodes - PASS (tick)
  • 3.54 Check number of topology elements - PASS (tick)
  • 3.55 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.56 Check whether all flow status are ADDED - PASS (tick)
  • 3.57 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 3.58 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 3.59 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 3.60 Stopping Mininet - PASS (tick)
  • 3.61 Copying karaf logs - PASS (tick)

Case 4: High Availability tests - ONOS random failures 4x4 Leaf-spine - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.18 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 4.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 4.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 4.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 4.23 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 4.24 Checking if ONOS CLI is ready - PASS (tick)
  • 4.25 Checking ONOS nodes - PASS (tick)
  • 4.26 Check number of topology elements - PASS (tick)
  • 4.27 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.28 Check whether all flow status are ADDED - PASS (tick)
  • 4.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 4.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 4.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 4.32 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 4.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 4.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 4.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 4.37 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 4.38 Checking if ONOS CLI is ready - PASS (tick)
  • 4.39 Checking ONOS nodes - PASS (tick)
  • 4.40 Check number of topology elements - PASS (tick)
  • 4.41 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.42 Check whether all flow status are ADDED - PASS (tick)
  • 4.43 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 4.44 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 4.45 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 4.46 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 4.47 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.48 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 4.49 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 4.50 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 4.51 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 4.52 Checking if ONOS CLI is ready - PASS (tick)
  • 4.53 Checking ONOS nodes - PASS (tick)
  • 4.54 Check number of topology elements - PASS (tick)
  • 4.55 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.56 Check whether all flow status are ADDED - PASS (tick)
  • 4.57 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 4.58 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 4.59 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 4.60 Stopping Mininet - PASS (tick)
  • 4.61 Copying karaf logs - PASS (tick)

Case 5: High Availability tests - ONOS failures and Switch failures 2x2 Leaf-spine - No Result