Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 22 Next »

SRDynamic at 23 Sep 2018 03:22:56

SRDynamic

commit 3e56d9fdbdfff775d877355b9dd7e3f9459b48c4 (HEAD -] master, origin/master, origin/HEAD)
Author: Charles Chan [rascov@gmail.com]
AuthorDate: Fri Sep 21 11:29:12 2018 -0700
Commit: Charles Chan [charles@opennetworking.org]
CommitDate: Sat Sep 22 00:05:48 2018 +0000

Fix serialization issue

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spineand 1 nodes. - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.19 Pushing new configuration - No Result (warning)
  • 1.20 Pushing new configuration - No Result (warning)
  • 1.21 Check whether the flow count is bigger than 140 - PASS (tick)
  • 1.22 Check whether all flow status are ADDED - PASS (tick)
  • 1.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.26 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE1 - PASS (tick)
  • 1.27 Stopping Mininet - PASS (tick)
  • 1.28 Copying karaf logs - PASS (tick)

Case 2: Bridging and Routing sanity test with 4x4 Leaf-spineand 1 nodes. - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.18 Pushing new configuration - No Result (warning)
  • 2.19 Pushing new configuration - No Result (warning)
  • 2.20 Check whether the flow count is bigger than 380 - PASS (tick)
  • 2.21 Check whether all flow status are ADDED - PASS (tick)
  • 2.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.25 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE2 - PASS (tick)
  • 2.26 Stopping Mininet - PASS (tick)
  • 2.27 Copying karaf logs - PASS (tick)

Case 3: Bridging and Routing sanity test with single switchand 1 nodes. - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.18 Pushing new configuration - No Result (warning)
  • 3.19 Pushing new configuration - No Result (warning)
  • 3.20 Check whether the flow count is bigger than 18 - PASS (tick)
  • 3.21 Check whether all flow status are ADDED - PASS (tick)
  • 3.22 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.25 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE3 - PASS (tick)
  • 3.26 Stopping Mininet - PASS (tick)
  • 3.27 Copying karaf logs - PASS (tick)

Case 4: Bridging and Routing sanity test with 2x2 Leaf-spineand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.18 Pushing new configuration - No Result (warning)
  • 4.19 Pushing new configuration - No Result (warning)
  • 4.20 Check whether the flow count is bigger than 140 - PASS (tick)
  • 4.21 Check whether all flow status are ADDED - PASS (tick)
  • 4.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.25 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE4 - PASS (tick)
  • 4.26 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 4.27 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.28 Removing host configuration - No Result (warning)
  • 4.29 Removing configuration - No Result (warning)
  • 4.30 Removing vlan configuration - No Result (warning)
  • 4.31 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.32 Check whether all flow status are ADDED - PASS (tick)
  • 4.33 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE4_After - PASS (tick)
  • 4.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_After - PASS (tick)
  • 4.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_After - PASS (tick)
  • 4.36 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE4_After - PASS (tick)
  • 4.37 Stopping Mininet - PASS (tick)
  • 4.38 Copying karaf logs - PASS (tick)

Case 5: Bridging and Routing sanity test with 4x4 Leaf-spineand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Starting Mininet Topology - PASS (tick)
  • 5.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.14 Check whether all flow status are ADDED - PASS (tick)
  • 5.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.18 Pushing new configuration - No Result (warning)
  • 5.19 Pushing new configuration - No Result (warning)
  • 5.20 Check whether the flow count is bigger than 380 - PASS (tick)
  • 5.21 Check whether all flow status are ADDED - PASS (tick)
  • 5.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.25 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE5 - PASS (tick)
  • 5.26 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 5.27 Check number of topology elements - PASS (tick)
  • 5.28 Removing host configuration - No Result (warning)
  • 5.29 Removing configuration - No Result (warning)
  • 5.30 Removing vlan configuration - No Result (warning)
  • 5.31 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.32 Check whether all flow status are ADDED - PASS (tick)
  • 5.33 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE5_After - PASS (tick)
  • 5.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_After - PASS (tick)
  • 5.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_After - PASS (tick)
  • 5.36 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE5_After - PASS (tick)
  • 5.37 Stopping Mininet - PASS (tick)
  • 5.38 Copying karaf logs - PASS (tick)

Case 6: Bridging and Routing sanity test with single switchand 3 nodes. Also, killing the first Onos and removing the host cfg. - FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Creating ONOS package - PASS (tick)
  • 6.5 Installing Atomix - PASS (tick)
  • 6.6 Installing ONOS package - PASS (tick)
  • 6.7 Set up ONOS secure SSH - PASS (tick)
  • 6.8 Checking ONOS service - PASS (tick)
  • 6.9 Starting ONOS CLI sessions - PASS (tick)
  • 6.10 Checking ONOS nodes - PASS (tick)
  • 6.11 Checking ONOS applications - PASS (tick)
  • 6.12 Starting Mininet Topology - PASS (tick)
  • 6.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 6.14 Check whether all flow status are ADDED - PASS (tick)
  • 6.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - PASS (tick)
  • 6.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - PASS (tick)
  • 6.18 Pushing new configuration - No Result (warning)
  • 6.19 Pushing new configuration - No Result (warning)
  • 6.20 Check whether the flow count is bigger than 20 - PASS (tick)
  • 6.21 Check whether all flow status are ADDED - PASS (tick)
  • 6.22 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - PASS (tick)
  • 6.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - PASS (tick)
  • 6.25 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE6 - PASS (tick)
  • 6.26 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 6.27 Check number of topology elements - PASS (tick)
  • 6.28 Removing host configuration - No Result (warning)
  • 6.29 Removing configuration - No Result (warning)
  • 6.30 Removing vlan configuration - No Result (warning)
  • 6.31 Check whether the flow count is bigger than 15 - PASS (tick)
  • 6.32 Check whether all flow status are ADDED - PASS (tick)
  • 6.33 Verify full connectivity for [u'h1', u'h2', 'in1', 'out1'] with tag CASE6_After - PASS (tick)
  • 6.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6_After - PASS (tick)
  • 6.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6_After - PASS (tick)
  • 6.36 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE6_After - PASS (tick)
  • 6.37 Stopping Mininet - PASS (tick)
  • 6.38 Copying karaf logs - PASS (tick)
  • No labels