Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 12 Next »

SRSwitchFailure at 08 Nov 2019 20:05:54

SRSwitchFailure

commit 089f4ae079fd99d9187f092bd94306e56dfdcb83 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pier [pier@opennetworking.org]
AuthorDate: Thu Apr 25 18:51:51 2019 +0200
Commit: pier [pier@opennetworking.org]
CommitDate: Fri Nov 8 09:40:50 2019 +0100

Improves link up handling

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 1.24 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.25 Check whether all flow status are ADDED - PASS (tick)
  • 1.26 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.28 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.29 Stopping Mininet - PASS (tick)
  • 1.30 Copying karaf logs - PASS (tick)

Case 2: Switch Failure test with 4x4 Leaf-spine and 1 Onos - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 2.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 2.23 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.24 Check whether all flow status are ADDED - PASS (tick)
  • 2.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.28 Stopping Mininet - PASS (tick)
  • 2.29 Copying karaf logs - PASS (tick)

Case 4: Switch Failure test with 2x2 Leaf-spine and 3 Onos - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 4.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Failure - FAIL (error)
    • IP connectivity failed
  • 4.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Failure - FAIL (error)
    • IP connectivity failed
  • 4.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Failure - FAIL (error)
    • IP connectivity failed
  • 4.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 4.23 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.24 Check whether all flow status are ADDED - PASS (tick)
  • 4.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.28 Stopping Mininet - PASS (tick)
  • 4.29 Copying karaf logs - PASS (tick)

Case 5: Switch Failure test with 4x4 Leaf-spine and 3 Onos - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Starting Mininet Topology - PASS (tick)
  • 5.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.14 Check whether all flow status are ADDED - PASS (tick)
  • 5.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.18 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • 5.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.22 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 5.23 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.24 Check whether all flow status are ADDED - PASS (tick)
  • 5.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.28 Stopping Mininet - PASS (tick)
  • 5.29 Copying karaf logs - PASS (tick)
  • No labels